Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Dent ; 135: 104555, 2023 08.
Article in English | MEDLINE | ID: mdl-37263410

ABSTRACT

OBJECTIVES: Musculoskeletal disorders (MSDs), particularly neck and low back pain, constitute a major public health issue worldwide with a heavy morbidity and economic impact. However, the relationships between the stomatognathic system and MSDs are subjected to debate, data sorely lacking. The study objective was to investigate the association between bruxism (BR) and MSDs. Secondary objective includes the study of the association between tooth wear (TW) and MSDs. METHODS: This is a cross-sectional study on 425 participants frequenting a university dental clinic. The presence of MSDs was evaluated with the standardized Nordic questionnaire. The sleep and awake BR assessments were based on clinical examination and self-report. TW was measured with the BEWE index. Socio-demographic factors, medical history, life habits and stress were analyzed as potential confounding variables. RESULTS: 91% of patients reported at least one MSD during the preceding 12 months and 75.5% were diagnosed as bruxers. In multivariate analyses, BR was associated with a 5-fold increased risk of prevalent MSD (OR=5.88 (2.7-12.5), p<0.0001). Regarding TW, for a one-point increase in anterior BEWE score, the risk to present an MSD was increased by 53% (OR=1.53 (1.12-2.08), p = 0.0076). Moreover, BR was independently associated with neck, shoulder, upper back, low back, hip & thigh and knee MSDs. Anterior TW was independently associated with neck, low back and hip & thigh MSDs, and global TW with knee MSDs. CONCLUSIONS: BR and TW were shown to be associated with MSDs. The cause-and-effect relationships between those factors needs to be analyzed to optimize prevention and therapeutic care. CLINICAL SIGNIFICANCE: Results suggest that the body is a whole, a balanced muscular system, where every part constitutes a link of the chain. MSDs management and prevention may require a multidisciplinary team approach and future perspectives include defining the dentist's role in this context, particularly with respect to BR diagnostic and treatment.


Subject(s)
Bruxism , Musculoskeletal Diseases , Occupational Diseases , Tooth Attrition , Humans , Bruxism/complications , Bruxism/epidemiology , Cross-Sectional Studies , Occupational Diseases/prevention & control , Musculoskeletal Diseases/prevention & control , Surveys and Questionnaires , Risk Factors , Prevalence
2.
J Oral Rehabil ; 50(10): 1110-1165, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37147932

ABSTRACT

BACKGROUND: Tooth wear (TW) prevalence is high and increasing and has important consequences on the patient's quality of life. Knowledge of risk factors is crucial to promote diagnosis, prevention strategies and timely interceptive treatment. Many studies have identified TW risk factors. OBJECTIVE: This scoping review aims to map and describe suspected available factors associated with TW in permanent dentition based on quantitative measurement. METHODS: The scoping review was conducted using the PRISMA extension of the Scoping Reviews checklist. The search was conducted in October 2022 from the Medline® (PubMed® interface) and Scopus® databases. Two independent reviewers selected and characterised the studies. RESULTS: 2702 articles were identified for assessment of titles and abstracts, and 273 articles were included in the review. The results show a need to standardise TW measurement indices and the study design. The included studies highlighted various factors, classified into nine domains: sociodemographic factors, medical history, drinking habits, eating habits, oral hygiene habits, dental factors, bruxism and temporomandibular disorders, behavioural factors, and stress. Results related to chemical TW (erosion) risk factors underline the importance of eating disorders, gastroesophageal reflux and lifestyle, particularly drinking and eating behaviours, which supports developing public health information campaigns and interventions. Besides chemical, this review identifies evidence of several mechanical TW risk factors, such as toothbrushing and bruxism; the influence of this last factor needs to be further explored. CONCLUSIONS: TW management and prevention require a multidisciplinary approach. Dentists are in the first line to detect associated diseases such as reflux or eating disorders. Consequently, practitioners' information and guideline diffusion should be promoted, and a TW risk factors checklist (the ToWeR checklist) is proposed to help diagnostic approaches.


Subject(s)
Bruxism , Gastroesophageal Reflux , Tooth Attrition , Tooth Erosion , Tooth Wear , Humans , Bruxism/complications , Bruxism/epidemiology , Dentition, Permanent , Tooth Erosion/epidemiology , Tooth Erosion/etiology , Tooth Erosion/therapy , Quality of Life , Tooth Wear/epidemiology , Tooth Wear/etiology , Tooth Attrition/complications , Tooth Attrition/epidemiology , Risk Factors , Gastroesophageal Reflux/complications
3.
J Dent ; 63: 1-7, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28456557

ABSTRACT

OBJECTIVES: The objectives of the present study were to (1) retrospectively evaluate documented cases of ceramic and composite endocrowns performed using immediate dentin sealing (IDS); (2) correlate failures with clinical parameters such as tooth preparation characteristics and occlusal parameters. METHODS: 99 documented cases of endocrowns were evaluated after a mean observation period of 44.7±34.6months. A classification of restorations was established in function of the level of damage of residual tooth tissues after preparation, from 1 to 3. Evaluation was performed according to FDI criteria and endodontic outcomes were analyzed. Occlusal risk factors were examined and fractographic analysis was performed in case of fracture. RESULTS: 48.4% of patients were shown to present occlusal risk factors. 75.8% of restorations were Class 3 endocrowns. 56.6% were performed on molars, 41.4% on premolars and 2.0% on canines. 84.8% were performed in lithium-disilicate glass-ceramic and 12.1% in Polymer-Infiltrated Ceramic Network (PICN) material. The survival and success rates of endocrowns were 99.0% and 89.9% respectively, while the 10-year Kaplan-Meier estimated survival and success rates were 98.8% and 54.9% respectively. Ten failures were detected: periodontal disease (n=3), endocrown debonding (n=2), minor chipping (n=2), caries recurrence (n=2) and major fractures (n=1). Due to the reduced amount of failures, no statistical correlation could be established with clinical parameters. CONCLUSIONS: Endocrowns were shown to constitute a reliable approach to restore severely damaged molars and premolars, even in the presence of extensive coronal tissue loss or occlusal risk factors, such as bruxism or unfavorable occlusal relationships. CLINICAL SIGNIFICANCE: Practitioners should consider the endocrown instead of the post and core approach to restore severely damaged non-vital posterior teeth. This minimally invasive solution reduces the risk of catastrophic failures and is easily performed. The use of IDS procedure and lithium-disilicate glass-ceramic as prosthesis material gave very good results.


Subject(s)
Ceramics , Crowns , Dental Restoration Failure , Dental Restoration, Permanent , Resin Cements , Adult , Aged , Aged, 80 and over , Bicuspid/pathology , Dental Marginal Adaptation , Dental Porcelain , Female , Humans , Male , Malocclusion , Masticatory Muscles , Materials Testing , Middle Aged , Molar/pathology , Post and Core Technique , Retrospective Studies , Risk Factors , Survival Analysis , Tooth Fractures , Tooth Preparation
4.
Dent Mater ; 33(3): 333-343, 2017 03.
Article in English | MEDLINE | ID: mdl-28159322

ABSTRACT

OBJECTIVE: Biocompatibility of polymer-infiltrated-ceramic-network (PICN) materials, a new class of CAD-CAM composites, is poorly explored in the literature, in particular, no data are available regarding Human Gingival Keratinocytes (HGK). The first objective of this study was to evaluate the in vitro biocompatibility of PICNs with HGKs in comparison with other materials typically used for implant prostheses. The second objective was to correlate results with PICN monomer release and indirect cytotoxicity. METHODS: HGK attachment, proliferation and spreading on PICN, grade V titanium (Ti), yttrium zirconia (Zi), lithium disilicate glass-ceramic (eM) and polytetrafluoroethylene (negative control) discs were evaluated using a specific insert-based culture system. For PICN and eM samples, monomer release in the culture medium was quantified by high performance liquid chromatography and indirect cytotoxicity tests were performed. RESULTS: Ti and Zi exhibited the best results regarding HGK viability, number and coverage. eM showed inferior results while PICN showed statistically similar results to eM but also to Ti regarding cell number and to Ti and Zi regarding cell viability. No monomer release from PICN discs was found, nor indirect cytotoxicity, as for eM. SIGNIFICANCE: The results confirmed the excellent behavior of Ti and Zi with gingival cells. Even if polymer based, PICN materials exhibited intermediate results between Ti-Zi and eM. These promising results could notably be explained by PICN high temperature-high pressure (HT-HP) innovative polymerization mode, as confirmed by the absence of monomer release and indirect cytotoxicity.


Subject(s)
Ceramics , Dental Porcelain , Keratinocytes , Polymers , Computer-Aided Design , Gingiva , Humans , Materials Testing , Zirconium
5.
Dent Mater ; 32(9): 1152-64, 2016 09.
Article in English | MEDLINE | ID: mdl-27402299

ABSTRACT

OBJECTIVES: Polymer-infiltrated-ceramic-network (PICN) materials constitute an innovative class of CAD-CAM materials offering promising perspectives in prosthodontics, but no data are available in the literature regarding their biological properties. The objective of the present study was to evaluate the in vitro biocompatibility of PICNs with human gingival fibroblasts (HGFs) in comparison with materials typically used for implant prostheses and abutments. METHODS: HGF attachment, proliferation and spreading on discs made of PICN, grade V titanium (Ti), yttrium zirconia (Zi), lithium disilicate glass-ceramic (eM) and polytetrafluoroethylene (negative control), were evaluated using a specific insert-based culture system (IBS-R). Sample surface properties were characterized by XPS, contact angle measurement, profilometry and SEM. RESULTS: Ti and Zi gave the best results regarding HGF viability, morphology, number and coverage increase with time in comparison with the negative control, while PICN and eM gave intermediate results, cell spreading being comparable for PICN, Ti, Zi and eM. Despite the presence of polymers and their related hydrophobicity, PICN exhibited comparable results to glass-ceramic materials, which could be explained by the mode of polymerization of the monomers. SIGNIFICANCE: The results of the present study confirm that the currently employed materials, i.e. Ti and Zi, can be considered to be the gold standard of materials in terms of HGF behavior, while PICN gave intermediate results comparable to eM. The impact of the present in vitro results needs to be further investigated clinically, particularly in the view of the utilization of PICNs for prostheses on bone-level implants.


Subject(s)
Ceramics , Computer-Aided Design , Dental Porcelain , Gingiva/cytology , Polymers , Fibroblasts , Humans , Materials Testing , Surface Properties , Zirconium
6.
Cytotechnology ; 68(6): 2437-2448, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27015830

ABSTRACT

In vitro studies about biomaterials biological properties are essential screening tests. Yet cell cultures encounter difficulties related to cell retention on material surface or to the observation of both faces of permeable materials. The objective of the present study was to develop a reliable in vitro method to study cell behavior on rigid and flexible/permeable biomaterials elaborating two specific insert-based systems (IBS-R and IBS-F respectively). IBS-R was designed as a specific cylindrical polytetrafluoroethylene (PTFE) system to evaluate attachment, proliferation and morphology of human gingival fibroblasts (HGFs) on grade V titanium and lithium disilicate glass-ceramic discs characteristics of dental prostheses. The number of cells, their covering on discs and their morphology were determined from MTS assays and microscopic fluorescent images after 24, 48 and 72 h. IBS-F was developed as a two components system to study HGFs behavior on guided bone regeneration polyester membranes. The viability and the membrane barrier effect were evaluated by metabolic MTS assays and by scanning electron microscopy. IBS-R and IBS-F were shown to promote (1) easy and rapid handling; (2) cell retention on biomaterial surface; (3) accurate evaluation of the cellular proliferation, spreading and viability; (4) use of non-toxic material. Moreover IBS-F allowed the study of the cell migration through degradable membranes, with an access to both faces of the biomaterial and to the bottom of culture wells for medium changing.

7.
J Oral Implantol ; 41(6): 693-9, 2015 Dec.
Article in English | MEDLINE | ID: mdl-24766161

ABSTRACT

Narrow-diameter implants (NDIs) are increasingly produced and used in implant dentistry, especially since the introduction of new, more resistant materials. The objective of the present study was to evaluate the clinical performance of NDIs (3.3 mm) placed in thin alveolar crests. Twenty consecutive patients needing implant-supported fixed partial dentures and presenting an alveolar thickness ≤6 mm were treated with 1 or several NDIs. The surgical protocol was chosen according to the clinical situation: (1) flapless, (2) mini-cervical flap, (3) wide flap, (4) wide flap + guided bone regeneration (GBR). Implants were immediately loaded if the primary stability was higher than 20 Ncm. Implant survival and success, prosthodontic success rates, and patient-centered outcomes were evaluated after a follow-up period of 1 year. A total of 39 implants were placed in 20 patients, 12 and 27 implants in the anterior regions and in the posterior mandible, respectively. All but 1 implant reached an insertion torque higher than 20 Ncm and were loaded within 48 hours. The implant survival and success rates both reached 94.7%. The need for GBR was avoided in 60% of the implant sites. The mean peri-implant bone remodeling after a follow-up period of 1 year was -0.35 mm at the implant level. Peri-implant bone remodeling was higher in the posterior region, when the alveolar crest was thinner than 4 mm and GBR was required in addition. In conclusion, use of NDIs to restore partial edentation in sites with limited horizontal thickness seems to be an effective treatment option that prevented GBR in the majority of the present cases. Immediate provisionalization of NDIs does not seem to impair the results.


Subject(s)
Alveolar Bone Loss , Dental Implantation, Endosseous , Dental Implants , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Follow-Up Studies , Humans , Maxilla , Prospective Studies , Treatment Outcome
8.
J Prosthet Dent ; 105(4): 249-55, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21458650

ABSTRACT

STATEMENT OF PROBLEM: Various CAD/CAM processes are commercially available to manufacture zirconia copings. Comparative data on their performance in terms of fit are needed. PURPOSE: The purpose of this in vitro study was to compare the internal and marginal fit of single tooth zirconia copings manufactured with a CAD/CAM process (Procera; Nobel Biocare) and a mechanized manufacturing process (Ceramill; Amann Girrbach). MATERIAL AND METHODS: Abutments (n=20) prepared in vivo for ceramic crowns served as a template for manufacturing both Procera and Ceramill zirconia copings. Copings were manufactured and cemented (Clearfil Esthetic Cement; Kuraray) on epoxy replicas of stone cast abutments. Specimens were sectioned. Nine measurements were performed for each coping. Over- and under-extended margins were evaluated. Comparisons between the 2 processes were performed with a generalized linear mixed model (α=.05). RESULTS: Internal gap values between Procera and Ceramill groups were not significantly different (P=.13). The mean marginal gap (SD) for Procera copings (51(50) µm) was significantly smaller than for Ceramill (81(66) µm) (P<.005). The percentages of over- and under-extended margins were 43% and 57% for Procera respectively, and 71% and 29% for Ceramill. CONCLUSIONS: Within the limitations of this in vitro study, the marginal fit of Procera copings was significantly better than that of Ceramill copings. Furthermore, Procera copings showed a smaller percentage of over-extended margins than did Ceramill copings.


Subject(s)
Computer-Aided Design , Crowns/standards , Dental Abutments/standards , Dental Marginal Adaptation , Dental Prosthesis Design , Dental Porcelain , Humans , Tooth, Artificial/classification , Tooth, Artificial/standards , Zirconium
SELECTION OF CITATIONS
SEARCH DETAIL
...