Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Eur Radiol ; 24(6): 1229-38, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24668010

ABSTRACT

OBJECTIVES: Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. METHODS: We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). RESULTS: Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). CONCLUSIONS: Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. KEY POINTS: Fixed threshold bolus tracking is suitable for coronary 320-row CT angiography. Manual fast start bolus tracking can reduce contrast agent volumes. Manual fast start and fixed threshold initiation achieve good image quality. Fixed threshold bolus tracking achieves a more reliable contrast bolus position.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Contrast Media , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
2.
J Am Coll Cardiol ; 62(16): 1476-85, 2013 Oct 15.
Article in English | MEDLINE | ID: mdl-23792193

ABSTRACT

OBJECTIVES: This study sought to determine whether adding myocardial computed tomography perfusion (CTP) to computed tomography angiography (CTA) improves diagnostic performance for coronary stents. BACKGROUND: CTA of coronary stents has been limited by nondiagnostic studies caused by metallic stent material and coronary motion. METHODS: CTA and CTP were performed in 91 consecutive patients with stents before quantitative coronary angiography, the reference standard for obstructive stenosis (≥50%). If a coronary stent or vessel was nondiagnostic on CTA, adenosine stress CTP in the corresponding myocardial territory was read for combined CTA/CTP. RESULTS: Patients had an average of 2.5 ± 1.8 coronary stents (1 to 10), with a diameter of 3.0 ± 0.5 mm. Significantly more patients were nondiagnostic for stent assessment by CTA (22%; mainly due to metal artifacts [75%] or motion [25%]) versus CTP (1%; p < 0.001; severe angina precluded CTP in 1 case). The per-patient diagnostic accuracy of CTA/CTP for stents (87%, 95% confidence interval [CI]: 78% to 93%) was significantly higher than that of CTA alone (71%, 95% CI: 61% to 80%; p < 0.001), mainly because nondiagnostic examinations were significantly reduced (p < 0.001). In the analysis of any coronary artery disease, diagnostic accuracy and nondiagnostic rate were also significantly improved by the addition of CTP (p < 0.001). CTA/CTP (7.9 ± 2.8 mSv) had a significantly lower effective radiation dose than angiography (9.5 ± 5.1 mSv; p = 0.005). The area under the receiver-operating characteristic curve for CTA/CTP (0.82, 95% CI: 0.69 to 0.95) was superior to that for CTA (0.69, 95% CI: 0.57 to 0.82; p < 0.001) in identifying patients requiring stent revascularization. CONCLUSIONS: Combined coronary CTA and myocardial CTP improves diagnosis of CAD and in-stent restenosis in patients with stents compared with CTA alone. (Coronary Artery Stent Evaluation With 320-Slice Computed Tomography-The CArS 320 Study [CARS-320]; NCT00967876).


Subject(s)
Coronary Artery Disease/surgery , Coronary Restenosis , Myocardial Revascularization/adverse effects , Postoperative Complications/diagnosis , Stents/adverse effects , Aged , Comparative Effectiveness Research , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Female , Humans , Male , Middle Aged , Myocardial Perfusion Imaging/methods , Myocardial Revascularization/instrumentation , Myocardial Revascularization/methods , Outcome and Process Assessment, Health Care , Prospective Studies , ROC Curve , Radiation Monitoring , Tomography, X-Ray Computed/methods
3.
J Am Coll Cardiol ; 59(21): 1897-907, 2012 May 22.
Article in English | MEDLINE | ID: mdl-22595410

ABSTRACT

OBJECTIVES: This study was designed to compare the accuracy of 64-row contrast computed tomography (CT), invasive cineventriculography (CVG), 2-dimensional echocardiography (2D Echo), and 3-dimensional echocardiography (3D Echo) for left ventricular (LV) function assessment with magnetic resonance imaging (MRI). BACKGROUND: Cardiac function is an important determinant of therapy and is a major predictor for long-term survival in patients with coronary artery disease. A number of methods are available for assessment of function, but there are limited data on the comparison between these multiple methods in the same patients. METHODS: A total of 36 patients prospectively underwent 64-row CT, CVG, 2D Echo, 3D Echo, and MRI (as the reference standard). Global and regional LV wall motion and ejection fraction (EF) were measured. In addition, assessment of interobserver agreement was performed. RESULTS: For the global EF, Bland-Altman analysis showed significantly higher agreement between CT and MRI (p < 0.005, 95% confidence interval: ±14.2%) than for CVG (±20.2%) and 3D Echo (±21.2%). Only CVG (59.5 ± 13.9%, p = 0.03) significantly overestimated EF in comparison with MRI (55.6 ± 16.0%). CT showed significantly better agreement for stroke volume than 2D Echo, 3D Echo, and CVG. In comparison with MRI, CVG-but not CT-significantly overestimated the end-diastolic volume (p < 0.001), whereas 2D Echo and 3D Echo significantly underestimated the EDV (p < 0.05). There was no significant difference in diagnostic accuracy (range: 76% to 88%) for regional LV function assessment between the 4 methods when compared with MRI. Interobserver agreement for EF showed high intraclass correlation for 64-row CT, MRI, 2D Echo, and 3D Echo (intraclass correlation coefficient >0.8), whereas agreement was lower for CVG (intraclass correlation coefficient = 0.58). CONCLUSIONS: 64-row CT may be more accurate than CVG, 2D Echo, and 3D Echo in comparison with MRI as the reference standard for assessment of global LV function.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Tomography, X-Ray Computed/methods , Ventricular Function, Left , Cineradiography , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results
4.
Eur Radiol ; 22(8): 1641-50, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22527372

ABSTRACT

OBJECTIVES: To prospectively compare induced DNA double-strand breaks by cardiac computed tomography (CT) and conventional coronary angiography (CCA). METHODS: 56 patients with suspected coronary artery disease were randomised to undergo either CCA or cardiac CT. DNA double-strand breaks were assessed in fluorescence microscopy of blood lymphocytes as indicators of the biological effects of radiation exposure. Radiation doses were estimated using dose-length product (DLP) and dose-area product (DAP) with conversion factors for CT and CCA, respectively. RESULTS: On average there were 0.12 ± 0.06 induced double-strand breaks per lymphocyte for CT and 0.29 ± 0.18 for diagnostic CCA (P < 0.001). This relative biological effect of ionising radiation from CCA was 1.9 times higher (P < 0.001) than the effective dose estimated by conversion factors would have suggested. The correlation between the biological effects and the estimated radiation doses was excellent for CT (r = 0.951, P < 0.001) and moderate to good for CCA (r = 0.862, P < 0.001). One day after radiation, a complete repair of double-strand breaks to background levels was found in both groups. CONCLUSIONS: Conversion factors may underestimate the relative biological effects of ionising radiation from CCA. DNA double-strand break assessment may provide a strategy for individualised assessments of radiation. KEY POINTS: • Radiation dose causes concern for both conventional coronary angiography and cardiac CT. • Estimations of the biological effects of ionising radiation may become feasible. • Fewer DNA double-strand breaks are induced by cardiac CT than CCA. • Conversion factors may underestimate the relative effects of ionising radiation from CCA.


Subject(s)
Coronary Angiography/adverse effects , DNA Breaks, Double-Stranded , Heart/diagnostic imaging , Tomography, X-Ray Computed/adverse effects , Aged , Cardiac Catheterization , Dose-Response Relationship, Radiation , Female , Humans , Lymphocytes/diagnostic imaging , Lymphocytes/radiation effects , Male , Microscopy, Fluorescence/methods , Middle Aged , Radiation Dosage , Radiation, Ionizing , Relative Biological Effectiveness
5.
Acta Radiol ; 53(3): 285-91, 2012 Apr 01.
Article in English | MEDLINE | ID: mdl-22371622

ABSTRACT

BACKGROUND: In amyotrophic lateral sclerosis (ALS) patients with respiratory impairment and/or advanced disease, performing even mild sedation - as is usually necessary for percutaneous endoscopic gastrostomy (PEG) placements - is fraught with risk. These patients are often referred to Interventional Radiology for alternative percutaneous gastrostomy tube placement options. PURPOSE: To report our experience with CT fluoroscopy-guided percutaneous gastrostomy with a novel loop gastropexy and peel-away sheath trocar technique in ALS patients as an alternative to endoscopic techniques. MATERIAL AND METHODS: A consecutive series of 31 amyotrophic lateral sclerosis patients in whom endoscopic gastrostomy was considered too dangerous or impossible to perform underwent CT-guided percutaneous gastropexy and gastrostomy and prospective follow-up. All procedures were performed with a 15 FR Freka® Pexact gastrostomy kit, a 16-row CT scanner (Aquilion 16) and single shot CT fluoroscopy mode. RESULTS: The procedure was performed successfully in 30 of 31 patients (20 men, 11 women; median age 60 years, range 38-80 years). In the remaining case the stomach was punctured under CT fluoroscopy and CO2 insufflation was initiated thereafter, leading to successful gastrostomy without prior gastropexy and without further adverse events during follow-up. Two patients reported unproblematic exchange of a balloon tube due to skin irritations with no further adverse events. One patient reported accidental displacement of an exchanged new balloon tube in domestic environment due to balloon leakage: A new balloon tube was easily re-inserted in a hospital the same day. No serious adverse events such as peritonitis, persistent local bleeding, systemic blood loss, or any local infection requiring surgical intervention were observed. Until August 11, 2011 follow-up resulted in 7473 cumulative gastrostomy-days from the date of first placement. CONCLUSION: Initial results suggest that the described technique under CT guidance is feasible and safe and may especially be advantageous in cases where endoscopic gastrostomy and sedation are contraindicated.


Subject(s)
Amyotrophic Lateral Sclerosis/surgery , Gastropexy/methods , Gastrostomy/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Amyotrophic Lateral Sclerosis/diagnostic imaging , Female , Fluoroscopy/methods , Follow-Up Studies , Gastropexy/instrumentation , Gastrostomy/instrumentation , Humans , Male , Middle Aged , Prospective Studies , Radiography, Interventional/methods , Stomach/diagnostic imaging , Stomach/surgery , Surgical Instruments , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...