Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 55(10): 2718-23, 2016 04 01.
Article in English | MEDLINE | ID: mdl-27139677

ABSTRACT

A key feature of Alvarez lenses is that they may be tuned in focal length using lateral rather than axial translation, thus reducing the overall length of a focus-tunable optical system. Nevertheless the bulk of classical microsystems actuators limits further miniaturization. We present here a new, ultrathin focus-tunable Alvarez lens fabricated using molding techniques and actuated using liquid crystal elastomer (LCE) artificial muscle actuators. The large deformation generated by the LCE actuators permits the integration of the actuators in-plane with the mechanical and optical system and thus reduces the device thickness to only 1.6 mm. Movement of the Alvarez lens pair of 178 µm results in a focal length change of 3.3 mm, based on an initial focal length of 28.4 mm. This design is of considerable interest for realization of ultraflat focus-tunable and zoom systems.


Subject(s)
Computer-Aided Design , Lens, Crystalline , Miniaturization , Equipment Design , Lenses , Muscles
2.
Appl Opt ; 54(4): 839-47, 2015 Feb 01.
Article in English | MEDLINE | ID: mdl-25967795

ABSTRACT

The photoluminescence intensity of group III nitrides, nanowires, and heterostructures (NWHs) strongly depends on the environmental H(2) and O(2) concentration. We used this opto-chemical transducer principle for the realization of a gas detector. To make this technology prospectively available to commercial gas-monitoring applications, a large-scale laboratory setup was miniaturized. To this end the gas-sensitive NWHs were integrated with electro-optical components for optical addressing and read out within a compact and robust sensor system. This paper covers the entire realization process of the device from its conceptual draft and optical design to its fabrication and assembly. The applied approaches are verified with intermediate results of profilometric characterizations and optical performance measurements of subsystems. Finally the gas-sensing capabilities of the integrated detector are experimentally proven and optimized.

3.
Opt Lett ; 39(13): 3986-8, 2014 Jul 01.
Article in English | MEDLINE | ID: mdl-24978788

ABSTRACT

We propose a hybrid optical-digital imaging system that can provide high-resolution retinal images without wavefront sensing or correction of the spatial and dynamic variations of eye aberrations. A methodology based on wavefront coding is implemented in a fundus camera in order to obtain a high-quality image of retinal detail. Wavefront-coded systems rely simply on the use of a cubic-phase plate in the pupil of the optical system. The phase element is intended to blur images in such a way that invariance to optical aberrations is achieved. The blur is then removed by image postprocessing. Thus, the system can provide high-resolution retinal images, avoiding all the optics needed to sense and correct ocular aberration, i.e., wavefront sensors and deformable mirrors.


Subject(s)
Diagnostic Techniques, Ophthalmological , Optical Imaging/methods , Retina/anatomy & histology , Aberrometry/instrumentation , Aberrometry/methods , Corneal Wavefront Aberration/diagnosis , Diagnostic Techniques, Ophthalmological/instrumentation , Humans , Optical Devices , Optical Imaging/instrumentation , Optical Phenomena , Retina/pathology , Retinal Diseases/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...