Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Sci Rep ; 14(1): 931, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38195807

ABSTRACT

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

2.
Rev Sci Instrum ; 94(1): 014701, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36725565

ABSTRACT

We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of ±10 and ±250 mA on three independent channels with 16-bit resolution. Both devices feature a narrow 1/f noise bandwidth of 1 Hz, enabling magnetic field manipulation for high-performance OPMs. They exhibit a low noise of 146 pA/Hz and 4.1 nA/Hz, which translates to 15 and 16 ppb/Hz noise relative to full scale.

3.
Rev Sci Instrum ; 93(9): 091101, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36182455

ABSTRACT

Laser cooled atoms have proven transformative for precision metrology, playing a pivotal role in state-of-the-art clocks and interferometers and having the potential to provide a step-change in our modern technological capabilities. To successfully explore their full potential, laser cooling platforms must be translated from the laboratory environment and into portable, compact quantum sensors for deployment in practical applications. This transition requires the amalgamation of a wide range of components and expertise if an unambiguously chip-scale cold atom sensor is to be realized. We present recent developments in cold-atom sensor miniaturization, focusing on key components that enable laser cooling on the chip-scale. The design, fabrication, and impact of the components on sensor scalability and performance will be discussed with an outlook to the next generation of chip-scale cold atom devices.

4.
Opt Express ; 28(7): 9072-9081, 2020 Mar 30.
Article in English | MEDLINE | ID: mdl-32225520

ABSTRACT

We optically assess Fresnel zone plates (FZPs) that are designed to guide cold atoms. Imaging of various ring patterns produced by the FZPs gives an average RMS error in the brightest part of the ring of 3% with respect to trap depth. This residue is attributed to the imaging system, incident beam shape and FZP manufacturing tolerances. Axial propagation of the potentials is presented experimentally and through numerical simulations, illustrating prospects for atom guiding without requiring light sheets.

5.
Opt Express ; 27(26): 38359-38366, 2019 Dec 23.
Article in English | MEDLINE | ID: mdl-31878604

ABSTRACT

Clocks based on cold atoms offer unbeatable accuracy and long-term stability, but their use in portable quantum technologies is hampered by a large physical footprint. Here, we use the compact optical layout of a grating magneto-optical trap (gMOT) for a precise frequency reference. The gMOT collects 107 87Rb atoms, which are subsequently cooled to 20 µK in optical molasses. We optically probe the microwave atomic ground-state splitting using lin⊥lin polarised coherent population trapping and a Raman-Ramsey sequence. With ballistic drop distances of only 0.5 mm, the measured short-term fractional frequency stability is 2×10-11/τ.

6.
Article in English | MEDLINE | ID: mdl-31093591

ABSTRACT

The SU(1,1) interferometer was originally conceived as a Mach-Zehnder interferometer with the beam-splitters replaced by parametric amplifiers. The parametric amplifiers produce states with correlations that result in enhanced phase sensitivity. F = 1 spinor Bose-Einstein condensates (BECs) can serve as the parametric amplifiers for an atomic version of such an interferometer by collisionally producing entangled pairs of |F = 1, m = ±1〉 atoms. We simulate the effect of single and double-sided seeding of the inputs to the amplifier using the truncated-Wigner approximation. We find that single-sided seeding degrades the performance of the interferometer exactly at the phase the unseeded interferometer should operate the best. Double-sided seeding results in a phase-sensitive amplifier, where the maximal sensitivity is a function of the phase relationship between the input states of the amplifier. In both single and double-sided seeding we find there exists an optimal phase that achieves sensitivity beyond the standard quantum limit. Experimentally, we demonstrate a spinor phase-sensitive amplifier using a BEC of 23Na in an optical dipole trap. This configuration could be used as an input to such an interferometer. We are able to control the initial phase of the double-seeded amplifier, and demonstrate sensitivity to initial population fractions as small as 0.1%.

7.
Rev Sci Instrum ; 88(4): 043109, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28456251

ABSTRACT

An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 µT within a five-layer Mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S1/2 F = 4 133Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated with one-sigma tolerances in magnitude, orientation, and gradient of δ|B| = 0.94 nT, δθ = 5.9 mrad, and δ|∇B|=13.0 pT/mm, respectively. This field control is used to empirically map Mx magnetometer signal amplitude as a function of the static field (B0) orientation.

8.
Appl Phys B ; 122(6): 172, 2016.
Article in English | MEDLINE | ID: mdl-32355419

ABSTRACT

It has recently been shown that optical reflection gratings fabricated directly into an atom chip provide a simple and effective way to trap and cool substantial clouds of atoms (Nshii et al. in Nat Nanotechnol 8:321-324, 2013; McGilligan et al. in Opt Express 23(7):8948-8959, 2015). In this article, we describe how the gratings are designed and microfabricated and we characterise their optical properties, which determine their effectiveness as a cold atom source. We use simple scalar diffraction theory to understand how the morphology of the gratings determines the power in the diffracted beams.

9.
Opt Express ; 23(7): 8948-59, 2015 Apr 06.
Article in English | MEDLINE | ID: mdl-25968732

ABSTRACT

We have used diffraction gratings to simplify the fabrication, and dramatically increase the atomic collection efficiency, of magneto-optical traps using micro-fabricated optics. The atom number enhancement was mainly due to the increased beam capture volume, afforded by the large area (4cm(2)) shallow etch (~ 200nm) binary grating chips. Here we provide a detailed theoretical and experimental investigation of the on-chip magneto-optical trap temperature and density in four different chip geometries using (87)Rb, whilst studying effects due to MOT radiation pressure imbalance. With optimal initial MOTs on two of the chips we obtain both large atom number (2×10(7)) and sub-Doppler temperatures (50 µK) after optical molasses.

10.
Phys Rev Lett ; 111(2): 025301, 2013 Jul 12.
Article in English | MEDLINE | ID: mdl-23889412

ABSTRACT

We present experimental observations of coherent spin-population oscillations in a cold thermal, Bose gas of spin-1 23Na atoms. The population oscillations in a multi-spatial-mode thermal gas have the same behavior as those observed in a single-spatial-mode antiferromagnetic spinor Bose-Einstein condensate. We demonstrate this by showing that the two situations are described by the same dynamical equations, with a factor of 2 change in the spin-dependent interaction coefficient, which results from the change to particles with distinguishable momentum states in the thermal gas. We compare this theory to the measured spin population evolution after times up to a few hundreds of ms, finding quantitative agreement with the amplitude and period. We also measure the damping time of the oscillations as a function of magnetic field.

11.
Nat Nanotechnol ; 8(5): 321-4, 2013 May.
Article in English | MEDLINE | ID: mdl-23563845

ABSTRACT

Laser-cooled atoms are central to modern precision measurements. They are also increasingly important as an enabling technology for experimental cavity quantum electrodynamics, quantum information processing and matter-wave interferometry. Although significant progress has been made in miniaturizing atomic metrological devices, these are limited in accuracy by their use of hot atomic ensembles and buffer gases. Advances have also been made in producing portable apparatus that benefits from the advantages of atoms in the microkelvin regime. However, simplifying atomic cooling and loading using microfabrication technology has proved difficult. In this Letter we address this problem, realizing an atom chip that enables the integration of laser cooling and trapping into a compact apparatus. Our source delivers ten thousand times more atoms than previous magneto-optical traps with microfabricated optics and, for the first time, can reach sub-Doppler temperatures. Moreover, the same chip design offers a simple way to form stable optical lattices. These features, combined with simplicity of fabrication and ease of operation, make these new traps a key advance in the development of cold-atom technology for high-accuracy, portable measurement devices.

12.
Rev Sci Instrum ; 80(2): 026105, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19256681

ABSTRACT

We present a viewport for use in ultrahigh vacuum (UHV) based upon the preflattened solder seal design presented in earlier work [Cox et al., Rev. Sci. Instrum. 74, 3185 (2003)]. The design features significant modifications to improve long term performance. The windows have been leak tested to less than 10(-10) atm cm(3)/s. From atom number measurements in an optical dipole trap loaded from a vapor cell magneto-optical trap inside a vacuum chamber accommodating these viewports, we measure a trap lifetime of 9.5 s suggesting a pressure of around 10(-10) Torr limited by background rubidium vapor pressure. We also present a simplified design where the UHV seal is made directly to a vacuum pipe.

SELECTION OF CITATIONS
SEARCH DETAIL
...