Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Chem Commun (Camb) ; 60(9): 1188-1191, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38193881

ABSTRACT

A versatile, robust, and stable tetrabutylammonium difluorotriphenylsilicate (TBAT) catalyst has been deployed for efficient depolymerization of silicones. This catalyst is soluble in a variety of organic solvents and is stable up to 170 °C, enabling a wide range of reaction conditions under which F--catalysed siloxane bond cleavage can be initiated. This effort offers significant advancement overcoming the traditional limitations of silicone depolymerization, such as high catalyst loading, storage and handling, and few viable reaction media.

2.
PLoS One ; 16(4): e0248859, 2021.
Article in English | MEDLINE | ID: mdl-33831014

ABSTRACT

In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40-50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.


Subject(s)
COVID-19/prevention & control , Gamma Rays , N95 Respirators/virology , SARS-CoV-2 , Sterilization , Virus Inactivation/radiation effects , COVID-19/transmission , Humans , United States
3.
Exp Biol Med (Maywood) ; 246(6): 740-748, 2021 03.
Article in English | MEDLINE | ID: mdl-33325749

ABSTRACT

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.


Subject(s)
COVID-19/prevention & control , Decontamination/methods , N95 Respirators/supply & distribution , 2-Propanol/pharmacology , Detergents/pharmacology , Humans , Hydrogen Peroxide/pharmacology , SARS-CoV-2 , Sodium Hypochlorite/pharmacology , Static Electricity , Ultraviolet Rays
4.
Lab Chip ; 12(8): 1540-7, 2012 Apr 21.
Article in English | MEDLINE | ID: mdl-22398953

ABSTRACT

A thin flow-focusing microfluidic channel is evaluated for generating monodisperse liquid droplets. The microfluidic device is used in its native state, which is hydrophilic, or treated with OTS to make it hydrophobic. Having both hydrophilic and hydrophobic surfaces allows for creation of both oil-in-water and water-in-oil emulsions, facilitating a large parameter study of viscosity ratios (droplet fluid/continuous fluid) ranging from 0.05 to 96 and flow rate ratios (droplet fluid/continuous fluid) ranging from 0.01 to 2 in one geometry. The hydrophilic chip provides a partially-wetting surface (contact angle less than 90°) for the inner fluid. This surface, combined with the unusually thin channel height, promotes a flow regime where the inner fluid wets the top and bottom of the channel in the orifice and a stable jet is formed. Through confocal microscopy, this fluid stabilization is shown to be highly influenced by the contact angle of the liquids in the channel. Non-wetting jets undergo breakup and produce drops when the jet is comparable to or smaller than the channel thickness. In contrast, partially-wetting jets undergo breakup only when they are much smaller than the channel thickness. Drop sizes are found to scale with a modified capillary number based on the total flow rate regardless of wetting behavior.

5.
Biotechnol Bioeng ; 109(2): 493-501, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21882173

ABSTRACT

The effects of algae concentration, ferric chloride dose, and pH on the flocculation efficiency of the freshwater algae Chlorella zofingiensis can be understood by considering the nature of the electrostatic charges on the algae and precipitate surfaces. Two critical conditions are identified which, when met, result in flocculation efficiencies in excess of 90% for freshwater algae. First, a minimum concentration of ferric chloride is required to overcome the electrostatic stabilization of the algae and promote bridging of algae cells by hydroxide precipitates. At low algae concentrations, the minimum amount of ferric chloride required increases linearly with algae concentration, characteristic of flocculation primarily through electrostatic bridging by hydroxide precipitates. At higher algae concentrations, the minimum required concentration of ferric chloride for flocculation is independent of algae concentration, suggesting a change in the primary flocculation mechanism from bridging to sweep flocculation. Second, the algae must have a negative surface charge. Experiments and surface complexation modeling show that the surface charge of C. zofingiensis is negative above a pH of 4.0 ± 0.3 which agrees well with the minimum pH required for effective flocculation. These critical flocculation criteria can be extended to other freshwater algae to design effective flocculation systems.


Subject(s)
Chlorella/physiology , Chlorides/chemistry , Ferric Compounds/chemistry , Biomass , Chlorella/chemistry , Flocculation , Fresh Water , Hydrogen-Ion Concentration , Models, Biological , Particle Size , Static Electricity
6.
J Colloid Interface Sci ; 317(1): 264-74, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-17945243

ABSTRACT

A method to measure interfacial mechanical properties at high temperatures and in a controlled atmosphere has been developed to study anodized aluminum surface coatings at temperatures where the interior aluminum alloy is molten. This is the first time that the coating strength has been studied under these conditions. We have investigated the effects of ambient atmosphere, temperature, and surface finish on coating strength for samples of aluminum alloy 7075. Surprisingly, the effective Young's modulus or strength of the coating when tested in air was twice as high as when samples were tested in an inert nitrogen or argon atmosphere. Additionally, the effective Young's modulus of the anodized coating increased with temperature in an air atmosphere but was independent of temperature in an inert atmosphere. The effect of surface finish was also examined. Sandblasting the surface prior to anodization was found to increase the strength of the anodized coating with the greatest enhancement noted for a nitrogen atmosphere. Machining marks were not found to significantly affect the strength.

7.
Rev Sci Instrum ; 78(9): 093902, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17902957

ABSTRACT

We have developed a novel flow chamber which imposes a controlled axisymmetric stagnation flow to enable the study of external flow effects on coalescence dynamics. This system allows for the first time the precise positioning of a drop in a three dimensional flow and additionally enforces a highly symmetric flow around the drop. We focus on the study of a single drop approaching a stationary flat plane as this is analogous to two drops approaching each other. A single drop is created and then guided along the unsteady center line of a stagnation flow. The real time computer control algorithm analyzes video images of the drop in two orthogonal planes and manipulates flow restricting valves along the four outlets of the flow. We demonstrate using particle image velocimetry that the computer control not only controls the drop position but also ensures a symmetric flow inside the flow chamber. This chamber will enable a detailed investigation of the drainage of the thin film between the drop and the lower surface in order to probe the effect of external flow on coalescence.

8.
Langmuir ; 22(24): 9928-41, 2006 Nov 21.
Article in English | MEDLINE | ID: mdl-17106982

ABSTRACT

The dynamics of polymeric liquids and mixtures spreading on a solid surface have been investigated on completely wetting and partially wetting surfaces. Drops were formed by pushing the test liquid through a hole in the underside of the substrate, and the drop profiles were monitored as the liquid wet the surface. Silicon surfaces coated with diphenyldichlorosilane (DPDCS) and octadecyltrichlorosilane (OTS) were used as wetting and partial wetting surfaces, respectively, for the fluids we investigated. The response under complete and partial wetting conditions for a series of polypropylene glycols (PPG) with different molecular weights and the same surface tension could be collapsed onto a single curve when scaling time based on the fluid viscosity, the liquid-vapor surface tension, and the radius of a spherical drop with equivalent volume. A poly(ethylene glycol) (PEG300) and a series of poly(ethylene oxide-rand-propylene oxide) copolymers did not show the same viscosity scaling when spread on the partially wetting surface. A combined model incorporating hydrodynamic and molecular-kinetic wetting models adequately described the complete wetting results. The assumptions in the hydrodynamic model, however, were not valid under the partial wetting conditions in our work, and the molecular-kinetic model was chosen to describe our results. The friction coefficient used in the molecular-kinetic model exhibited a nonlinear dependence with viscosity for the copolymers, indicating a more complex relationship between the friction coefficient and the fluid viscosity.

SELECTION OF CITATIONS
SEARCH DETAIL
...