Results 1 - 20 de 193
Filter
1.
ArXiv ; 2024 May 01.
Article in English | MEDLINE | ID: mdl-38745701

ABSTRACT

Quantitative MRI enables direct quantification of contrast agent concentrations in contrast-enhanced scans. However, the lengthy scan times required by conventional methods are inadequate for tracking contrast agent transport dynamically in mouse brain. We developed a 3D MR fingerprinting (MRF) method for simultaneous T1 and T2 mapping across the whole mouse brain with 4.3-min temporal resolution. We designed a 3D MRF sequence with variable acquisition segment lengths and magnetization preparations on a 9.4T preclinical MRI scanner. Model-based reconstruction approaches were employed to improve the accuracy and speed of MRF acquisition. The method's accuracy for T1 and T2 measurements was validated in vitro, while its repeatability of T1 and T2 measurements was evaluated in vivo (n=3). The utility of the 3D MRF sequence for dynamic tracking of intracisternally infused Gd-DTPA in the whole mouse brain was demonstrated (n=5). Phantom studies confirmed accurate T1 and T2 measurements by 3D MRF with an undersampling factor up to 48. Dynamic contrast-enhanced (DCE) MRF scans achieved a spatial resolution of 192 x 192 x 500 um3 and a temporal resolution of 4.3 min, allowing for the analysis and comparison of dynamic changes in concentration and transport kinetics of intracisternally infused Gd-DTPA across brain regions. The sequence also enabled highly repeatable, high-resolution T1 and T2 mapping of the whole mouse brain (192 x 192 x 250 um3) in 30 min. We present the first dynamic and multi-parametric approach for quantitatively tracking contrast agent transport in the mouse brain using 3D MRF.

2.
Magn Reson Med ; 91(5): 2074-2088, 2024 May.
Article in English | MEDLINE | ID: mdl-38192239

ABSTRACT

PURPOSE: Quantitative MRI techniques such as MR fingerprinting (MRF) promise more objective and comparable measurements of tissue properties at the point-of-care than weighted imaging. However, few direct cross-modal comparisons of MRF's repeatability and reproducibility versus weighted acquisitions have been performed. This work proposes a novel fully automated pipeline for quantitatively comparing cross-modal imaging performance in vivo via atlas-based sampling. METHODS: We acquire whole-brain 3D-MRF, turbo spin echo, and MPRAGE sequences three times each on two scanners across 10 subjects, for a total of 60 multimodal datasets. The proposed automated registration and analysis pipeline uses linear and nonlinear registration to align all qualitative and quantitative DICOM stacks to Montreal Neurological Institute (MNI) 152 space, then samples each dataset's native space through transformation inversion to compare performance within atlas regions across subjects, scanners, and repetitions. RESULTS: Voxel values within MRF-derived maps were found to be more repeatable (σT1 = 1.90, σT2 = 3.20) across sessions than vendor-reconstructed MPRAGE (σT1w = 6.04) or turbo spin echo (σT2w = 5.66) images. Additionally, MRF was found to be more reproducible across scanners (σT1 = 2.21, σT2 = 3.89) than either qualitative modality (σT1w = 7.84, σT2w = 7.76). Notably, differences between repeatability and reproducibility of in vivo MRF were insignificant, unlike the weighted images. CONCLUSION: MRF data from many sessions and scanners can potentially be treated as a single dataset for harmonized analysis or longitudinal comparisons without the additional regularization steps needed for qualitative modalities.


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Phantoms, Imaging , Image Processing, Computer-Assisted/methods
3.
Magn Reson Med ; 91(5): 1978-1993, 2024 May.
Article in English | MEDLINE | ID: mdl-38102776

ABSTRACT

PURPOSE: To propose a new reconstruction method for multidimensional MR fingerprinting (mdMRF) to address shading artifacts caused by physiological motion-induced measurement errors without navigating or gating. METHODS: The proposed method comprises two procedures: self-calibration and subspace reconstruction. The first procedure (self-calibration) applies temporally local matrix completion to reconstruct low-resolution images from a subset of under-sampled data extracted from the k-space center. The second procedure (subspace reconstruction) utilizes temporally global subspace reconstruction with pre-estimated temporal subspace from low-resolution images to reconstruct aliasing-free, high-resolution, and time-resolved images. After reconstruction, a customized outlier detection algorithm was employed to automatically detect and remove images corrupted by measurement errors. Feasibility, robustness, and scan efficiency were evaluated through in vivo human brain imaging experiments. RESULTS: The proposed method successfully reconstructed aliasing-free, high-resolution, and time-resolved images, where the measurement errors were accurately represented. The corrupted images were automatically and robustly detected and removed. Artifact-free T1, T2, and ADC maps were generated simultaneously. The proposed reconstruction method demonstrated robustness across different scanners, parameter settings, and subjects. A high scan efficiency of less than 20 s per slice has been achieved. CONCLUSION: The proposed reconstruction method can effectively alleviate shading artifacts caused by physiological motion-induced measurement errors. It enables simultaneous and artifact-free quantification of T1, T2, and ADC using mdMRF scans without prospective gating, with robustness and high scan efficiency.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Algorithms , Phantoms, Imaging , Artifacts
4.
Brain Stimul ; 16(6): 1799-1805, 2023.
Article in English | MEDLINE | ID: mdl-38135359

ABSTRACT

BACKGROUND: Connectomic modeling studies are expanding understanding of the brain networks that are modulated by deep brain stimulation (DBS) therapies. However, explicit integration of these modeling results into prospective neurosurgical planning is only beginning to evolve. One challenge of employing connectomic models in patient-specific surgical planning is the inherent 3D nature of the results, which can make clinically useful data integration and visualization difficult. METHODS: We developed a holographic stereotactic neurosurgery research tool (HoloSNS) that integrates patient-specific brain models into a group-based visualization environment for interactive surgical planning using connectomic hypotheses. HoloSNS currently runs on the HoloLens 2 platform and it enables remote networking between headsets. This allowed us to perform surgical planning group meetings with study co-investigators distributed across the country. RESULTS: We used HoloSNS to plan stereo-EEG and DBS electrode placements for each patient participating in a clinical trial (NCT03437928) that is targeting both the subcallosal cingulate and ventral capsule for the treatment of depression. Each patient model consisted of multiple components of scientific data and anatomical reconstructions of the head and brain (both patient-specific and atlas-based), which far exceed the data integration capabilities of traditional neurosurgical planning workstations. This allowed us to prospectively discuss and evaluate the positioning of the electrodes based on novel connectomic hypotheses. CONCLUSIONS: The 3D nature of the surgical procedure, brain imaging data, and connectomic modeling results all highlighted the utility of employing holographic visualization to support the design of unique clinical experiments to explore brain network modulation with DBS.


Subject(s)
Deep Brain Stimulation , Mental Disorders , Humans , Prospective Studies , Deep Brain Stimulation/methods , Brain/diagnostic imaging , Mental Disorders/therapy , Electroencephalography
5.
Mult Scler Relat Disord ; 79: 105024, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37783196

ABSTRACT

BACKGROUND: In this cross sectional study, we used MRF to investigate tissue properties of normal-appearing white matter, gray matter, and lesions in relapsing remitting MS (n = 21), secondary progressive MS (n = 16) and healthy controls (n = 9). A FISP-based MRF sequence was used for acquisition, imaging time 5 min 15 s. MRF T1 and T2 relaxation times were measured from lesional tissue, normal-appearing frontal white matter, corpus callous, thalamus, and caudate. Differences between healthy controls and MS were examined using ANCOVA adjusted for age and sex. Spearman rank correlations were assessed between T1 and T2 relaxation times and clinical measures. OBJECTIVES: To examine brain T1 and T2 values using magnetic resonance fingerprinting (MRF) in healthy controls and MS. METHODS: The subjects included 21 relapsing-remitting (RR) MS, 16 secondary progressive (SP) MS, and 9 age- and sex-matched HC without manifest neurological disease participating in a longitudinal MRI study. A 3T/ FISP-based MRF sequence was acquired. Regions of interest were drawn for lesions and normal appearing white matter. ANCOVA adjusted for age and sex were used to compare the groups with significance set at 0.05. RESULTS: A step-wise increase in T1 and T2 relaxation times was found between healthy controls, relapsing remitting MS, and secondary progressive MS. Significant differences were found in T1 and T2 between MS and healthy controls in the frontal normal-appearing white matter, corpus callosum, and thalamus (p < 0.04 for all). Significant differences in T1 and T2 between RR and SPMS were found in the frontal normal-appearing white matter and T2 lesions (p < 0.02 for all). T1 relaxation from the frontal normal-appearing white matter correlated with the Expanded Disability Status Scale [ρ = 0.62, p < 0.001], timed 25 foot walk (ρ = 0.45, p = 0.01), 9 hole peg test (ρ = 0.62, p < 0.001), and paced auditory serial addition test (ρ = -0.4, p = 0.01). CONCLUSION: These results suggest that MRF may be a clinically feasible quantitative approach for characterizing tissue damage in MS.


Subject(s)
Multiple Sclerosis, Relapsing-Remitting , Multiple Sclerosis , Humans , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology , Cross-Sectional Studies , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Brain/diagnostic imaging , Brain/pathology , Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/pathology
6.
Magn Reson Med ; 90(5): 1802-1817, 2023 11.
Article in English | MEDLINE | ID: mdl-37345703

ABSTRACT

PURPOSE: To develop a 3D MR fingerprinting (MRF) method in combination with fat navigators to improve its motion robustness for neuroimaging. METHODS: A rapid fat navigator was developed using the stack-of-spirals acquisition and non-Cartesian spiral GRAPPA. The fat navigator module was implemented in the 3D MRF sequence with high scan efficiency. The developed method was first validated in phantoms and five healthy subjects with intentional head motion. The method was further applied to infants with neonatal opioid withdrawal symptoms. The 3D MRF scans with fat navigators acquired with and without acceleration along the partition-encoding direction were both examined in the study. RESULTS: Both phantom and in vivo results demonstrated that the added fat navigator modules did not influence the quantification accuracy in MRF. In combination with non-Cartesian spiral GRAPPA, a rapid fat navigator sampling with whole-brain coverage was achieved in ˜0.5 s at 3T, reducing its sensitivity to potential motion. Based on the motion waveforms extracted from fat navigators, the motion robustness of the 3D MRF was largely improved. With the proposed method, the motion-corrupted MRF datasets yielded T1 and T2 maps with significantly reduced artifacts and high correlations with measurements from the reference motion-free MRF scans. CONCLUSION: We developed a 3D MRF method coupled with rapid fat navigators to improve its motion robustness for quantitative neuroimaging. Our results demonstrate that (1) accurate tissue quantification was preserved with the fat navigator modules and (2) the motion robustness for quantitative tissue mapping was largely improved with the developed method.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Infant, Newborn , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Motion , Phantoms, Imaging
7.
Eur J Radiol ; 164: 110883, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37209463

ABSTRACT

PURPOSE: To quantify and assess the distribution of MR fingerprinting (MRF)-derived T1 and T2 values of the whole prostatic peripheral zone (PZ), and perform subgroup analyses according to clinical and demographic features. METHOD: One hundred and twenty-four patients with prostate MR exams and MRF-based T1 and T2 maps of the prostatic apex, mid gland, and base were identified from our database and included. Regions of interest encompassing the right and left lobes of the PZ were drawn for each axial slice on the T2 map and copied to the T1 map. Clinical data were obtained from medical records. Kruskal-Wallis test was used for assessing differences between subgroups and the Spearman coefficient was used for assessing any correlations. RESULTS: Mean T1 and T2 values were 1941 and 88 ms, respectively, for the whole-gland, 1884 and 83 ms for the apex, 1974 and 92 ms for the mid-gland, 1966 and 88 ms for the base. T1 values were weakly negatively correlated with PSA values, while T1 and T2 values were weakly positively correlated with prostate weight and moderately positively correlated with PZ width. Finally, patients with PI-RADS 1 scores had higher T1 and T2 values of the whole PZ, compared with those with scores 2-5. CONCLUSION: Mean T1 and T2 values of the background PZ of the whole gland were 1941 ± 313 and 88 ± 39 ms, respectively. Among clinical and demographic factors, there was a significant positive correlation between T1 and T2 values and PZ width.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Male , Humans , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostate/diagnostic imaging , Prostate/pathology , Magnetic Resonance Spectroscopy , Demography
9.
Magn Reson Imaging ; 98: 105-114, 2023 05.
Article in English | MEDLINE | ID: mdl-36681312

ABSTRACT

Magnetic resonance fingerprinting (MRF) is a novel quantitative MR technique that simultaneously provides multiple tissue property maps. When optimizing MRF scans, modeling undersampling errors and field imperfections in cost functions for direct measurement of quantitative errors will make the optimization results more practical and robust. However, optimizing such cost function is computationally expensive and impractical for MRF optimization with tens of thousands of iterations. Here, we introduce a fast MRF simulator to simulate aliased images from actual scan scenarios including undersampling and system imperfections, which substantially reduces computational time and allows for direct error estimation of the quantitative maps and efficient sequence optimization. We evaluate the performance and computational speed of the proposed approach by simulations and in vivo experiments. The simulations from the proposed method closely approximate the signals and MRF maps from in vivo scans, with 158 times shorter processing time than the conventional simulation method using Non-uniform Fourier transform. We also demonstrate the power of applying the fast MRF simulator in MRF sequence optimization. The optimized sequences are validated with in vivo scans to assess the image quality and accuracy. The optimized sequences produce artifact-free T1 and T2 maps in 2D and 3D scans with equivalent mapping accuracy as the human-designed sequence but at shorter scan times. Incorporating the proposed simulator in the MRF optimization framework makes direct estimation of undersampling errors during the optimization process feasible, and provide optimized MRF sequences that are robust against undersampling artifacts and field inhomogeneity.


Subject(s)
Brain , Image Processing, Computer-Assisted , Humans , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Algorithms
10.
Eur Radiol ; 33(2): 836-844, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35999374

ABSTRACT

OBJECTIVES: To test the feasibility of using 3D MRF maps with radiomics analysis and machine learning in the characterization of adult brain intra-axial neoplasms. METHODS: 3D MRF acquisition was performed on 78 patients with newly diagnosed brain tumors including 33 glioblastomas (grade IV), 6 grade III gliomas, 12 grade II gliomas, and 27 patients with brain metastases. Regions of enhancing tumor, non-enhancing tumor, and peritumoral edema were segmented and radiomics analysis with gray-level co-occurrence matrices and gray-level run-length matrices was performed. Statistical analysis was performed to identify features capable of differentiating tumors based on type, grade, and isocitrate dehydrogenase (IDH1) status. Receiver operating curve analysis was performed and the area under the curve (AUC) was calculated for tumor classification and grading. For gliomas, Kaplan-Meier analysis for overall survival was performed using MRF T1 features from enhancing tumor region. RESULTS: Multiple MRF T1 and T2 features from enhancing tumor region were capable of differentiating glioblastomas from brain metastases. Although no differences were identified between grade 2 and grade 3 gliomas, differentiation between grade 2 and grade 4 gliomas as well as between grade 3 and grade 4 gliomas was achieved. MRF radiomics features were also able to differentiate IDH1 mutant from the wild-type gliomas. Radiomics T1 features for enhancing tumor region in gliomas correlated to overall survival (p < 0.05). CONCLUSION: Radiomics analysis of 3D MRF maps allows differentiating glioblastomas from metastases and is capable of differentiating glioblastomas from metastases and characterizing gliomas based on grade, IDH1 status, and survival. KEY POINTS: • 3D MRF data analysis using radiomics offers novel tissue characterization of brain tumors. • 3D MRF with radiomics offers glioma characterization based on grade, IDH1 status, and overall patient survival.


Subject(s)
Brain Neoplasms , Glioblastoma , Glioma , Adult , Humans , Feasibility Studies , Magnetic Resonance Imaging , Brain Neoplasms/pathology , Glioma/pathology , Magnetic Resonance Spectroscopy , Isocitrate Dehydrogenase/genetics , Mutation , Neoplasm Grading
11.
Cereb Cortex ; 33(7): 3562-3574, 2023 03 21.
Article in English | MEDLINE | ID: mdl-35945683

ABSTRACT

Quantitative magnetic resonance (MR) has been used to study cyto- and myelo-architecture of the human brain non-invasively. However, analyzing brain cortex using high-resolution quantitative MR acquisition can be challenging to perform using 3T clinical scanners. MR fingerprinting (MRF) is a highly efficient and clinically feasible quantitative MR technique that simultaneously provides T1 and T2 relaxation maps. Using 3D MRF from 40 healthy subjects (mean age = 25.6 ± 4.3 years) scanned on 3T magnetic resonance imaging, we generated whole-brain gyral-based normative MR relaxation atlases and investigated cortical-region-based T1 and T2 variations. Gender and age dependency of T1 and T2 variations were additionally analyzed. The coefficient of variation of T1 and T2 for each cortical-region was 3.5% and 7.3%, respectively, supporting low variability of MRF measurements across subjects. Significant differences in T1 and T2 were identified among 34 brain regions (P < 0.001), lower in the precentral, postcentral, paracentral lobule, transverse temporal, lateral occipital, and cingulate areas, which contain sensorimotor, auditory, visual, and limbic functions. Significant correlations were identified between age and T1 and T2 values. This study established whole-brain MRF T1 and T2 atlases of healthy subjects using a clinical 3T scanner, which can provide a quantitative and region-specific baseline for future brain studies and pathology detection.


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Young Adult , Adult , Infant , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Phantoms, Imaging , Healthy Volunteers , Image Processing, Computer-Assisted/methods
12.
Epilepsia ; 63(8): 1998-2010, 2022 08.
Article in English | MEDLINE | ID: mdl-35661353

ABSTRACT

OBJECTIVES: Magnetic resonance fingerprinting (MRF) is a novel, quantitative, and noninvasive technique to measure brain tissue properties. We aim to use MRF for characterizing normal-appearing thalamic and basal ganglia nuclei in the epileptic brain. METHODS: A three-dimensional (3D) MRF protocol (1 mm3 isotropic resolution) was acquired from 48 patients with unilateral medically intractable focal epilepsy and 39 healthy controls (HCs). Whole-brain T1 and T2 maps (containing T1 and T2 relaxation times) were reconstructed for each subject. Ten subcortical nuclei in the thalamus and basal ganglia were segmented as regions of interest (ROIs), within which the mean T1 and T2 values, as well as their coefficient of variation (CV) were compared between the patients and HCs at the group level. Subgroup and correlation analyses were performed to examine the relationship between significant MRF measures and various clinical characteristics. Using significantly abnormal MRF measures from the group-level analyses, support vector machine (SVM) and logistic regression machine learning models were built and tested with 5-fold and 10-fold cross-validations, to separate patients from HCs, and to separate patients with left-sided and right-sided epilepsy, at the individual level. RESULTS: MRF revealed increased T1 mean value in the ipsilateral thalamus and nucleus accumbens; increased T1 CV in the bilateral thalamus, bilateral pallidum, and ipsilateral caudate; and increased T2 CV in the ipsilateral thalamus in patients compared to HCs (p < .05, false discovery rate [FDR] corrected). The SVM classifier produced 78.2% average accuracy to separate individual patients from HCs, with an area under the curve (AUC) of 0.83. The logistic regression classifier produced 67.4% average accuracy to separate patients with left-sided and right-sided epilepsy, with an AUC of 0.72. SIGNIFICANCE: MRF revealed bilateral tissue-property changes in the normal-appearing thalamus and basal ganglia, with ipsilateral predominance and thalamic preference, suggesting subcortical involvement/impairment in patients with medically intractable focal epilepsy. The individual-level performance of the MRF-based machine-learning models suggests potential opportunities for predicting lateralization.


Subject(s)
Drug Resistant Epilepsy , Epilepsies, Partial , Epilepsy , Basal Ganglia/diagnostic imaging , Drug Resistant Epilepsy/diagnostic imaging , Epilepsies, Partial/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Thalamus/diagnostic imaging
13.
Magn Reson Med ; 88(5): 2043-2057, 2022 11.
Article in English | MEDLINE | ID: mdl-35713357

ABSTRACT

PURPOSE: Although both relaxation and diffusion imaging are sensitive to tissue microstructure, studies have reported limited sensitivity and robustness of using relaxation or conventional diffusion alone to characterize tissue microstructure. Recently, it has been shown that tensor-valued diffusion encoding and joint relaxation-diffusion quantification enable more reliable quantification of compartment-specific microstructural properties. However, scan times to acquire such data can be prohibitive. Here, we aim to simultaneously quantify relaxation and diffusion using MR fingerprinting (MRF) and b-tensor encoding in a clinically feasible time. METHODS: We developed multidimensional MRF scans (mdMRF) with linear and spherical b-tensor encoding (LTE and STE) to simultaneously quantify T1, T2, and ADC maps from a single scan. The image quality, accuracy, and scan efficiency were compared between the mdMRF using LTE and STE. Moreover, we investigated the robustness of different sequence designs to signal errors and their impact on the maps. RESULTS: T1 and T2 maps derived from the mdMRF scans have consistently high image quality, while ADC maps are sensitive to different sequence designs. Notably, the fast imaging steady state precession (FISP)-based mdMRF scan with peripheral pulse gating provides the best ADC maps that are free of image distortion and shading artifacts. CONCLUSION: We demonstrated the feasibility of quantifying T1, T2, and ADC maps simultaneously from a single mdMRF scan in around 24 s/slice. The map quality and quantitative values are consistent with the reference scans.


Subject(s)
Brain , Magnetic Resonance Imaging , Brain/diagnostic imaging , Diffusion , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Radionuclide Imaging
14.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Article in English | MEDLINE | ID: mdl-35713379

ABSTRACT

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Subject(s)
Magnetic Resonance Imaging , Prostate , Brazil , Female , Humans , Image Processing, Computer-Assisted , Male , Phantoms, Imaging , Prostate/diagnostic imaging , Reproducibility of Results
15.
Int J Med Educ ; 13: 107-114, 2022 Apr 29.
Article in English | MEDLINE | ID: mdl-35506483

ABSTRACT

Objectives: To evaluate student impressions of learning anatomy with mixed-reality and compare long-term information retention of female breast anatomy between students who learned with a mixed-reality supplement and their classmates who dissected cadavers. Methods: In Part 1, 38 first-year medical student volunteers, randomly divided into two groups, completed a mixed-reality module and cadaveric dissection on the female breast in a counterbalanced design. Participants also completed post-quizzes and surveys. Part 2 was a non-randomized controlled trial, 8-months after completing Part 1 and 6-months after a final exam on this content. The performance of twenty-two Part 1 participants and 129 of their classmates, who only dissected, was compared on a delayed post-quiz. Wilcoxon signed-rank test, Mann-Whitney U test, and 95% confidence intervals were used to analyze the data. Results: In Part 1, the Wilcoxon signed-rank test determined that participants expressed significantly more positive responses to mixed-reality and found mixed-reality easier for learning and teamwork. In Part 2, the Mann-Whitney U test found mixed-reality participants scored significantly higher on a delayed-post quiz than their classmates who only dissected (U = 928, p < .009). Conclusions:   This study suggests that medical students may prefer mixed-reality and that it may be an effective modality for learning breast anatomy while facilitating teamwork. Results also suggest that supplementing cadaveric dissection with mixed-reality may improve long-term retention for at least one anatomical topic. It is recommended that similar studies evaluate a larger sample and additional anatomical regions to determine the generalizability of these findings.


Subject(s)
Students, Medical , Cadaver , Curriculum , Educational Measurement/methods , Female , Humans , Learning
16.
Magn Reson Med ; 88(3): 1081-1097, 2022 09.
Article in English | MEDLINE | ID: mdl-35468232

ABSTRACT

PURPOSE: To perform B1+$$ {B}_1^{+} $$ -selective excitation using the Bloch-Siegert shift for spatial localization. THEORY AND METHODS: A B1+$$ {B}_1^{+} $$ -selective excitation is produced by an radiofrequency (RF) pulse consisting of two summed component pulses: an off-resonant pulse that induces a B1+$$ {B}_1^{+} $$ -dependent Bloch-Siegert frequency shift and a frequency-selective excitation pulse. The passband of the pulse can be tailored by adjusting the frequency content of the frequency-selective pulse, as in conventional B0$$ {B}_0 $$ gradient-localized excitation. Fine magnetization profile control is achieved by using the Shinnar-Le Roux algorithm to design the frequency-selective excitation pulse. Simulations analyzed the pulses' robustness to off-resonance, their suitability for multi-echo spin echo pulse sequences, and how their performance compares to that of rotating-frame selective excitation pulses. The pulses were evaluated experimentally on a 47.5 mT MRI scanner using an RF gradient transmit coil. Multiphoton resonances produced by the pulses were characterized and their distribution across B1+$$ {B}_1^{+} $$ predicted. RESULTS: With correction for varying B1+$$ {B}_1^{+} $$ across the desired profile, the proposed pulses produced selective excitation with the specified profile characteristics. The pulses were robust against off-resonance and RF amplifier distortion, and suitable for multi-echo pulse sequences. Experimental profiles closely matched simulated patterns. CONCLUSION: The Bloch-Siegert shift can be used to perform B0$$ {B}_0 $$ -gradient-free selective excitation, enabling the excitation of slices or slabs in RF gradient-encoded MRI.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Algorithms , Amplifiers, Electronic , Phantoms, Imaging
17.
IEEE Access ; 10: 99205-99220, 2022.
Article in English | MEDLINE | ID: mdl-37041984

ABSTRACT

Magnetic resonance imaging (MRI) guided robotic procedures require safe robotic instrument navigation and precise target localization. This depends on reliable tracking of the instrument from MR images, which requires accurate registration of the robot to the scanner. A novel differential image based robot-to-MRI scanner registration approach is proposed that utilizes a set of active fiducial coils, where background subtraction method is employed for coil detection. In order to use the presented preoperative registration approach jointly with the real-time high speed MRI image acquisition and reconstruction methods in real-time interventional procedures, the effects of the geometric MRI distortion in robot to scanner registration is analyzed using a custom distortion mapping algorithm. The proposed approach is validated by a set of target coils placed within the workspace, employing multi-planar capabilities of the scanner. Registration and validation errors are respectively 2.05 mm and 2.63 mm after the distortion correction showing an improvement of respectively 1.08 mm and 0.14 mm compared to the results without distortion correction.

18.
J Imaging ; 7(12)2021 Dec 14.
Article in English | MEDLINE | ID: mdl-34940741

ABSTRACT

Image-guided cardiovascular interventions are rapidly evolving procedures that necessitate imaging systems capable of rapid data acquisition and low-latency image reconstruction and visualization. Compared to alternative modalities, Magnetic Resonance Imaging (MRI) is attractive for guidance in complex interventional settings thanks to excellent soft tissue contrast and large fields-of-view without exposure to ionizing radiation. However, most clinically deployed MRI sequences and visualization pipelines exhibit poor latency characteristics, and spatial integration of complex anatomy and device orientation can be challenging on conventional 2D displays. This work demonstrates a proof-of-concept system linking real-time cardiac MR image acquisition, online low-latency reconstruction, and a stereoscopic display to support further development in real-time MR-guided intervention. Data are acquired using an undersampled, radial trajectory and reconstructed via parallelized through-time radial generalized autocalibrating partially parallel acquisition (GRAPPA) implemented on graphics processing units. Images are rendered for display in a stereoscopic mixed-reality head-mounted display. The system is successfully tested by imaging standard cardiac views in healthy volunteers. Datasets comprised of one slice (46 ms), two slices (92 ms), and three slices (138 ms) are collected, with the acquisition time of each listed in parentheses. Images are displayed with latencies of 42 ms/frame or less for all three conditions. Volumetric data are acquired at one volume per heartbeat with acquisition times of 467 ms and 588 ms when 8 and 12 partitions are acquired, respectively. Volumes are displayed with a latency of 286 ms or less. The faster-than-acquisition latencies for both planar and volumetric display enable real-time 3D visualization of the heart.

19.
Proc Natl Acad Sci U S A ; 118(40)2021 10 05.
Article in English | MEDLINE | ID: mdl-34593630

ABSTRACT

Magnetic resonance fingerprinting (MRF) is a method to extract quantitative tissue properties such as [Formula: see text] and [Formula: see text] relaxation rates from arbitrary pulse sequences using conventional MRI hardware. MRF pulse sequences have thousands of tunable parameters, which can be chosen to maximize precision and minimize scan time. Here, we perform de novo automated design of MRF pulse sequences by applying physics-inspired optimization heuristics. Our experimental data suggest that systematic errors dominate over random errors in MRF scans under clinically relevant conditions of high undersampling. Thus, in contrast to prior optimization efforts, which focused on statistical error models, we use a cost function based on explicit first-principles simulation of systematic errors arising from Fourier undersampling and phase variation. The resulting pulse sequences display features qualitatively different from previously used MRF pulse sequences and achieve fourfold shorter scan time than prior human-designed sequences of equivalent precision in [Formula: see text] and [Formula: see text] Furthermore, the optimization algorithm has discovered the existence of MRF pulse sequences with intrinsic robustness against shading artifacts due to phase variation.


Subject(s)
Magnetic Resonance Imaging/methods , Algorithms , Automation , Brain/diagnostic imaging , Computer Simulation , Epilepsy/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Neoplasms/diagnostic imaging , Phantoms, Imaging
20.
Magn Reson Imaging ; 81: 88-93, 2021 09.
Article in English | MEDLINE | ID: mdl-34116134

ABSTRACT

BACKGROUND: MR fingerprinting (MRF) is a versatile method for rapid multi-parametric quantification. The application of MRF for lower MRI field could enable multi-contrast imaging and improve exam efficiency on these systems. The purpose of this work is to demonstrate the feasibility of 3D whole-brain T1 and T2 mapping using MR fingerprinting on a contemporary 0.55 T MRI system. MATERIALS AND METHODS: A 3D whole brain stack-of-spirals FISP MRF sequence was implemented for 0.55 T. Quantification was validated using the NIST/ISMRM Quantitative MRI phantom, and T1 and T2 values of white matter, gray matter, and cerebrospinal fluid were measured in 19 healthy subjects. To assess MRF performance in the lower SNR regime of 0.55 T, measurement precision was calculated from 100 simulated pseudo-replicas of in vivo data and within-session measurement repeatability was evaluated. RESULTS: T1 and T2 values calculated by MRF were strongly correlated to standard measurements in the ISMRM/NIST MRI system phantom (R2 > 0.99), with a small constant bias of approximately 5 ms in T2 values. 3D stack-of-spirals MRF was successfully applied for whole brain quantitative T1 and T2 at 0.55 T, with spatial resolution of 1.2 mm × 1.2 mm × 5 mm, and acquisition time of 8.5 min. Moreover, the T1 and T2 quantifications had precision <5%, despite the lower SNR of 0.55 T. CONCLUSION: A 3D whole-brain stack-of-spirals FISP MRF sequence is feasible for T1 and T2 mapping at 0.55 T.


Subject(s)
Brain , Magnetic Resonance Imaging , Brain/diagnostic imaging , Feasibility Studies , Healthy Volunteers , Humans , Phantoms, Imaging