Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J Anesth Analg Crit Care ; 2(1): 4, 2022 Jan 24.
Article in English | MEDLINE | ID: mdl-37386589

ABSTRACT

The inodilator levosimendan, in clinical use for over two decades, has been the subject of extensive clinical and experimental evaluation in various clinical settings beyond its principal indication in the management of acutely decompensated chronic heart failure. Critical care and emergency medicine applications for levosimendan have included postoperative settings, septic shock, and cardiogenic shock. As the experience in these areas continues to expand, an international task force of experts from 15 countries (Austria, Belgium, China, Croatia, Finland, France, Germany, Greece, Hungary, Italy, the Netherlands, Spain, Sweden, Switzerland, and the USA) reviewed and appraised the latest additions to the database of levosimendan use in critical care, considering all the clinical studies, meta-analyses, and guidelines published from September 2019 to November 2021. Overall, the authors of this opinion paper give levosimendan a "should be considered" recommendation in critical care and emergency medicine settings, with different levels of evidence in postoperative settings, septic shock, weaning from mechanical ventilation, weaning from veno-arterial extracorporeal membrane oxygenation, cardiogenic shock, and Takotsubo syndrome, in all cases when an inodilator is needed to restore acute severely reduced left or right ventricular ejection fraction and overall haemodynamic balance, and also in the presence of renal dysfunction/failure.

2.
Anaesthesist ; 70(9): 772-784, 2021 09.
Article in German | MEDLINE | ID: mdl-33660043

ABSTRACT

BACKGROUND: The number of high-risk patients undergoing surgery is steadily increasing. In order to maintain and, if necessary, optimize perioperative hemodynamics as well as the oxygen supply to the organs (DO2) in this patient population, a timely assessment of cardiac function and the underlying pathophysiological causes of hemodynamic instability is essential for the anesthesiologist. A variety of hemodynamic monitoring procedures are available for this purpose; however, due to method-immanent limitations they are often not able to directly identify the underlying cause of cardiovascular impairment. OBJECTIVE: To present a stepwise algorithm for a perioperative echocardiography-based hemodynamic optimization in noncardiac surgery high-risk patients. In this context, echocardiography on demand according to international guidelines can be performed under certain conditions (hemodynamic instability, nonresponse to hemodynamic treatment) as well as in the context of a planned intraoperative procedure, mostly as a transesophageal echocardiography. METHODS AND RESULTS: Hemodynamically focused echocardiography as a rapidly available bedside method, enables the timely diagnosis and assessment of cardiac filling obstructions, volume status and volume response, right and left heart function, and the function of the heart valves. CONCLUSION: Integrating all echocardiographic findings in a differentiated assessment of the patient's cardiovascular function enables a (patho)physiologically oriented and individualized hemodynamic treatment.


Subject(s)
Echocardiography, Transesophageal , Echocardiography , Anesthesiologists , Heart , Hemodynamics , Humans
3.
J Clin Monit Comput ; 35(2): 229-243, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32458170

ABSTRACT

The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular pathophysiology can be decisive to guide interventions in the intraoperative setting. Various techniques are available to monitor the hemodynamic status of the patient, however due to intrinsic limitations, many of these methods may not be able to directly identify the underlying cause of cardiovascular impairment. Hemodynamic focused echocardiography, as a rapid diagnostic method, offers an excellent opportunity to examine signs of filling impairment, cardiac preload, myocardial contractility and the function of the heart valves. We thus propose a 6-step-echocardiographic approach to assess high-risk patients in order to improve and maintain perioperative DO2. The summary of all echocardiographic based findings allows a differentiated assessment of the patient's cardiovascular function and can thus help guide a (patho)physiological-orientated and individualized hemodynamic therapy.


Subject(s)
Echocardiography , Hemodynamics , Anesthesiologists , Heart , Humans , Monitoring, Physiologic
4.
Anaesthesist ; 69(2): 108-116, 2020 02.
Article in German | MEDLINE | ID: mdl-31802173

ABSTRACT

BACKGROUND: Despite an increasing incidence of patients suffering from acute coronary syndrome (ACS) under simultaneous treatment with direct oral anticoagulants (DOAC), neither sufficient scientific data nor uniform guidelines for the anticoagulation treatment of these patients are currently available. OBJECTIVE: The aim of this study was to determine the current practice of preclinical treatment of ACS in patients under DOAC treatment. MATERIAL AND METHODS: An internet and paper-based survey of emergency physicians, specialists of internal medicine, anesthesiologists, emergency and intensive care physicians was performed concerning the prehospital treatment of ACS in patients under long-term DOAC treatment. RESULTS: Overall, 284 questionnaires were answered. Substantial differences in the current treatment of ACS under long-term DOAC therapy were identified. While 39% of the respondents stated that they administer a combination treatment of heparin and acetylsalicylic acid (ASA), 36% renounced the administration of heparin. If a dose reduction was performed, 71% answered that they reduce the heparin dosage. Also, in cases of ST-segment elevation myocardial infarction 48% of the physicians renounced the administration of heparin. CONCLUSION: In Germany there is currently a heterogeneous practice of emergency treatment of ACS patients under DOAC therapy with respect to the administration of heparin and ASA. Therefore, guidelines of the specialist medical societies should address the prehospital emergency anticoagulation management of ACS in patients under therapy with DOAC, which correspond to the needs of patients and emergency physicians.


Subject(s)
Acute Coronary Syndrome/etiology , Acute Coronary Syndrome/therapy , Anticoagulants/adverse effects , Anticoagulants/administration & dosage , Emergency Medical Services , Germany , Heparin/administration & dosage , Heparin/adverse effects , Humans
5.
Med Klin Intensivmed Notfmed ; 114(1): 15-20, 2019 02.
Article in German | MEDLINE | ID: mdl-28444410

ABSTRACT

BACKGROUND: The fourth edition of the German guideline for the assessment of brain death, published in 2015 by the German Medical Council (Bundesärztekammer), emphasizes the importance of an apnea test. It is also now required under all circumstances of extracorporeal life support. OBJECTIVES: This article is an instruction for the guideline-conforming performance of an apnea test in general and also in cases of extracorporeal life support in different configurations. MATERIALS AND METHODS: A literature review was performed. CONCLUSIONS: The apnea test is an essential part of the bedside examination for the clinical diagnosis of brain death. It is required for all kinds of extracorporeal life support and can be easily performed without endangering the patient. More accurate recommendations for its performance should be considered for the next version of the German guideline for brain death assessment.


Subject(s)
Apnea , Brain Death , Extracorporeal Membrane Oxygenation , Apnea/physiopathology , Brain Death/diagnosis , Humans , Life Support Care
6.
Anaesthesist ; 66(4): 274-282, 2017 Apr.
Article in German | MEDLINE | ID: mdl-28144686

ABSTRACT

The circle system has been in use for more than 100 years, whereas the first clinical application of an anaesthetic reflector was reported just 15 years ago. In the circle system, all breathing gas is rebreathed after carbon dioxide absorption. A reflector, on the other hand, with the breathing gas flowing to and fro, specifically retains the anaesthetic during expiration and resupplies it during the next inspiration. A high reflection efficiency (number of molecules resupplied/number of molecules exhaled, RE 80-90%) decreases consumption. In analogy to the fresh gas flow of a circle system, pulmonary clearance ((1-RE) × minute ventilation) defines the opposition between consumption and control of the concentration.It was not until reflection systems became available that volatile anaesthetics were used routinely in some intensive care units. Their advantages, such as easy handling, and better ventilatory capabilities of intensive care versus anaesthesia ventilators, were basic preconditions for this. Apart from AnaConDa™ (Sedana Medical, Uppsala, Sweden), the new MIRUS™ system (Pall Medical, Dreieich, Germany) represents a second, more sophisticated commercially available system.Organ protective effects, excellent control of sedation, and dose-dependent deep sedation while preserving spontaneous breathing with hardly any accumulation or induction of tolerance, make volatile anaesthetics an interesting alternative, especially for patients needing deep sedation or when intravenous drugs are no longer efficacious.But obviously, the outcome is most important. We know that deep intravenous sedation increases mortality, whereas inhalational sedation could prove beneficial. We now need prospective clinical trials examining mortality, but also the psychological outcome of those most critically ill patients sedated by inhalation or intravenously.


Subject(s)
Deep Sedation/methods , Hypnotics and Sedatives/administration & dosage , Administration, Inhalation , Anesthetics, Inhalation/administration & dosage , Deep Sedation/instrumentation , Humans , Hypnotics and Sedatives/pharmacokinetics , Respiration
8.
Unfallchirurg ; 118(11): 982-6, 2015 Nov.
Article in German | MEDLINE | ID: mdl-25747944

ABSTRACT

In Germany the numbers of penetrating thoracic injuries are rare compared to Anglo-American countries; however, the number of cases has increased in recent years due to an increase in violent incidents. This article reports the case of a patient who suffered such a penetrating thoracic injury after a domestic accident. Operative treatment was performed according to the well-established standard treatment algorithms. Contrary to the initial assessment of the emergency doctor, substantially more severe injuries were found.


Subject(s)
Device Removal/methods , Foreign Bodies/surgery , Glass , Pneumothorax/surgery , Thoracic Injuries/surgery , Wounds, Stab/surgery , Accidental Falls , Aged, 80 and over , Combined Modality Therapy/methods , Diagnosis, Differential , Female , Foreign Bodies/complications , Foreign Bodies/diagnosis , Humans , Multiple Trauma/complications , Multiple Trauma/diagnosis , Multiple Trauma/surgery , Paracentesis , Pneumothorax/diagnosis , Pneumothorax/etiology , Thoracic Injuries/complications , Thoracic Injuries/diagnosis , Treatment Outcome , Wounds, Stab/complications , Wounds, Stab/diagnosis
9.
Br J Anaesth ; 106(4): 475-81, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21205624

ABSTRACT

BACKGROUND: Pulse-contour analysis method (PCM) cardiac output (CO) monitors are increasingly used for CO monitoring during anaesthesia and in the critically ill. Very recently, several systems have been introduced that do not need calibration; among them the pressure recording analytical method (PRAM). Sparse data comparing the accuracy of the PRAM-CO with conventional thermodilution CO (ThD-CO) in cardiac surgery patients are available. METHODS: In this prospective comparison study, paired CO measurements with a pulmonary artery catheter and a PRAM monitoring set were obtained 20-30 min apart (t1, t2) in 23 extubated patients on the first postoperative day after cardiac surgery. Data were analysed by the Bland-Altman method. RESULTS: A total of 46 paired CO measurements (23 for each interval) were collected. The Bland-Altman analysis showed a mean difference (bias) of 0.0 litre min(-1) and limits of agreement (1.96 sd) of 4.53 to -4.54 litre min(-1) [upper 95% confidence interval (CI), 3.26-5.80; lower 95% CI, -5.8 to -3.27]. The percentage error (1.96 sd/mean of the reference method) was 87%. CONCLUSIONS: These results question the reliability of the PRAM technology for the determination of CO in postoperative cardiac surgery patients.


Subject(s)
Cardiac Output/physiology , Cardiac Surgical Procedures , Postoperative Care/methods , Aged , Aged, 80 and over , Blood Pressure/physiology , Cardiac Catheterization , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Prospective Studies , Pulmonary Artery/physiopathology , Reproducibility of Results , Thermodilution/methods
10.
Anaesthesist ; 58(11): 1136-43, 2009 Nov.
Article in German | MEDLINE | ID: mdl-19890615

ABSTRACT

Initially introduced as a rheologic agent for use in intermittent claudication due to peripheral artery disease and in ischemic cerebrovascular disease, the methylxanthine derivative pentoxifylline (PTX) has been shown to possess several anti-inflammatory properties which make this drug an interesting immunomodulating adjunct for the management of patients undergoing cardiac surgery. As an unspecific phosphodiesterase inhibitor PTX ameliorates the inflammatory response following a septic stimulus and blunts organ dysfunction after ischemia-reperfusion injury. Apart from this several small clinical studies have shown that the use of PTX may blunt the inflammatory response induced by cardiac surgery using a cardiopulmonary bypass. Additionally it has been shown that the perioperative application of this drug may improve postoperative function of organs at risk, such as the kidneys and liver.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal , Cardiac Surgical Procedures , Pentoxifylline/therapeutic use , Phosphodiesterase Inhibitors/therapeutic use , Vasodilator Agents/therapeutic use , Humans , Reperfusion Injury/drug therapy , Reperfusion Injury/prevention & control , Sepsis/drug therapy , Sepsis/pathology
11.
Dtsch Med Wochenschr ; 134 Suppl 6: S200-2, 2009 Oct.
Article in German | MEDLINE | ID: mdl-19834841

ABSTRACT

The current enthusiasm with the development of catheter-based aortic valve replacement suggests a critical appraisal of the quality of conventional techniques. Currently surgical treatment of diseased aortic valves includes different methods that can be employed with a low risk. Risk prediction is difficult, the Euroscore largely overestimates mortality. By comparison, there is no evidence that the risk of implantation is reduced by catheter-based implantation. Specific complications (stroke, AV-block, perivalvular leak) are more frequent compared to conventional replacement. Despite the current enthusiasm over the feasibility of catheter-based implantation of hybrid aortic valves they should still be used cautiously.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/standards , Heart Valve Prosthesis/standards , Atrioventricular Block/epidemiology , Europe , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/statistics & numerical data , Humans , Morbidity , Postoperative Complications/epidemiology , Risk Assessment , Stroke/epidemiology
12.
Thorac Cardiovasc Surg ; 57(3): 176-7, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19330760

ABSTRACT

Four days after uncomplicated implantation of a two-chamber pacemaker and a normal postoperative course, a patient was referred to our hospital with left-sided hemothorax and early hemorrhagic shock. Chest X-ray and CT scan were suspicious of a right ventricular lead perforation with additional pericardial and pleural injury. Immediate surgery was performed via a lateral thoracotomy and the perforation was repaired via direct suture. An epimyocardial ventricular lead was implanted simultaneously. The patient made an uneventful recovery.


Subject(s)
Bradycardia/therapy , Cardiac Pacing, Artificial/adverse effects , Heart Injuries/etiology , Heart Ventricles/injuries , Pacemaker, Artificial/adverse effects , Bradycardia/physiopathology , Cardiac Surgical Procedures , Heart Injuries/diagnostic imaging , Heart Injuries/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Hemothorax/etiology , Humans , Male , Middle Aged , Pericardium/injuries , Pleura/injuries , Shock, Hemorrhagic/etiology , Suture Techniques , Thoracotomy , Tomography, X-Ray Computed , Treatment Outcome
13.
Thorac Cardiovasc Surg ; 49(5): 287-90, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11605139

ABSTRACT

OBJECTIVE: The use of fibrin gel, which can be produced from patients' blood, was investigated as an autologous, biodegradable scaffold. A new moulding technique was developed to create a complete aortic root. METHODS: A new moulding technique was generated for the creation of complete valve conduit. On the basis of biomechanical valve design studies, a tricuspid "ventricular" and "aortic" stamp were developed. A silicone-coated aluminum cylinder was used to circumferentially limit the mould. The cell/gel suspension was filled into the mould and polymerization was started. RESULTS: The creation of complex structures such as complete valve conduits is possible with the moulding technique described. With a layer thickness of up to 2 mm, histological investigations showed excellent tissue development with viable fibroblasts surrounded by collagen bundles. CONCLUSION: Fibrin gel unifies many properties of an ideal scaffold: The formation of complex structures is possible, the degradation and polymerization is controllable and the formation of the extracellular matrix is excellent.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Tissue Engineering/methods , Tricuspid Valve , Cell Culture Techniques/methods , Fibrin , Humans , Stress, Mechanical , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...