Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Oral Maxillofac Surg ; 54(6): 619-24, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27068851

ABSTRACT

An important complication during insertion of implants in atrophic mandibles is the fracture that can be induced by preparation of the cavity. We designed this study to identify which configuration of cavities in the interforaminal region was the least likely to fracture. An electromechanical testing machine was used to measure breaking loads of specifically-designed synthetic models of atrophic mandibles. The implant cavities correlated with the common clinical patterns. Intact atrophied synthetic mandibles broke at a mean (SD) load of 729.48 (59.94) N (control group). Models with four different configurations of cavities fractured as follows: two short, wide cavities (8 x 4.2mm) at a mean (SD) load of 569.17 (67.7) N; two long, thin cavities (15 x2.8mm) at a load of 563.40 (62.0) N; four short, wide cavities (8 x 4.2mm) at a load of 667.01 (71.89) N; and four long, thin cavities (15 x 2.8mm) at a load of 409.50 (43.61) N. Biomechanical findings showed that there was a greater risk of fracture of atrophic mandibular models in long, thin implant cavities with more preparation sites. Each cavity prepared for an implant increased the risk of fracture in an atrophic mandible. The risk of fracture is greatest with long, thin cavities.


Subject(s)
Dental Implants , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Alveolar Ridge Augmentation , Dental Implantation, Endosseous , Dental Restoration Failure , Humans , Mandible
2.
Br J Oral Maxillofac Surg ; 53(8): 741-7, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26088156

ABSTRACT

Advantages and disadavantages of the three most commonly-used bone grafts for mandibular reconstruction are widely known, but biomechanical experimental studies are rare. We have done loading tests on cadaveric mandibles reconstructed with fibular, iliac crest, and scapular grafts using 3 different osteosynthesis systems to detect and compare their primary stability. Loading tests were done on mandibles with grafts from the fibula and iliac crest and published previously. A 4.5cm paramedian L-type defect was reconstructed with scapula using 2 monocortical non-locking plates, 2 monocortical locking plates, or a single bicortical locking plate/fracture gap in 18 human cadaveric mandibles. These were loaded on to the "Mandibulator" test bench and the movement of fragments in 3 dimensions was assessed and quantified by a PONTOS® optical measurement system. Comparison of the osteosynthesis groups showed that the miniplate was significantly superior to the 6-hole TriLock® plate for both fibular and iliac crest grafts. The fibular graft gave greater stability than the iliac crest and scapular grafts for all 3 osteosynthesis systems. All bony specimens offered sufficient resistance to mechanical stress within the recognised range of biting forces after mandibular reconstruction, independently of the choice of bone graft and osteosynthesis system used. Anatomical and surgical advantages need to be taken into account when choosing a graft. Stability can be maximised with a fibular graft, and further optimised by enlarging the binding area by using the "double barrel" method. Computer simulated experiments could segregate factors that biased results, such as morphological differences among cadavers.


Subject(s)
Fibula/transplantation , Ilium/transplantation , Mandible/surgery , Mandibular Reconstruction , Scapula/transplantation , Autografts , Biomechanical Phenomena , Bite Force , Bone Plates/statistics & numerical data , Cadaver , Dental Stress Analysis , Humans , Mandible/anatomy & histology , Osteogenesis , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...