Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Med Image Anal ; 19(1): 187-202, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25461337

ABSTRACT

Magnetic Resonance Imaging (MRI), a reference examination for cardiac morphology and function in humans, allows to image the cardiac right ventricle (RV) with high spatial resolution. The segmentation of the RV is a difficult task due to the variable shape of the RV and its ill-defined borders in these images. The aim of this paper is to evaluate several RV segmentation algorithms on common data. More precisely, we report here the results of the Right Ventricle Segmentation Challenge (RVSC), concretized during the MICCAI'12 Conference with an on-site competition. Seven automated and semi-automated methods have been considered, along them three atlas-based methods, two prior based methods, and two prior-free, image-driven methods that make use of cardiac motion. The obtained contours were compared against a manual tracing by an expert cardiac radiologist, taken as a reference, using Dice metric and Hausdorff distance. We herein describe the cardiac data composed of 48 patients, the evaluation protocol and the results. Best results show that an average 80% Dice accuracy and a 1cm Hausdorff distance can be expected from semi-automated algorithms for this challenging task on the datasets, and that an automated algorithm can reach similar performance, at the expense of a high computational burden. Data are now publicly available and the website remains open for new submissions (http://www.litislab.eu/rvsc/).


Subject(s)
Heart Ventricles/pathology , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging, Cine/methods , Pattern Recognition, Automated/methods , Ventricular Dysfunction, Left/pathology , Algorithms , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique
2.
Comput Math Methods Med ; 2013: 547897, 2013.
Article in English | MEDLINE | ID: mdl-24069065

ABSTRACT

The segmentation of organs at risk in CT volumes is a prerequisite for radiotherapy treatment planning. In this paper, we focus on esophagus segmentation, a challenging application since the wall of the esophagus, made of muscle tissue, has very low contrast in CT images. We propose in this paper an original method to segment in thoracic CT scans the 3D esophagus using a skeleton-shape model to guide the segmentation. Our method is composed of two steps: a 3D segmentation by graph cut with skeleton prior, followed by a 2D propagation. Our method yields encouraging results over 6 patients.


Subject(s)
Esophagus/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/statistics & numerical data , Algorithms , Computer Simulation , Humans , Imaging, Three-Dimensional/statistics & numerical data , Lymphoma/diagnostic imaging , Lymphoma/radiotherapy , Radiography, Thoracic/statistics & numerical data , Radiotherapy Planning, Computer-Assisted
3.
Int J Comput Assist Radiol Surg ; 6(5): 573-81, 2011 Sep.
Article in English | MEDLINE | ID: mdl-20848320

ABSTRACT

PURPOSE: Segmenting the cardiac ventricles in magnetic resonance (MR) images is required for cardiac function assessment. Numerous segmentation methods have been developed and applied to MR ventriculography. Quantitative validation of these segmentation methods with ground truth is needed prior to clinical use, but requires manual delineation of hundreds of images. We applied a well-established method to this problem and rigorously validated the results. METHODS: An automatic method based on active contours without edges was used for left and the right ventricle cavity segmentation. A large database of 1,920 MR images obtained from 59 patients who gave informed consent was evaluated. Two standard metrics were used for quantitative error measurement. RESULTS: Segmentation results are comparable to previously reported values in the literature. Since different points in the cardiac cycle and different slice levels were used in this study, a detailed error analysis is possible. Better performance was obtained at end diastole than at end systole, and on mid-ventricular slices than apical slices. Localization of segmentation errors were highlighted through a study of their spatial distribution. CONCLUSIONS: Ventricular segmentation based on region-driven active contours provided satisfactory results in MRI, without the use of a priori knowledge. The study of error distribution allows identification of potential improvements in algorithm performance.


Subject(s)
Heart Ventricles/pathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Pattern Recognition, Automated/methods , Adult , Aged , Algorithms , Cohort Studies , Databases, Factual , Humans , Least-Squares Analysis , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...