Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Forensic Sci ; 53(1): 125-34, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18005009

ABSTRACT

Y-chromosomal short-tandem repeat (Y-STR) amplification has been used in forensic casework at the Bureau of Criminal Apprehension (BCA) Forensic Science Laboratory since 2003. At that time, two separate amplifications were required to type the SWGDAM recommended loci (DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, DYS393, DYS438, and DYS439). The Yfiler kit coamplifies these loci as well as DYS437, DYS448, DYS456, DYS458, DYS635, and Y GATA H4. The Yfiler kit was validated following the internal validations outlined in the SWGDAM revised validation guidelines. Our studies show that 0.125 ng of male DNA will generate a complete 17 locus profile and that as little as 0.06 ng of male DNA yields an average of nine loci. In the male-male mixtures, a complete profile from the minor component was detected up to 1:5 ratio; most of the alleles of the minor component were detected at a 1:10 ratio and more than half the alleles of the minor component were detected at a 1:20 ratio. Complete YSTR profiles were obtained when 500 pg male DNA was mixed with female DNA at ratios up to 1:1000. At ratios of 1:5000 and 1:10,000 (male DNA to female DNA) inhibition of the YSTR amplification was evident. The YSTR results obtained for the adjudicated case samples gave significantly more information than the autosomal results. Our studies demonstrate that the Yfiler kit is extremely sensitive, does not exhibit cross-reactivity with female DNA, successfully types male DNA in the presence of overwhelming amounts of female DNA and is successful in typing actual forensic samples from adjudicated cases.


Subject(s)
Chromosomes, Human, Y , DNA Fingerprinting/instrumentation , Polymerase Chain Reaction/instrumentation , Tandem Repeat Sequences , DNA/genetics , Female , Humans , Male , Sensitivity and Specificity
4.
Forensic Sci Int ; 151(1): 111-24, 2005 Jun 30.
Article in English | MEDLINE | ID: mdl-16156007

ABSTRACT

Y chromosome-specific short tandem repeat (Y-STR) analysis has become another widely accepted tool for human identification. The PowerPlex Y System is a fluorescent multiplex that includes the 12 loci: DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438 and DYS439. This panel of markers incorporates the 9-locus European minimal haplotype (EMH) loci recommended by the International Y-STR User Group and the 11-locus set recommended by the Scientific Working Group on DNA Analysis Methods (SWGDAM). Described here are inter-laboratory results from 17 developmental validation studies of the PowerPlex Y System and include the following results: (a) samples distributed between laboratories and commercial standards produced expected and reproducible haplotypes; (b) use of common amplification and detection instruments were successfully demonstrated; (c) full profiles were obtained with standard 30 and 32 cycle amplification protocols and cycle number (24-28 cycles) could be modified to match different substrates (such as direct amplification of FTA paper); (d) complete profiles were observed with reaction volumes from 6.25 to 50 microL; (e) minimal impact was observed with variation of enzyme concentration; (f) full haplotypes were observed with 0.5-2x primer concentrations; however, relative yield between loci varied with concentration; (g) reduction of magnesium to 1mM (1.5 mM standard) resulted in minimal amplification, while only partial loss of yield was observed with 1.25 mM magnesium; (h) decreasing the annealing temperature by 2-4 degrees C did not generate artifacts or locus dropout and most laboratories observed full amplification with the annealing temperature increased by 2 degrees C and significant locus dropout with a 4 degrees C increase in annealing temperature; (i) amplification of individual loci with primers used in the multiplex produced the same alleles as observed with the multiplex amplification; (j) all laboratories observed full amplification with >or = 125 pg of male template with partial and/or complete profiles observed using 30-62.5 pg of DNA; (k) analysis of < or = 500 ng of female DNA did not yield amplification products; (l) the minor male component of a male/female mixture was observed with < or =1200-fold excess female DNA with the majority of alleles still observed with 10,000-fold excess female; (m) male/male mixtures produced full profiles from the minor contributor with 10-20-fold excess of the major contributor; (n) average stutter for each locus; (o) precision of sizing were determined; (p) human-specificity studies displayed amplification products only with some primate samples; and (q) reanalysis of 102 non-probative casework samples from 65 cases produced results consistent with original findings and in some instances additional identification of a minor male contributor to a male/female mixture was obtained. In general, the PowerPlex Y System was shown to have the sensitivity, specificity and reliability required for forensic DNA analysis.


Subject(s)
Chromosomes, Human, Y , DNA Fingerprinting/standards , Polymerase Chain Reaction/standards , Sex Determination Processes , Tandem Repeat Sequences , Animals , DNA Primers , Female , Genetic Markers , Genotype , Humans , Male , Polymerase Chain Reaction/methods , Reproducibility of Results , Sensitivity and Specificity , Temperature
5.
Forensic Sci Int ; 150(1): 1-15, 2005 May 28.
Article in English | MEDLINE | ID: mdl-15837004

ABSTRACT

A total of 2443 male individuals, previously typed for the 13 CODIS STR loci, distributed across the five North American population groups African American, Asian, Caucasian, Hispanic, and Native American were typed for the Y-STR loci DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438 and DYS439 using the PowerPlex Y System. All population samples were highly polymorphic for the 12 Y-STR loci with the marker DYS385a/b being the most polymorphic across all sample populations. The Native American population groups demonstrated the lowest genetic diversity, most notably at the DYS393 and DYS437 loci. Almost all of the 12-locus haplotypes observed in the sample populations were represented only once in the database. Haplotype diversities were greater than 99.6% for the African Americans, Caucasians, Hispanics, and Asians. The Native Americans had the lowest haplotype diversities (Apaches, 97.0%; Navajo, 98.1%). Population substructure effects were greater for Y-haplotypes, compared with that for the autosomal loci. For the apportionment of variance for the 12 Y-STRs, the within sample population variation was the largest component (>98% for each major population group and approximately 97% in Native Americans), and the variance component contributed by the major population groups was less than the individual component, but much greater than among sample populations within a major group (11.79% versus 1.02% for African Americans/Caucasians/Hispanics and 15.35% versus 1.25% for all five major populations). When each major population is analyzed individually, the R(ST) values were low but showed significant among group heterogeneity. In 692 confirmed father-son pairs, 14 mutation events were observed with the average rate of 1.57x10(-3)/locus/generation (a 95% confidence bound of 0.83x10(-3) to 2.69x10(-3)). Since the Y-STR loci reside on the non-recombining region of the Y chromosome, the counting method is one approach suggested for conveying an estimate of the rarity of the Y-haplotype. Because the Y-STR loci are not all in disequilibrium to the same extent, the counting method is a very conservative approach. The data also support that autosomal STR frequencies can be multiplied by the upper bound frequency estimate of a Y-haplotype in the individual population group or those pooled into major population groups (i.e., Caucasian, African American, Hispanic, and Asian). These analyses support use of the haplotype population data for estimating Y-STR profile frequencies for populations residing in North America.


Subject(s)
Chromosomes, Human, Y/genetics , Haplotypes , Population Groups/genetics , Tandem Repeat Sequences , Canada , Genetics, Population , Humans , United States
6.
Forensic Sci Int ; 148(1): 1-14, 2005 Feb 10.
Article in English | MEDLINE | ID: mdl-15607584

ABSTRACT

Y chromosome-specific short tandem repeat (Y-STR) analysis has become another widely accepted tool for human identification. The PowerPlex Y System is a fluorescent multiplex that includes the 12 loci: DYS19, DYS385a/b, DYS389I/II, DYS390, DYS391, DYS392, DYS393, DYS437, DYS438 and DYS439. This panel of markers incorporates the 9-locus European minimal haplotype (EMH) loci recommended by the International Y-STR User Group and the 11-locus set recommended by the Scientific Working Group on DNA Analysis Methods (SWGDAM). Described here are inter-laboratory results from 17 developmental validation studies of the PowerPlex Y System and include the following results: (a) samples distributed between laboratories and commercial standards produced expected and reproducible haplotypes; (b) use of common amplification and detection instruments were successfully demonstrated; (c) full profiles were obtained with standard 30 and 32 cycle amplification protocols and cycle number (24-28 cycles) could be modified to match different substrates (such as direct amplification of FTA paper); (d) complete profiles were observed with reaction volumes from 6.25 to 50 microL; (e) minimal impact was observed with variation of enzyme concentration; (f) full haplotypes were observed with 0.5-2x primer concentrations; however, relative yield between loci varied with concentration; (g) reduction of magnesium to 1mM (1.5 mM standard) resulted in minimal amplification, while only partial loss of yield was observed with 1.25 mM magnesium; (h) decreasing the annealing temperature by 2-4 degrees C did not generate artifacts or locus dropout and most laboratories observed full amplification with the annealing temperature increased by 2 degrees C and significant locus dropout with a 4 degrees C increase in annealing temperature; (i) amplification of individual loci with primers used in the multiplex produced the same alleles as observed with the multiplex amplification; (j) all laboratories observed full amplification with >or = 125 pg of male template with partial and/or complete profiles observed using 30-62.5 pg of DNA; (k) analysis of < or = 500 ng of female DNA did not yield amplification products; (l) the minor male component of a male/female mixture was observed with < or =1200-fold excess female DNA with the majority of alleles still observed with 10,000-fold excess female; (m) male/male mixtures produced full profiles from the minor contributor with 10-20-fold excess of the major contributor; (n) average stutter for each locus; (o) precision of sizing were determined; (p) human-specificity studies displayed amplification products only with some primate samples; and (q) reanalysis of 102 non-probative casework samples from 65 cases produced results consistent with original findings and in some instances additional identification of a minor male contributor to a male/female mixture was obtained. In general, the PowerPlex Y System was shown to have the sensitivity, specificity and reliability required for forensic DNA analysis.


Subject(s)
Chromosomes, Human, Y , DNA Fingerprinting/standards , Polymerase Chain Reaction/standards , Sex Determination Processes , Tandem Repeat Sequences , Animals , DNA Primers , Female , Genetic Markers , Genotype , Humans , Male , Polymerase Chain Reaction/methods , Reproducibility of Results , Sensitivity and Specificity , Temperature
7.
J Forensic Sci ; 49(6): 1278-90, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15568701

ABSTRACT

The Y-PLEX 12 system, developed for use in human identification, enables simultaneous amplification of eleven polymorphic short tandem repeat (STR) loci, namely DYS392, DYS390, DYS385 a/b, DYS393, DYS389I, DYS391, DYS389II, DYS 19, DYS439 and DYS438, residing on the Y chromosome and Amelogenin. Amelogenin provides results for gender identification and serves as internal control for PCR. The validation studies were performed according to the DNA Advisory Board's (DAB) Quality Assurance Standards. The minimal sensitivity of the Y-PLEX 12 system was 0.1 ng of male DNA. The mean stutter values ranged between 3.76-15.72%. A full male profile was observed in mixture samples containing 0.5 ng of male DNA and up to 400 ng of female DNA. Amelogenin did not adversely affect the amplification of Y-STRs in mixture samples containing male and female DNA. The primers for the Y-STR loci present in Y-PLEX 12 are specific for human DNA and some higher primates. None of the primate samples tested provided a complete profile at all 11 Y-STR loci amplified with the Y-PLEX 12 system. Y-PLEX 12 is a sensitive, valid, reliable, and robust multiplex system for forensic analysis, and it can be used in human forensic and male lineage identification cases.


Subject(s)
Chromosomes, Human, Y , DNA Fingerprinting/methods , Polymerase Chain Reaction/methods , Sex Determination Processes , Tandem Repeat Sequences , Amelogenin , Animals , DNA Primers , Dental Enamel Proteins/genetics , Female , Humans , Male , Polymorphism, Genetic , Sequence Analysis, DNA , Tooth Germ
8.
J Forensic Sci ; 48(5): 985-1000, 2003 Sep.
Article in English | MEDLINE | ID: mdl-14535662

ABSTRACT

A genotyping system, Y-PLEX 5, has been developed for use in human identification. The Y-PLEX 5 enables simultaneous amplification of five polymorphic short tandem repeat (STR) loci residing on the Y-chromosome, which are DYS389I, DYS389II, DYS439, DYS438, and DYS392. As little as 0.1 ng of template DNA can be used for analysis. The specificity of the amplification reaction enabled analysis of male DNA in a male: female DNA mixture at a ratio of 1:600. Mean stutter values ranged from 3.60-10.97%. Among the different primates investigated, the DNA from orangutan exhibited amplification at DYS438 locus and from gorilla at DYS439 and DYS438 loci. The DNA from cat, dog, and horse did not yield any amplified product. Studies on development of the genotyping system, generation and description of the allelic ladder, and validation of the multiplex PCR as per the FBI Director's Quality Assurance Standards were carried out. Y-STR allele and haplotype frequencies in two populations were generated. The data indicate that the Y-PLEX 5 genotyping system is sensitive and reliable, and can be used in human forensic and male lineage identification cases.


Subject(s)
DNA Fingerprinting/methods , Polymerase Chain Reaction/methods , Tandem Repeat Sequences , Y Chromosome , Alleles , Animals , Black People/genetics , Cats , DNA/analysis , DNA Primers , Female , Forensic Medicine/methods , Genotype , Hominidae , Horses , Humans , Male , Papio , Polymorphism, Genetic , Reproducibility of Results , White People/genetics
9.
J Forensic Sci ; 48(1): 93-103, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12570206

ABSTRACT

A Y-chromosome multiplex polymerase chain reaction (PCR) amplification kit, known as Y-PLEX 6, has been developed for use in human identification. The Y-PLEX 6 kit enables simultaneous amplification of six polymorphic short tandem repeat (STR) loci located on the non-recombinant region of the human Y-chromosome. These loci are: DYS393, DYS19, DYS38911, DYS390, DYS391, and DYS385. Our studies show that as little as 0.2 ng of template DNA can be used for analysis. The specificity of the amplification reaction enabled analysis of male DNA in a male:female DNA mixture at a ratio of 1:125. Among the six Y-STR loci, the maximum mean stutter percentage was 11.9 for allele at DYS38911 locus. Attempts at amplification of DNA from various animal sources revealed that the Y-PLEX 6 primers are human specific. Details of the development of the kit, generation and description of the allelic ladders, and validation of the multiplex PCR are presented. In addition, Y-STR allele and haplotype frequencies in three populations have been investigated. The data indicate that results obtained using the Y-PLEX 6 kit are robust, sensitive, and reliable and can be used in human forensic and male lineage identification cases.


Subject(s)
DNA Fingerprinting/methods , Polymerase Chain Reaction/methods , Tandem Repeat Sequences , Y Chromosome , Animals , Female , Forensic Medicine/methods , Genetics, Population , Genotype , Haplotypes , Humans , Male , Racial Groups/genetics , Sensitivity and Specificity , Sex Determination Processes
SELECTION OF CITATIONS
SEARCH DETAIL
...