1.
Int J Cardiovasc Imaging ; 38(10): 2227-2234, 2022 Oct.
Article in English | MEDLINE | ID: mdl-37726457

ABSTRACT

To determine if coronary artery calcium (CAC) scoring using computed tomography at 80 kilovolt-peak (kVp) and 70-kVp and tube voltage-adapted scoring-thresholds allow for accurate risk stratification as compared to the standard 120-kVp protocol. We prospectively included 170 patients who underwent standard CAC scanning at 120-kVp and 200 milliamperes and additional scans with 80-kVp and 70-kVp tube voltage with adapted tube current to normalize image noise across scans. Novel kVp-adapted thresholds were applied to calculate CAC scores from the low-kVp scans and were compared to those from standard 120-kVp scans by assessing risk reclassification rates and agreement using Kendall's rank correlation coefficients (Τb) for risk categories bounded by 0, 1, 100, and 400. Interreader reclassification rates for the 120-kVp scans were assessed. Agreement for risk classification obtained from 80-kVp and 70-kVp scans as compared to 120-kVp was good (Τb = 0.967 and 0.915, respectively; both p < 0.001) with reclassification rates of 7.1% and 17.2%, respectively, mostly towards a lower risk category. By comparison, the interreader reclassification rate was 4.1% (Τb = 0.980, p < 0.001). Reclassification rates were dependent on body mass index (BMI) with 7.1% and 13.6% reclassifications for the 80-kVp and 70-kVp scans, respectively, in patients with a BMI < 30 kg/m2 (n = 140), and 2.9% and 7.4%, respectively, in patients with a BMI < 25 kg/m2 (n = 68). Mean effective radiation dose from the 120-kVp, the 80-kVp, and 70-kVp scans was 0.54 ± 0.03, 0.42 ± 0.02, and 0.26 ± 0.02 millisieverts. CAC scoring with reduced tube voltage allows for accurate risk stratification if kVp-adapted thresholds for calculation of CAC scores are applied.ClinicalTrials.gov NCT03637231.


Subject(s)
Calcium , Coronary Vessels , Humans , Coronary Vessels/diagnostic imaging , Predictive Value of Tests , Risk Assessment , Tomography
2.
J Nucl Cardiol ; 28(4): 1364-1373, 2021 Aug.
Article in English | MEDLINE | ID: mdl-31399902

ABSTRACT

PURPOSE: A surface 12-lead electrocardiogram (ECG) is widely available, fast, inexpensive, and safe. However, its value to predict a true myocardial scar in patients with ischemic cardiomyopathy (ICM) has not been studied extensively yet. This study was conducted to assess whether Q waves on resting surface 12-lead ECG are predictive of non-viable myocardium in patients with ICM. METHODS: We analyzed resting ECGs of 149 patients with ICM undergoing cardiac positron emission tomography (PET) with 13N-ammonia (NH3) and 18F-fluorodeoxyglucose (FDG) at our institution. Pathological Q waves and QS complexes were assigned to one of three coronary artery territories and compared to the PET findings. Myocardial scar was defined as 2 or more contiguous myocardial segments with an average (matched) reduction of NH3 and FDG uptake <50% of the maximum value. RESULTS: Pathological Q waves had a sensitivity and specificity of 70% and 40%, respectively, and a PPV and NPV of 37% and 73%, respectively, to detect myocardial scar on FDG PET. For QS complexes, sensitivity and specificity were 46% and 59%, respectively, and PPV and NPV were 36% and 68%, respectively. Sensitivity was lower, but specificity was significantly higher in both the LCX and RCA compared to the LAD territory (p<0.001), particularly for QS complexes. CONCLUSION: Pathological Q waves on resting 12-lead ECG have poor or at best moderate sensitivity and specificity to detect myocardial scar on FDG PET. These findings support the use of more advanced imaging techniques to assess myocardial viability in ICM.


Subject(s)
Cicatrix/diagnostic imaging , Electrocardiography , Heart Failure/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Positron-Emission Tomography , Aged , Cicatrix/etiology , Female , Fluorodeoxyglucose F18 , Heart Failure/complications , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Nitrogen Radioisotopes , Retrospective Studies , Sensitivity and Specificity
3.
J Nucl Cardiol ; 27(2): 452-460, 2020 04.
Article in English | MEDLINE | ID: mdl-30109592

ABSTRACT

BACKGROUND: A reduction in left ventricular apical tracer uptake (apical thinning) is frequently observed in myocardial perfusion imaging (MPI), yet its cause remains a matter of debate, particularly in perfusion emission tomography (PET). This analysis sought to determine whether apical thinning in PET-MPI is attributable to true anatomical thinning of the left ventricular apical myocardium. METHODS AND RESULTS: We retrospectively analyzed 57 patients without any history or signs of apical myocardial infarction who underwent rest PET-MPI with 13N-ammonia and contrast-enhanced cardiac computed tomography (CT). Semi-quantitative normalized percent apical 13N-ammonia uptake at rest, myocardial blood flow (MBF), and k2 wash-out rate constants were compared to apical myocardial wall thickness measurements derived from CT and base-to-apex gradients were calculated. Apical thinning was found in 93% of patients and in 74% when analysis of normalized apical tracer uptake was confined to end-systole. No significant correlation was found between apical myocardial thickness and apical tracer uptake (r = - 0.080, P = .553), MBF (r = - 0.211, P = .115), or k2 wash-out rate (r = - 0.023, P = .872), nor between apical myocardial thickness and any gradients. A statistically significant but small difference in apical myocardial thickness was observed in patients with moderately to severely reduced apical tracer uptake vs patients with normal to mildly reduced uptake (4.3 ± 0.7 mm vs 4.7 ± 0.7 mm; P = .043). CONCLUSIONS: Apical thinning is a highly prevalent finding during 13N-ammonia PET-MPI that is not solely attributable to true anatomical apical wall thickness or the partial volume effect. Other factors that yet need to be identified seem to have a more prominent impact.


Subject(s)
Heart Ventricles/diagnostic imaging , Heart/diagnostic imaging , Myocardial Perfusion Imaging/methods , Myocardium/pathology , Positron-Emission Tomography/methods , Aged , Ammonia , Contrast Media , Coronary Circulation , Female , Heart/physiopathology , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Nitrogen Radioisotopes , Retrospective Studies , Tomography, X-Ray Computed/methods
4.
J Nucl Cardiol ; 27(1): 228-237, 2020 02.
Article in English | MEDLINE | ID: mdl-29923103

ABSTRACT

BACKGROUND: The applicability of ultra-low-dose computed tomography (CT) for attenuation correction (AC) of single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) remains elusive. METHODS AND RESULTS: One-hundred patients underwent one-day 99mTc-tetrofosmin stress-rest MPI and non-contrast enhanced cardiac CT with 120, 80, and 70 kilovolt peak (kVp) tube voltage and tube current of 200 milliamperes for creation of AC maps. Normalized percent myocardial uptake from SPECT-MPI using 80 kVp scans for AC showed excellent correlation vs AC from 120 kVp scans for stress [intraclass correlation (ICC) = 0.988, 95% CI = 0.986-0.989, P < .001] and rest (ICC = 0.985, 95% CI = 0.983-0.987, P < .001) with narrow Bland-Altman limits of agreement (BA-LA) (- 5.3% to 4.5% and - 5.4% to 4.4%, respectively) and minimal bias (- 0.4% and - 0.5%, respectively). Correlation of AC SPECT-MPI based on 70 vs 120 kVp scans was excellent for stress (ICC = 0.988, 95% CI = 0.986-0.989, P < .001) and rest (ICC = 0.986, 95% CI = 0.984-0.987, P < .001) with narrow BA-LA (- 5.3% to 4.4% and - 5.2% to 4.5%, respectively) and small bias (- 0.4% and - 0.3%, respectively). Mean effective radiation dose for the 120, 80 and 70 kVp scans were 0.58 ± 0.07, 0.19 ± 0.02, and 0.12 ± 0.01 mSv, respectively. CONCLUSIONS: Attenuation maps for MPI obtained from ultra-low radiation dose CT scans are interchangeable with attenuation maps from standard-dose CT while offering a substantial reduction in radiation dose exposure.


Subject(s)
Heart Diseases/diagnostic imaging , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed , Aged , Cadmium , Female , Humans , Male , Middle Aged , Organophosphorus Compounds , Organotechnetium Compounds , Prospective Studies , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Tellurium , Zinc
5.
Eur Heart J Cardiovasc Imaging ; 19(12): 1362-1371, 2018 12 01.
Article in English | MEDLINE | ID: mdl-29432592

ABSTRACT

Aims: To determine if tube-adapted thresholds for coronary artery calcium (CAC) scoring by computed tomography at 80 kilovolt-peak (kVp) tube voltage and 70-kVp yield comparable results to the standard 120-kVp protocol. Methods and results: We prospectively included 103 patients who underwent standard scanning with 120-kVp tube voltage and additional scans with 80 kVp and 70 kVp. Mean body mass index (BMI) was 27.9 ± 5.1 kg/m2. For the lowered tube voltages, we applied novel kVp-adapted thresholds for calculation of CAC scores and compared them with standard 120-kVp scans using intraclass correlation and Bland-Altman (BA) analysis. Furthermore, risk-class (CAC score 0/1-10/11-100/101-400/>400) changes were assessed. Median CAC score from 120-kVp scans was 212 (interquartile range 25-901). Thirteen (12.6%) patients had zero CAC. Using the novel kVp-adapted thresholds, CAC scores derived from 80-kVp scans showed excellent correlation (r = 0.994, P < 0.001) with standard 120-kVp scans with BA limits of agreement of -235 (-39.5%) to 172 (28.9%). Similarly, for 70-kVp scans, correlation was excellent (r = 0.972, P < 0.001) but with broader limits of agreement of -476 (-85.0%) to 270 (48.2%). Only 2 (2.8%) reclassifications were observed for the 80-kVp scans in patients with a BMI <30 kg/m2 (n = 71), and 2 (6.1%) for the 70-kVp scans in patients with a BMI <25 kg/m2 (n = 33). Mean effective radiation dose was 0.60 ± 0.07 millisieverts (mSv), 0.19 ± 0.02 mSv, and 0.12 ± 0.01 mSv for the 120-kVp, 80-kVp, and 70-kVp scans, respectively. Conclusion: The present study suggests that CAC scoring with reduced peak tube voltage is accurate if kVp-adapted thresholds for calculation of CAC scores are applied while offering a substantial further radiation dose reduction.


Subject(s)
Computed Tomography Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Radiation Dosage , Vascular Calcification/diagnostic imaging , Aged , Analysis of Variance , Calcium/metabolism , Cohort Studies , Coronary Angiography/methods , Disease Progression , Female , Follow-Up Studies , Hospitals, University , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Radiation Exposure/prevention & control , Risk Assessment , Severity of Illness Index , Switzerland , Vascular Calcification/pathology