Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Article in English | MEDLINE | ID: mdl-38529637

ABSTRACT

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Heart Valve Prosthesis , Prosthesis Design , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Male , Female , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Calcinosis/diagnostic imaging , Calcinosis/surgery , Treatment Outcome , Risk Factors , Time Factors , Risk Assessment , Retrospective Studies , Propensity Score , Recovery of Function , Balloon Valvuloplasty/adverse effects , Hemodynamics
2.
Front Cardiovasc Med ; 11: 1263905, 2024.
Article in English | MEDLINE | ID: mdl-38343872

ABSTRACT

In a female patient with acute cardiac decompensation, an auxiliary finding of a giant left atrium emerged. The surgical therapy of the atrial reduction, in addition to a mitral valve replacement and a coronary artery bypass grafting, is hereby presented.

4.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38084735

ABSTRACT

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Registries , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects
5.
Cardiol J ; 30(6): 1003-1009, 2023.
Article in English | MEDLINE | ID: mdl-37964645

ABSTRACT

BACKGROUND: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive direct artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. METHODS: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). RESULTS: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). CONCLUSIONS: Minimally invasive direct coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal.


Subject(s)
Coronary Artery Disease , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Artery Bypass/methods , Follow-Up Studies , Treatment Outcome , Myocardial Revascularization/methods
6.
J Clin Med ; 12(12)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37373693

ABSTRACT

BACKGROUND: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. AIMS: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. METHODS: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. RESULTS: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). CONCLUSIONS: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.

7.
Diagnostics (Basel) ; 13(7)2023 Apr 06.
Article in English | MEDLINE | ID: mdl-37046575

ABSTRACT

OBJECTIVES: This study examined the prognostic value of the get-with-the-guidelines heart-failure risk score (GWTG-HF) on mortality in patients with low-flow-low-gradient aortic valve stenosis (LFLG-AS) after transcatheter aortic valve implantation (TAVI). BACKGROUND: Data on feasibility of TAVI and mortality prediction in the LFLG-AS population are scarce. Clinical risk assessment in this particular population is difficult, and a score has not yet been established for this purpose. METHODS: A total of 212 heart failure (HF) patients with real LFLG-AS were enrolled. Patients were classified into low-risk (n = 108), intermediate-risk (n = 90) and high-risk (n = 14) groups calculated by the GWTG-HF score. Clinical outcomes of cardiovascular events according to Valve Academic Research Consortium (VARC-2) recommendations and composite endpoint of death and hospitalization for heart failure (HHF) were assessed at discharge and 1 year of follow-up. RESULTS: Baseline parameters of the groups showed a median age of 81.0 years [77.0; 84.0] (79.0 vs. 82.0 vs. 86.0, respectively p < 0.001), median EuroSCORE II of 6.6 [4.3; 10.7] (5.5 vs. 7.2 vs. 9.1, p = 0.004) and median indexed stroke volume of 26.7 mL/m2 [22.0; 31.0] (28.2 vs. 25.8 vs. 25.0, p = 0.004). The groups significantly differed at follow-up in terms of all-cause mortality (10.2 vs. 21.1 vs. 28.6%; p < 0.035). There was no difference in intrahospital event rate (VARC). Postprocedural mean gradients were lower in high-risk group (7.0 vs. 7.0 vs. 5.0 mmHg, p = 0.011). No differences in postprocedural aortic valve area (1.9 vs. 1.7 vs. 1.9 cm2, p = 0.518) or rate of device failure (5.6 vs. 6.8 vs. 7.7%, p = 0.731) could be observed. After adjustment for known predictors, the GWTG score (HR 1.07 [1.01-1.14], p = 0.030) as well as pacemaker implantation (HR 3.97 [1.34-11.75], p = 0.013) turned out to be possible predictors for mortality. An increase in stroke volume index (SVI) was, in contrast, protective (HR 0.90 [0.83-0.97]; p = 0.006). CONCLUSIONS: The GWTG score may predict mortality after TAVI in LFLG-AS HF patients. Interestingly, all groups showed similar intrahospital event and mortality rates, independent of calculated mortality risk. Low SVI and new conduction disturbances associated with PPI after THV implantation had negative impact on mid-term outcome in post-TAVI HF-patients.

8.
J Clin Med ; 12(3)2023 Jan 26.
Article in English | MEDLINE | ID: mdl-36769593

ABSTRACT

BACKGROUND: Severe calcification of the ascending aorta increases the peri-operative risk for neurological complications in patients with severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) seems to be an optimal treatment option in these patients. However, the impact of the extent of aortic calcification on procedural and neurological outcomes during TAVI is unclear. METHODS: Data from 3010 patients with severe native aortic valve stenosis treated with ACURATE neo/neo2 from May 2012 to July 2022 were evaluated and matched by 2-to-1 nearest-neighbor matching to identify one patient with porcelain aorta (PA) (n = 492) compared with two patients without PA (n = 984). PA was additionally subdivided into circumferential (classic PA) (n = 89; 3.0%) and non-circumferential (partial PA) (n = 403; 13.4%) calcification. We compared outcomes according to VARC-3 criteria among patients with and without PA and identified predictors for occurrence of stroke in the overall population. RESULTS: Technical success (88.5% vs. 87.4%, p = 0.589) and device success at 30 days (82.3% vs. 81.5%, p = 0.755) after transcatheter ACURATE neo/neo2 implantation according to VARC-3 definition was high and did not differ between non-calcified aortas or PA. The rate of in-hospital complications according to VARC-3-definitions was low in both groups. Rates of all stroke (3.2% (n = 31) vs. 2.6% (n = 13), p = 0.705) or transitory ischemic attacks (1.1% vs. 1.2%, p = 1.000) did not differ significantly. Thirty-day all-cause mortality did not differ (3.0% vs. 3.2%, RR 1.1; p = 0.775). Overall device migration/embolization (OR 5.0 [2.10;11.87]), severe bleeding (OR 1.79 [1.11;2.89]), and major structural cardiac complications (OR 3.37 [1.32;8.57]) were identified as independent predictors for in-hospital stroke in a multivariate analysis after implantation of ACURATE neo/neo2. CONCLUSION: A porcelain aorta does not increase the risk of neurological complications after transfemoral ACURATE neo/neo2 implantation. Based on these findings, transfemoral ACURATE neo/neo2 implantation is safe in these particularly vulnerable patients.

9.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36543448

ABSTRACT

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Stroke Volume , Propensity Score , Ventricular Function, Left , Treatment Outcome , Cardiac Catheterization/adverse effects
11.
J Invasive Cardiol ; 34(11): E804-E810, 2022 11.
Article in English | MEDLINE | ID: mdl-36269158

ABSTRACT

BACKGROUND: Few data exist on immediate outcomes of the next-generation Acurate neo2 prosthesis (Boston Scientific), which is distinguished by an active sealing mechanism. We sought to determine procedural outcomes of transfemoral transcatheter aortic valve replacement using the neo2 in comparison with its predecessor, the Acurate neo. METHODS: In this retrospective analysis, consecutive neo2 and neo cases were compared from 2 high-volume centers. The primary outcome of interest was the rate of relevant paravalvular regurgitation (PVR), defined as PVR ≥ moderate, or valve-in-valve and/or surgical aortic valve replacement for PVR ≥ moderate. Secondary outcomes of interest were assessed according to Valve Academic Research Consortium (VARC)-3 criteria. Logistic regression analysis was used to identify predictors of relevant PVR. RESULTS: A total of 810 neo2 and 2055 neo cases comprised the study cohort. The rate of relevant PVR was significantly lower in the neo2 group (2.7% vs 4.5%; P=.04). The technical success rate was numerically higher in the neo2 group (91.5% vs 89.3%; P=.10) and the rate of device success at 30 days was significantly higher (86.5% vs 82.9%; P=.02). In the neo group, a greater amount of aortic valve calcification (AVC), the presence of eccentric AVC, less oversizing, and a higher sinotubular junction annulus index were predictors of relevant PVR, whereas in the neo2 population only the presence of eccentric AVC, less oversizing, and a higher sinotubular junction annulus index was predictive. CONCLUSION: The neo2 valve shows superior outcomes over the neo valve, with a lower burden of PVR and a higher device success rate at 30 days.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prosthesis Design , Retrospective Studies , Treatment Outcome
12.
J Clin Med ; 11(18)2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36142960

ABSTRACT

BACKGROUND: Self-expanding transcatheter valves (THV) seem superior to balloon-expanding valves in regard to the incidence of prosthesis-patient mismatch (PPM). Data on the occurrence of PPM with the ACURATE neo/neo2 system as a representative of self-expanding prostheses in very small annuli, even below the applicable instructions for use (IFU), are scarce. METHODS: Data from 654 patients with severe native aortic stenosis treated with the smallest size ACURATE neo/neo2 valve (size S, 23 mm) at two German high-volume centers from 06/2012 to 12/2021 were evaluated. We compared clinical and hemodynamic outcomes among patients with implantation in adherence to the recommended sizing (on-label n = 529) and below the recommended sizing range (off-label n = 125) and identified predictors for PPM in the overall population. BMI-adjusted PPM was defined according to VARC-3 recommendations. RESULTS: Post-procedure, the mean gradient (10.0 mmHg vs. 9.0 mmHg, p = 0.834) and the rate of paravalvular leakage (PVL) ≥ moderate (3.2% vs. 2.8%, p = 0.770) were similar between on-label and off-label implantations. The rate of moderate to severe PPM (24%) was comparably low in ACURATE neo/neo2 S, with a very low proportion of severe PPM whether implanted off- or on-label (4.9% vs. 3.8%, p = 0.552). Thirty-day all-cause mortality was higher among patients with off-label implantations (6.5% vs. 2.3%, p = 0.036). In the subgroup of these patients, no device-related deaths occurred, and cardiac causes did not differ (each 5). Besides small annulus area and high BMI, a multivariate analysis identified a greater cover index (OR 3.26), deep implantation (OR 2.25) and severe calcification (OR 2.07) as independent predictors of PPM. CONCLUSIONS: The ACURATE neo/neo2 S subgroup shows a convincing hemodynamic outcome according to low mean gradient even outside the previous IFUs without a relevant increase in the rate of PVL or PPM. In addition to known factors such as annulus area and BMI, potential predictors for PPM are severe annulus calcification and implantation depth. Nevertheless, the ACURATE neo/neo2 system seems to be a reliable option in patients with very small annuli.

13.
J Clin Med ; 11(14)2022 Jul 21.
Article in English | MEDLINE | ID: mdl-35887990

ABSTRACT

BACKGROUND: During the last years, several transcatheter aortic heart valves entered the clinical market and are commercially available. The prostheses differ regarding several technical and functional aspects. However, little is known regarding head-to-head comparative data of the ACURATE neo and the PORTICO valve prostheses. OBJECTIVES: The aim of this study was to compare two self-expanding transcatheter aortic heart valves (THV), the ACURATE neo and the PORTICO, with regard to in-hospital and 30-day outcomes, as well as early device failures. METHODS: A total of 1591 consecutive patients with severe native aortic valve stenosis from two centers were included in the analyses and matched by 1:1 nearest neighbor matching to identify one patient treated with PORTICO (n = 344) for each patient treated with ACURATE neo (n = 344). RESULTS: In-hospital complications were comparable between both valves, including any kind of stroke (ACURATE neo = 3.5% vs. PORTICO = 3.8%; p = 1.0), major vascular complications (ACURATE neo = 4.5% vs. PORTICO = 5.4%; p = 0.99) or life-threatening bleeding (ACURATE neo = 1% vs. PORTICO = 2%; p = 0.68). The rate of device failure defined by the VARC-2 criteria were comparable, including elevated gradients and moderate-to-severe paravalvular leakage (ACURATE neo = 7.3% vs. PORTICO = 7.6%; p = 1.0). However, the need for permanent pacemaker implantation (PPI) was significantly more frequent after the use of PORTICO THV (9.5% vs. 18.7%; p = 0.002). CONCLUSIONS: In this two-center case-matched comparison, short-term clinical and hemodynamic outcomes showed comparable results between PORTICO and ACURATE neo prostheses. However, PORTICO was associated with a significant higher incidence of PPI.

14.
J Cardiovasc Med (Hagerstown) ; 23(8): 519-523, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35905002

ABSTRACT

AIMS: Patients with pulmonary embolism (PE) and contraindications for or failed thrombolysis are at the highest risk for PE-related fatal events. These patients may benefit from surgical embolectomy, but data concerning this approach are still limited. METHODS: The method used here was retrospective data analysis of 103 patients who underwent surgical embolectomy from 2002 to 2020 at our department. RESULTS: Mean age was 58.4 (±15.1) years. Fifty-eight (56.3%) patients had undergone recent surgery; the surgery was tumor associated in 32 (31.1%) cases. Thirty (29.1%) patients had to be resuscitated due to PE, and 13 (12.6%) patients underwent thrombolysis prior to pulmonary embolectomy. Fifteen (14.5%) patients were placed on extra corporeal membrane oxygenation (ECMO) peri-operatively. Five patients (4.9%) died intra-operatively. Neurological symptoms occurred in four patients (3.9%). Thirty-day mortality was 23.3% ( n  = 24). Re-thoracotomy due to bleeding was necessary in 12 (11.6%) patients. This parameter was also identified as an independent risk factor for mortality. CONCLUSION: Surgical pulmonary embolectomy resulted in survival of the majority of patients with PE and contraindications for or failed thrombolysis. Given the excessive mortality when left untreated, an operative approach should become a routine part of discussions concerning alternative treatment options for these patients.


Subject(s)
Pulmonary Embolism , Thrombolytic Therapy , Acute Disease , Embolectomy/adverse effects , Embolectomy/methods , Humans , Middle Aged , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/surgery , Retrospective Studies , Thrombolytic Therapy/adverse effects , Treatment Outcome
15.
Clin Res Cardiol ; 111(8): 924-933, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35362737

ABSTRACT

BACKGROUND: Based on the results of several recent randomized trials, European and American guidelines on valvular heart disease management have substantially expanded the indications for transcatheter aortic valve implantation (TAVI). We present an all-comer data on peri-operative risk profile and in-hospital outcomes from Germany for patients treated by TAVI or isolated surgical aortic valve replacement (iSAVR) in 2020, providing an opportunity to compare study data with data from daily clinical practice. METHODS: Data concerning all isolated aortic valve procedures performed in Germany in 2020 were retrieved from the mandatory nationwide quality control program. Expected mortality was calculated with the annually revised German Aortic valve score (AKL-score) based on the data of either catheter-based (AKL-CATH) or isolated surgical (AKL-CHIR) aortic valve replacement in Germany from the previous year (2019). RESULTS: In 2020 21,903 TAVI procedures (20,810 transvascular (TV; vs. 2019: 22.973; - 9.4%), 1093 transapical (TA; vs. 2019: 1413; - 22.6%)) and 6144 (vs. 2019 7905; - 22.5%) iSAVR were performed in Germany. Patients who received TAVI showed a significantly higher perioperative risk profile than patients undergoing iSAVR based on older age and more severe co-morbidities. While in-hospital mortality after TAVI (2.3%) was numerically lower than in 2019 (2.5%), this difference was not significant (p = 0.11). In-hospital mortality after iSAVR was identical in 2020 and 2019 (2.8%) and thus higher than after TAVI (p = 0.003), resulting in an observed expected mortality ratio of 1.02 after TAVI and 1.05 after iSAVR. After exclusion of the emergency procedures, in-hospital mortality did not differ significantly between the groups (TAVI 2.2% vs. iSAVR 1.9%, p = 0.26). CONCLUSION: Total numbers of both iSAVR and TAVI in Germany were lower in 2020 than in 2019, most likely due to the COVID-19 pandemic. However, the relative number of patients treated by TAVI as compared to iSAVR continues to increase. Despite older age and more severe comorbidities compared to patients undergoing iSAVR the in-hospital mortality after TAVI continued to decrease in 2020 and remains significantly lower than after iSAVR.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Germany/epidemiology , Heart Valve Prosthesis Implantation/methods , Humans , Pandemics , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
16.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Article in English | MEDLINE | ID: mdl-35138350

ABSTRACT

OBJECTIVES: There are disparities in the adherence to guideline-recommended therapies after coronary artery bypass graft (CABG). We therefore sought to evaluate the effect of guideline-adherent medical secondary prevention on 1-year outcome after CABG. METHODS: Data were taken from the randomized 'Ticagrelor in CABG' trial. From April 2013 until April 2017, patients who underwent CABG were included. For the present analysis, we compared patients who were treated with optimal medical secondary prevention with those where 1 or more of the recommended medications were missing. RESULTS: Follow-up data at 12 months were available in 1807 patients. About half (54%) of them were treated with optimal secondary prevention. All-cause mortality [0.5% vs 3.5%, hazard ratio (HR) 0.14 (0.05-0.37), P < 0.01], cardiovascular mortality [0.1% vs 1.7%, HR 0.06 (0.01-0.46), P = 0.007] and major adverse events [6.5% vs 11.5%, HR 0.54 (0.39-0.74), P < 0.01] were significantly lower in the group with optimal secondary prevention. The multivariable model for the primary end point based on binary concordance to guideline recommended therapy identified 3 independent factors: adherence to guideline recommended therapy [HR 0.55 (0.39-0.78), P < 0.001]; normal renal function [HR 0.99 (0.98-0.99), P = 0.040]; and off-pump surgery [HR 2.06 (1.02-4.18), P = 0.045]. CONCLUSIONS: Only every second patient receives optimal secondary prevention after CABG. Guideline adherent secondary prevention therapy is associated with lower mid-term mortality and less adverse cardiovascular events after 12 months.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Humans , Prognosis , Secondary Prevention , Ticagrelor , Treatment Outcome
17.
Surg Technol Int ; 40: 221-225, 2022 May 19.
Article in English | MEDLINE | ID: mdl-35015897

ABSTRACT

Since the last decade, transcatheter aortic valve implantation (TAVI) has become the treatment of choice in patients with symptomatic severe aortic stenosis (AS) who are ineligible or at higher risk for surgery. Due to the high safety profile of current device generation, TAVI has emerged as a qualified alternative to surgical aortic valve replacement (SAVR) in patients with classic aortic stenosis and intermediate surgical risk, severe bicuspid aortic valve stenosis, and isolated pure aortic regurgitation. Moderate aortic stenosis, with and without concomitant heart failure with reduced ejection fraction, are under investigation in randomized controlled clinical trials from which we will gain exciting insights on the best timing of TAVI to protect the left ventricle from further functional deterioration due to increasing AS. In these cases, a meticulous diagnostic approach including advanced imaging is becoming more and more important. Current evidence on antithrombotic strategies after TAVI is weak, contributing to poor levels of standardization and high variability in daily clinical practice. This review will provide a short overview of recent clinical trials including best timing for TAVI with moderate AS and antithrombotic strategies after TAVI with current and future TAVI generations.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Fibrinolytic Agents , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
18.
Thorac Cardiovasc Surg ; 69(7): 607-613, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34044462

ABSTRACT

BACKGROUND: High-risk patients with multivessel disease (MVD) including a complex stenosis of the left anterior descending coronary may not be ideal candidates for guideline compliant therapy by coronary artery bypass grafting (CABG) regarding invasiveness and perioperative complications. However, they may benefit from minimally invasive direct coronary artery bypass (MIDCAB) grafting and hybrid revascularization (HCR). METHODS: A logistic European system for cardiac operative risk evaluation score (logES) >10% defined high risk. In high-risk patients with MVD undergoing MIDCAB or HCR, the incidence of major adverse cardiac and cerebrovascular events (MACCEs) after 30 days and during midterm follow-up was evaluated. RESULTS: Out of 1,250 patients undergoing MIDCAB at our institution between 1998 and 2015, 78 patients (logES: 18.5%; age, 76.7 ± 8.6 years) met the inclusion criteria. During the first 30 days, mortality and rate of MACCE were 9.0%; early mortality was two-fold overestimated by logES. Complete revascularization as scheduled was finally achieved in 64 patients (82.1%). Median follow-up time reached 3.4 (1.2-6.5) years with a median survival time of 4.7 years. Survival after 1, 3, and 5 years was 77, 62, and 48%. CONCLUSION: In high-risk patients with MVD, MIDCAB is associated with acceptable early outcome which is better than predicted by logES. Taking the high-risk profile into consideration, midterm follow-up showed satisfying results, although scheduled HCR was not realized in a relevant proportion. In selected cases of MVD, MIDCAB presents an acceptable alternative for high-risk patients.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease , Aged , Aged, 80 and over , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Incidence , Minimally Invasive Surgical Procedures , Risk Factors , Treatment Outcome
19.
Clin Res Cardiol ; 110(3): 460-465, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33389039

ABSTRACT

AIMS: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are established options to treat aortic valve stenosis. We present the outcome of the complete cohort of all patients undergoing SAVR or TAVI in Germany during the calendar year 2019. METHODS AND RESULTS: Data concerning all isolated aortic valve procedures performed in Germany in 2019 were retrieved from the mandatory nationwide quality control program: 22,973 transvascular (TV)-TAVI procedures, 7905 isolated SAVR (iSAVR), and 1413 transapical (TA)-TAVI. Data was complete in 99.9% (n = 32,156). In-hospital mortality after TV-TAVI (2.3%) was significantly lower when compared with iSAVR (2.8%, p = 0.007) or TA-TAVI (6.3%; p < 0.001). Expected mortality was calculated with a new version of the German Aortic valve score (AKL Score) based on the data of either catheter-based (AKL-CATH) or surgical (AKL-CHIR) aortic valve replacements in Germany in 2018. TV-TAVI and iSAVR both showed lower observed mortality in 2019 than expected based on their respective performance in 2018, yielding an observed/expected (O/E) mortality ratio < 1. This was particularly apparent for patients at low risk. After exclusion of emergency procedures, in-hospital mortality after TV-TAVI (2.1%) and after iSAVR (2.1%) was identical, even though patients undergoing TV-TAVI showed a considerably higher perioperative risk profile. CONCLUSION: After excluding emergency procedures, in-hospital mortality of TV-TAVI and iSAVR in 2019 in Germany was identical. In 2019, TV-TAVI and iSAVR both show lower matched mortality ratios compared with 2018, which suggests technical improvements of both therapies.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Female , Follow-Up Studies , Germany/epidemiology , Humans , Incidence , Male , Retrospective Studies , Time Factors , Treatment Outcome
20.
J Clin Med ; 11(1)2021 Dec 23.
Article in English | MEDLINE | ID: mdl-35011800

ABSTRACT

OBJECTIVES: The number of transcatheter aortic valve implantations (TAVI) has increased enormously in recent decades. Transcatheter valve prosthesis failure and the requirement of conventional surgical replacement are expected to attract more focus in the near future. Indeed, given the scarcity of research in this field, the next decade will likely represent the beginning of a period of meaningful exploration of the degenerative changes that occur with transcatheter valves. The current study represents-through a series of consecutive cases-one of the first analyses of the underlying causes of TAVI failure, i.e., degenerative, functional and infective, followed by surgical aortic valve replacement (SAVR) and postoperative outcome. METHODS: Between October 2008 and March 2021, 2098 TAVI procedures, including 1423 with transfemoral, 309 with transapical, and 366 with transaortic access, were performed in our institution. Among these, 0.5% (number(n) = 11) required acute SAVR (n = 6) within 7 days (n = 3) or later (n = 2), and were included in the study. RESULTS: Valve stent dislocation was the most common cause of replacement (83%). Causes of replacement within 7 days after TAVI were multifactorial. In the later course, endocarditis was the sole indication for SAVR after TAVI. TAVI with transapical or transaortal approach had a higher EuroSCORE II (10.9 (7.2-35.3) vs. 3.5 (1.8-7.8)). Their 30-day mortality after surgical conversion was higher (67% vs. 20%), when compared to those who underwent a transfemoral procedure. The longest documented survival beyond 30 days was 58 months. CONCLUSIONS: The causes of SAVR after TAVI failure are multifactorial, and include biological, physical and infectious factors. An acceptable midterm prognosis may be expected in patients with physical causes when dislocation of the catheter prosthesis is observed; in such cases, emergency conversion is required. Conversion due to infection, as in cases of endocarditis, had the worst outcome. Prognosis after conversion due to degeneration is still problematic, due to a lack of autopsies and the recent history of prosthetic implantations.

SELECTION OF CITATIONS
SEARCH DETAIL
...