1.
J Biomed Opt ; 15(2): 026028, 2010.
Article in English | MEDLINE | ID: mdl-20459273

ABSTRACT

A high frequency ultrasound-coupled fluorescence tomography system, primarily designed for imaging of protoporphyrin IX production in skin tumors in vivo, is demonstrated for the first time. The design couples fiber-based spectral sampling of the protoporphyrin IX fluorescence emission with high frequency ultrasound imaging, allowing thin-layer fluorescence intensities to be quantified. The system measurements are obtained by serial illumination of four linear source locations, with parallel detection at each of five interspersed detection locations, providing 20 overlapping measures of subsurface fluorescence from both superficial and deep locations in the ultrasound field. Tissue layers are defined from the segmented ultrasound images and diffusion theory used to estimate the fluorescence in these layers. The system calibration is presented with simulation and phantom validation of the system in multilayer regions. Pilot in-vivo data are also presented, showing recovery of subcutaneous tumor tissue values of protoporphyrin IX in a subcutaneous U251 tumor, which has less fluorescence than the skin.


Subject(s)
Protoporphyrins/analysis , Skin Neoplasms/diagnosis , Skin Neoplasms/metabolism , Spectrometry, Fluorescence/instrumentation , Ultrasonography/instrumentation , Equipment Design , Equipment Failure Analysis , Humans , Reproducibility of Results , Sensitivity and Specificity
2.
Rev Sci Instrum ; 80(4): 043701, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19405660

ABSTRACT

A prototype small animal imaging system was created for coupling fluorescence tomography (FT) with x-ray microcomputed tomography (microCT). The FT system has the potential to provide synergistic information content resultant from using microCT images as prior spatial information and then allows overlay of the FT image onto the original microCT image. The FT system was designed to use single photon counting to provide maximal sensitivity measurements in a noncontact geometry. Five parallel detector locations are used, each allowing simultaneous sampling of the fluorescence and transmitted excitation signals through the tissue. The calibration and linearity range performance of the system are outlined in a series of basic performance tests and phantom studies. The ability to image protoporphyrin IX in mouse phantoms was assessed and the system is ready for in vivo use to study biological production of this endogenous marker of tumors. This multimodality imaging system will have a wide range of applications in preclinical cancer research ranging from studies of the tumor microenvironment and treatment efficacy for emerging cancer therapeutics.


Subject(s)
Fluorescence , X-Ray Microtomography/instrumentation , Animals , Calibration , Equipment Design , Humans , Image Processing, Computer-Assisted , Linear Models , Mice , Phantoms, Imaging , Reproducibility of Results , Time Factors