Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chim Acta ; 535: 19-26, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35963304

ABSTRACT

Serotonin is transformed into melatonin under the control of the light/dark cycle, representing a cornerstone of circadian rhythmicity. Serotonin also undergoes extensive metabolism to produce 5-hydroxyindoleacetic acid (5-HIAA), a biomarker for the diagnosis and monitoring of serotonin secreting neuroendocrine tumors (NETs). While serotonin, melatonin and their metabolites are part of an integrated comprehensive system, human observations about their respective plasma concentrations are still limited. We report here for the first time a multiplex UHPLC-MS/MS assay for the quantification of serotonin, 5-HIAA, 5-hydroxytryptophol (5-HTPL), N-acetyl-serotonin (NAS), Mel, 6-OH-Mel, 5-methoxytryptamine (5-MT), 5-methoxytryptophol (5-MTPL), and 5-methoxyindoleacetic acid (5-MIAA) in human plasma. Analytes were extracted by protein precipitation and solid phase extraction. Plasma concentrations for these analytes were determined in 102 healthy volunteers. The LLOQ of the assay ranges from 2.2 nM for serotonin to 1.0 pM for 6-OH-Mel. This sensitivity enables the quantification of circulating serotonin, 5-HIAA, NAS, Mel, and 5-MIAA, even at their lowest diurnal concentrations. This assay will enable specific, precise and accurate measurement of serotonin, Mel and their metabolites to draw a detailed picture of this complex pineal metabolism, allowing a dynamic understanding of these pathways and providing promising biomarkers and a metabolic signature for serotonin-secreting NETs.

2.
J Pharm Biomed Anal ; 124: 48-56, 2016 May 30.
Article in English | MEDLINE | ID: mdl-26928213

ABSTRACT

High-resolution mass spectrometry (HRMS) has been associated with qualitative and research analysis and QQQ-MS with quantitative and routine analysis. This view is now challenged and for this reason, we have evaluated the quantitative LC-MS performance of a new high-resolution mass spectrometer (HRMS), a Q-orbitrap-MS, and compared the results obtained with a recent triple-quadrupole MS (QQQ-MS). High-resolution full-scan (HR-FS) and MS/MS acquisitions have been tested with real plasma extracts or pure standards. Limits of detection, dynamic range, mass accuracy and false positive or false negative detections have been determined or investigated with protease inhibitors, tyrosine kinase inhibitors, steroids and metanephrines. Our quantitative results show that today's available HRMS are reliable and sensitive quantitative instruments and comparable to QQQ-MS quantitative performance. Taking into account their versatility, user-friendliness and robustness, we believe that HRMS should be seen more and more as key instruments in quantitative LC-MS analyses. In this scenario, most targeted LC-HRMS analyses should be performed by HR-FS recording virtually "all" ions. In addition to absolute quantifications, HR-FS will allow the relative quantifications of hundreds of metabolites in plasma revealing individual's metabolome and exposome. This phenotyping of known metabolites should promote HRMS in clinical environment. A few other LC-HRMS analyses should be performed in single-ion-monitoring or MS/MS mode when increased sensitivity and/or detection selectivity will be necessary.


Subject(s)
Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Limit of Detection
3.
Anal Chem ; 88(6): 3264-71, 2016 Mar 15.
Article in English | MEDLINE | ID: mdl-26836506

ABSTRACT

A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

4.
Chimia (Aarau) ; 68(11): 818, 2014 Nov.
Article in English | MEDLINE | ID: mdl-26508491
SELECTION OF CITATIONS
SEARCH DETAIL
...