Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 14957, 2024 06 28.
Article in English | MEDLINE | ID: mdl-38942832

ABSTRACT

The tobacco alkaloid nicotine is known for its activation of neuronal nicotinic acetylcholine receptors. Nicotine is consumed in different ways such as through conventional smoking, e-cigarettes, snuff or nicotine pouches. The use of snuff has been associated with several adverse health effects, such as inflammatory reactions of the oral mucosa and oral cavity cancer. We performed a metabolomic analysis of nicotine-exposed THP-1 human monocytes. Cells were exposed to 5 mM of the alkaloid for up to 4 h, and cell extracts and medium subjected to untargeted liquid chromatography high-resolution mass spectrometry. Raw data processing revealed 17 nicotine biotransformation products. Among these, cotinine and nornicotine were identified as the two major cellular biotransformation products. The application of multi- and univariate statistical analyses resulted in the annotation, up to a certain level of identification, of 12 compounds in the cell extracts and 13 compounds in the medium that were altered by nicotine exposure. Of these, four were verified as methylthioadenosine, cytosine, uric acid, and L-glutamate. Methylthioadenosine levels were affected in both cells and the medium, while cytosine, uric acid, and L-glutamate levels were affected in the medium only. The effects of smoking on the pathways involving these metabolites have been previously demonstrated in humans. Most of the other discriminating compounds, which were merely tentatively or not fully identified, were amino acids or amino acid derivatives. In conclusion, our preliminary data suggest that some of the potentially adverse effects related to smoking may also be expected when nicotine is consumed via snuff or nicotine pouches.


Subject(s)
Mass Spectrometry , Metabolomics , Monocytes , Nicotine , Humans , Nicotine/metabolism , Nicotine/analogs & derivatives , Metabolomics/methods , Monocytes/metabolism , Monocytes/drug effects , Mass Spectrometry/methods , THP-1 Cells , Cotinine/analogs & derivatives , Cotinine/metabolism , Chromatography, Liquid/methods , Metabolome/drug effects , Glutamic Acid/metabolism
2.
Article in English | MEDLINE | ID: mdl-38452631

ABSTRACT

This study aimed to prove the validity of a mixture of chemicals, including salts, small organic molecules, mucin, and α-amylase, as saliva surrogate ("artificial saliva") for assessing leakage of methacrylate monomers and other constituents from dental materials. To achieve this, we developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of 2-hydroxyethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA), diurethane dimethacrylate (UDMA), bisphenol A glycerolate dimethacrylate (BisGMA), diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), bisphenol A (BPA), and five homologues of ethoxylated bisphenol A dimethacrylate (BisEMA EO2-6) in unstimulated and artificial saliva, and compared their concentrations in the two saliva media following either spiking with a mixture of the compounds or incubation of test specimens of printed biomaterials. Test specimens were immersed in unstimulated/artificial saliva, incubated at 37 °C for 24 h, and saliva aliquots were extracted with methanol and subsequently analyzed by LC-MS/MS. The method was validated with regard to matrix effects, linearity, selectivity, lower limits of quantification (LLOQ), precision, bias and combined measurement uncertainty (u'). The performance characteristics of the method were comparable for unstimulated and artificial saliva samples. The combined u' for individual chemicals at a concentration of 10 × LLOQ were within the range of 5.3-14 % for unstimulated saliva and 6.9-16 % for artificial saliva, except for the BisEMA homologues. Combined u' for the latter were 27-74 % in unstimulated saliva, and 27-79 % in artificial saliva. There was no detectable release of BPA from the test specimens, and the TPO concentrations were mainly below the LLOQ. TEGDMA and UDMA were detected in the highest quantities, and at comparable concentrations in the unstimulated and artificial saliva. For all BisEMA homologues, the release was higher in unstimulated saliva than in artificial saliva. The study showed that the artificial saliva model can be a suitable replacement for native saliva, but might underestimate leakage of more lipophilic methacrylates.


Subject(s)
Benzhydryl Compounds , Composite Resins , Phenols , Saliva , Humans , Saliva/chemistry , Chromatography, Liquid , Composite Resins/analysis , Composite Resins/chemistry , Saliva, Artificial/analysis , Tandem Mass Spectrometry , Methacrylates/chemistry , Polymethacrylic Acids/chemistry , Polyethylene Glycols/chemistry , Materials Testing
3.
J Sep Sci ; 36(17): 2838-47, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23813982

ABSTRACT

The single-run resolving power of current 10 µm id porous-layer open-tubular (PLOT) columns has been optimized. The columns studied had a poly(styrene-co-divinylbenzene) porous layer (~0.75 µm thickness). In contrast to many previous studies that have employed complex plumbing or compromising set-ups, SPE-PLOT-LC-MS was assembled without the use of additional hardware/noncommercial parts, additional valves or sample splitting. A comprehensive study of various flow rates, gradient times, and column length combinations was undertaken. Maximum resolution for <400 bar was achieved using a 40 nL/min flow rate, a 400 min gradient and an 8 m long column. We obtained a 2.3-fold increase in peak capacity compared to previous PLOT studies (950 versus previously obtained 400, when using peak width = 2σ definition). Our system also meets or surpasses peak capacities obtained in recent reports using nano-ultra-performance LC conditions or long silica monolith nanocolumns. Nearly 500 proteins (1958 peptides) could be identified in just one single injection of an extract corresponding to 1000 BxPC3 beta catenin (-/-) cells, and ~1200 and 2500 proteins in extracts of 10,000 and 100,000 cells, respectively, allowing detection of central members and regulators of the Wnt signaling pathway.


Subject(s)
Chromatography, Liquid/instrumentation , Proteomics , Tandem Mass Spectrometry/instrumentation , Animals , Humans , Rats