Perfusion ; 16 Suppl: 39-49, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11334205

ABSTRACT

Acute myocardial infarct (MI) results in ischemia distal to lesions which puts heart muscle at risk for reperfusion injury (RI). Neutrophils, platelets and complement are putative mediators of RI. Recent advances in filtration technology provide integrated neutrophil and platelet removal together with complement-attenuating properties in a single blood-conditioning device. The present study characterizes the properties of a blood-conditioning filter and describes its clinical effect when used in conjunction with active hemoperfusion for acute MI. The filter reduces leukocytes by 99.9998 +/- 0.0002% (p<0.0001) and platelets by 99.9934 +/- 0.0069% (p<0.0001). Human plasma, derived from heparinized blood that was 'conditioned' by filtration, was studied using the Langendorff isolated rabbit heart preparation. The deposition of membrane attack complex and the resultant functional myocardial impairments [reflected in hemodynamic and biochemical measurements, including developed pressure, coronary blood flow, lymph-derived myocardial creatine kinase (CK)] are significantly attenuated by blood conditioning. Integration of the blood-conditioning filter into an active hemoperfusion system during primary percutaneous transluminal coronary angioplasty (PTCA) for acute MI (n=8) did not delay the procedure or cause any complications. Reperfusion of occluded coronary arteries with 300 cm3 of conditioned blood led to significant improvement in echocardiographic global wall motion scores (in standard deviations) following treatment (-1.64 +/- 0.18 to -1.45 +/- 0.15, p=0.02). Initial reperfusion of totally occluded coronary arteries with conditioned blood leads to acutely improved ventricular function. Collectively, these data provide a strong indication for continued investigation of conditioned blood reperfusion in angioplasty following acute MI for the long-term effect upon recovery of salvagable myocardium.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Myocardial Infarction/surgery , Reperfusion/methods , Adult , Aged , Aged, 80 and over , Animals , Complement Membrane Attack Complex/metabolism , Complement Membrane Attack Complex/pharmacology , Electrocardiography , Female , Filtration/methods , Humans , In Vitro Techniques , Leukapheresis , Male , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/physiopathology , Pilot Projects , Plateletpheresis , Prospective Studies , Rabbits , Reperfusion Injury/etiology , Reperfusion Injury/prevention & control , Stroke Volume , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...