Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Mech Behav Biomed Mater ; 152: 106437, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38354568

ABSTRACT

The multiscale approach in designing substrates for regenerative medicine endows them with beneficial properties determining their performance in the body. Substrates for corneal regeneration should reveal the proper transparency, mechanical properties and microstructure to maintain the functionality of the regenerated tissue. In our study, series of non-wovens with different fibres orientation (random (R), aligned (A)), topography (shish-kebab (KK), core-shell (CS)) and thickness were fabricated via electrospinning. The samples were assessed for mechanical (static tensile test) and optical properties (spectroscopy UV-Vis). The research evaluated the impact of different microstructures on the viability and morphology of three cell lines (Hs 680, HaCaT and RAW 264.7). The results showed how the fibres arrangement influenced mechanical behaviour of the non-wovens. The randomly oriented fibres were more elongated (up to 50 mm) and had a lower maximum tensile force (up to 0.46 N). In turn, the aligned fibres were characterized by lower elongation (up to 19 mm) and higher force (up to 1.45 N). The conducted transparency tests showed the relation between thickness (of the non-woven and fibres) and morphology of the substrate and light transmission. To simulate the in vivo conditions, prior to the light transmission studies, samples were immersed in water. All the samples exhibited high transparency after immersion in water (>80%). The impact of various morphologies was observed in the in vitro studies. All the samples proved high cells viability. Moreover, the substrate morphology had a significant impact on the orientation and arrangement of the fibroblast cytoskeleton. The aligned fibres were oriented in exactly the same direction. The conducted research proved that, by altering the non-wovens microstructure, the properties can be adjusted so as to induce the desirable cellular reaction. This indicates the high potential of electrospun fibres in terms of modulating the corneal cell behaviour in response to the implanted substrate.


Subject(s)
Cornea , Cytoskeleton , Cell Line , Cell Survival , Water
2.
Materials (Basel) ; 16(7)2023 Mar 23.
Article in English | MEDLINE | ID: mdl-37048837

ABSTRACT

Joining wires made of NiTi alloys with shape memory effect and pseudoelasticity causes many technical and structural problems. They result from unwanted phase interactions that occur in high temperatures and negatively affect the characteristics of these materials. Such obstacles are challenging in terms of welding. Hence, an attempt was made to join NiTi wires via an economical and reliable basic laser welding technique which does not require complicated equipment and gas protection. The parameters such as spot diameter and pulse time were constant and only the laser power, calculated as a percentage of the total power, was optimized. The wires were parallelly connected with overlapping seam welds 10 mm long. The welds were examined regarding their microstructure, chemical and phase composition, reversible martensitic transformation, microhardness, and pseudoelasticity. The obtained results showed that the joint was completed at the 12-14% power. The weld revealed good quality with no voids or pores. As the laser power increased, the microhardness rose from 282 (for 4%) to 321 (for 14%). The joint withstood the stress-inducing reversible martensitic transformation. As the transformation was repeated cyclically, the stress value decreased from 587 MPa (initial wire) to 507 MPa (for the 14% power welded wire).

3.
J Mech Behav Biomed Mater ; 125: 104923, 2022 01.
Article in English | MEDLINE | ID: mdl-34753103

ABSTRACT

In this study, we propose a new approach in the anterior cruciate ligament (ACL) replacement to provide stability and integration with bone tunnel. A polylactide (PLA)-based tubular implant was used to support the graft stabilization in femoral and tibial bones and to stimulate the healing process after (ACL) replacement on a sheep model. The ACL was replaced with an autologous Achilles tendon split graft. The tendon-to-bone healing in the model was analyzed after 6 and 12 weeks. Two groups of animals were compared, i.e. the group with the PLA-based implant used in the ACL replacement and the control group without the implant. The knee joints were mechanically and clinically evaluated, including the histopathology tests, to determine their stability and integrity. The results indicated that the bioresorbable PLA-based tubular implant may facilitate integration of the tendon graft with bone. Remodeling the allograft inside the implant improves the joint mobility from the first week of healing: no pathological changes were observed at the surgery site and in the animals' mobility. After 6 and 12 weeks of healing no significant changes in the mechanical parameters of the knee joint were observed, regarding the joint failure force, knee displacement, angular mobility range and joint stiffness. Relatively small values of the non-destructive tests in the knee displacement, already 6 weeks after surgery, indicated the early stabilization of the knee joint. The studies showed that the failure forces of knee joints after the ACL replacement with the PLA-based implant are lower than those of an intact joint, although their biomechanical features, including strain-at- failure, are similar. The biomechanical parameters of the knee joint were significantly improved due to the selected method of attaching the autograft ends to the femoral and tibial bone surfaces. After 12 weeks the intra-tunnel tendon-bone site with the PLA implant revealed the better tibia-femur joint mechanical stability, linear force-strain function and the decreasing strain-to-failure value, as compared to the control group.


Subject(s)
Achilles Tendon , Anterior Cruciate Ligament , Animals , Anterior Cruciate Ligament/surgery , Autografts , Knee Joint/surgery , Polyesters , Sheep
4.
Materials (Basel) ; 14(22)2021 Nov 16.
Article in English | MEDLINE | ID: mdl-34832307

ABSTRACT

Electrospinning was used to obtain multifunctional fibrous composite materials with a matrix of poly-ɛ-caprolactone (PCL) and 2 wt.% addition of a nanofiller: montmorillonite (MMT), montmorillonite intercalated with gentamicin sulphate (MMTG) or gentamicin sulphate (G). In the first stage, the aluminosilicate gallery was modified by introducing gentamicin sulfate into it, and the effectiveness of the intercalation process was confirmed on the basis of changes in the clay particle size from 0.5 µm (for MMT) to 0.8 µm (for MMTG), an increase in the interplanar distance d001 from 12.3 Å (for MMT) to 13.9 Å (for MMTG) and altered clay grain morphology. In the second part of the experiment, the electrospinning process was carried out in which the polymer nonwovens with and without the modifier were prepared directly from dichloromethane (DCM) and N,N-dimethylformamide (DMF). The nanocomposite fibrous membranes containing montmorillonite were prepared from the same polymer solution but after homogenization with the modifier (13 wt.%). The degree of dispersion of the modifier was evaluated by average microarray analysis from observed area (EDS), which was also used to determine the intercalation of montmorillonite with gentamicin sulfate. An increase in the size of the fibers was found for the materials with the presence of the modifier, with the largest diameters measured for PCL_MMT (625 nm), and the smaller ones for PCL_MMTG (578 nm) and PCL_G (512 nm). The dispersion of MMT and MMTG in the PCL fibers was also confirmed by indirect studies such as change in mechanical properties of the nonwovens membrane, where the neat PCL nonwoven was used as a reference material. The addition of the modifier reduced the contact angle of PCL nonwovens (from 120° for PCL to 96° for PCL_G and 98° for PCL_MMTG). An approximately 10% increase in tensile strength of the nonwoven fabric with the addition of MMT compared to the neat PCL nonwoven fabric was also observed. The results of microbiological tests showed antibacterial activity of all obtained materials; however, the inhibition zones were the highest for the materials containing gentamicin sulphate, and the release time of the active substance was significantly extended for the materials with the addition of montmorillonite containing the antibiotic. The results clearly show that the electrospinning technique can be effectively used to obtain nanobiocomposite fibers with the addition of nonintercalated and intercalated montmorillonite with improved strength and increased stiffness compared to materials made only of the polymer fibers, provided that a high filler dispersion in the spinning solution is obtained.

5.
Acta Biomater ; 2(4): 457-66, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16723287

ABSTRACT

beta-Tricalcium phosphate (beta-TCP) scaffolds with designed, three-dimensional (3-D) geometry and mesoscale porosity have been fabricated by direct-write assembly (robocasting) techniques. Concentrated beta-TCP inks with suitable viscoelastic properties were developed to enable the fabrication of the complex 3-D structures. A comprehensive study of the sintering behavior of TCP as a function of the calcium content in the starting powder was also carried out, and the optimal heat treatment for fabricating scaffolds with dense beta-TCP rods has been determined. Such analysis provides clues to controlling the microstructure of the fabricated structures and, therefore, enabling the fabrication by robocasting of TCP scaffolds with tailored performance for bone tissue engineering applications.


Subject(s)
Biocompatible Materials/chemistry , Biomedical Engineering , Bone Substitutes/chemistry , Calcium Phosphates/chemistry , Chemistry, Bioinorganic/methods , Manufactured Materials , Microscopy, Electron, Scanning , Porosity , Powders/chemistry , Viscosity
SELECTION OF CITATIONS
SEARCH DETAIL
...