Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Dev Dis ; 10(2)2023 Jan 30.
Article in English | MEDLINE | ID: mdl-36826552

ABSTRACT

The non-thermal effects are considered one of the prominent advantages of pulsed field ablation (PFA). However, at higher PFA doses, the temperature rise in the tissue during PFA may exceed the thermal damage threshold, at which time intracardiac pulsatile blood flow plays a crucial role in suppressing this temperature rise. This study aims to compare the effect of heat dissipation of the different methods in simulating the pulsatile blood flow during PFA. This study first constructed an anatomy-based left atrium (LA) model and then applied the convective heat transfer (CHT) method and the computational fluid dynamics (CFD) method to the model, respectively, and the thermal convective coefficients used in the CHT method are 984 (W/m2*K) (blood-myocardium interface) and 4372 (W/m2*K) (blood-catheter interface), respectively. Then, it compared the effect of the above two methods on the maximum temperature of myocardium and blood, as well as the myocardial ablation volumes caused by irreversible electroporation (IRE) and hyperthermia under different PFA parameters. Compared with the CFD method, the CHT method underestimates the maximum temperature of myocardium and blood; the differences in the maximum temperature of myocardium and blood between the two methods at the end of the last pulse are significant (>1 °C), and the differences in the maximum temperature of blood at the end of the last pulse interval are significant (>1 °C) only at a pulse amplitude greater than 1000 V or pulse number greater than 10. Under the same pulse amplitude and different heat dissipation methods, the IRE ablation volumes are the same. Compared with the CFD method, the CHT method underestimates the hyperthermia ablation volume; the differences in the hyperthermia ablation volume are significant (>1 mm3) only at a pulse amplitude greater than 1000 V, a pulse interval of 250 ms, or a pulse number greater than 10. Additionally, the hyperthermia ablation isosurfaces are completely wrapped by the IRE ablation isosurfaces in the myocardium. Thus, during PFA, compared with the CFD method, the CHT method cannot accurately simulate the maximum myocardial temperature; however, except at the above PFA parameters, the CHT method can accurately simulate the maximum blood temperature and the myocardial ablation volume caused by IRE and hyperthermia. Additionally, within the range of the PFA parameters used in this study, the temperature rise during PFA may not lead to the appearance of additional hyperthermia ablation areas beyond the IRE ablation area in the myocardium.

2.
J Cardiovasc Dev Dis ; 9(10)2022 Sep 22.
Article in English | MEDLINE | ID: mdl-36286271

ABSTRACT

Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF); however, the effect of fiber orientation on the ablation characteristics of PFA in AF treatment is still unclear, which is likely an essential factor in influencing the ablation characteristics. This study constructed an anatomy-based left atrium (LA) model incorporating fiber orientation and selected various electrical conductivity and ablation targets to investigate the effect of anisotropic electrical conductivity (AC), compared with isotropic electrical conductivity (IC), on the ablation characteristics of PFA in AF treatment. The results show that the percentage differences in the size of the surface ablation area between AC and IC are greater than 73.71%; the maximum difference in the size of the ablation isosurface between AC and IC at different locations in the atrial wall is 3.65 mm (X-axis), 3.65 mm (Z-axis), and 4.03 mm (X-axis), respectively; and the percentage differences in the size of the ablation volume are greater than 6.9%. Under the condition of the pulse, the amplitude is 1000 V, the total PFA duration is 1 s, and the pulse train interval is 198.4 ms; the differences in the temperature increase between AC and IC in LA are less than 2.46 °C. Hence, this study suggests that in further exploration of the computational study of PFA in AF treatment using the same or similar conditions as those used here (myocardial electrical conductivity, pulse parameters, and electric field intensity damage threshold), to obtain more accurate computational results, it is necessary to adopt AC rather than IC to investigate the size of the surface ablation area, the size of the ablation isosurface, or the size of the ablation volume generated by PFA in LA. Moreover, if only investigating the temperature increase generated by PFA in LA, adopting IC instead of AC for simplifying the model construction process is reasonable.

3.
Int J Hyperthermia ; 39(1): 1064-1077, 2022.
Article in English | MEDLINE | ID: mdl-35993225

ABSTRACT

BACKGROUND: Highly consistent cardiac ablation outcomes through radiofrequency catheter ablation (RFCA) under pulsatile and constant flow profiles (PP&CP) of intracardiac blood were previously indicated by computer modeling, with simplified geometry and lossless receipt of inflow for ablation catheters. This study aimed to further investigate the effects of intracardiac blood pulsatility in an anatomy-based atrium model. METHODS: Four pulmonary veins were blood inflows at 10 mm Hg. The mitral valve was the outflow, with PP based on pulsatile velocity curve from clinical measurements, and CP was obtained by averaging the velocity curve under PP over an ablation time of 30 s. A numerical comparison between ablation results under PP and CP, without experimental validation, was performed. RESULTS: Temperature fluctuations persisted in mid-myocardium, and most clearly in blood and endocardium under PP. At a constant power of 20 W, marked differences in ablation outcome between PP and CP occurred in the middle of unilateral pulmonary veins and the posterior wall of the left atrium (LA) where the blood velocities were significantly decreased under CP. The mid-myocardial, blood and endocardial temperatures, as well as the effective lesion volume at the former position, were decreased by 4.1%, 15%, 13.6%, and 13.8%, respectively under PP. The extents for the latter position were 11%, 22%, 22.5%, and 55.6%, respectively. CONCLUSION: Intracardiac flow pulsatility causes a greater reduction in blood and endocardial temperatures at ablation sites away from the main bloodstream, effective cooling of which is more likely to rely on blood velocities approaching peak PP values.


Subject(s)
Catheter Ablation , Pulmonary Veins , Blood Flow Velocity/physiology , Catheter Ablation/methods , Heart Atria/surgery , Pulmonary Veins/surgery , Temperature
4.
Int J Hyperthermia ; 39(1): 120-133, 2022.
Article in English | MEDLINE | ID: mdl-35000495

ABSTRACT

BACKGROUND: Traditional computer simulation studies of radiofrequency catheter ablation (RFCA) usually neglect the anisotropy in myocardial electrical conductivity (MEC), which is likely an essential factor in governing the ablation outcome. Here, a numerical study of lesion characteristics during RFCA based on an anatomy-based model incorporating fiber orientation was performed to investigate the anisotropy in MEC. METHODS: A three-dimensional thorax model including atria, blood, connective tissue, muscle, fat, and skin was constructed. The myocardial fiber was established through a rule-based method (RBM) based on the anatomical structure of the heart. The anisotropic MEC were 0.40 and 0.28 S m-1 in longitudinal and transverse directions, respectively. The ablation result was compared with the isotropic scenario where the isotropic MEC was the average of the anisotropic conductivities as 0.34 S m-1. RESULTS: The complexity of fiber architecture varied with that of the local anatomical structure. At RF power of 20 W for 30 s, the tissue temperature and lesion volume were reduced by 2.8 ± 0.1% and 6.9 ± 0.5%, respectively, under anisotropic MEC around the ostium of the pulmonary vein and left atrial appendage. Those for the posterior wall and roof of the left atrium, and the inside of the superior vena cava were 1.9 ± 0.3% and 5.6 ± 1.2%, respectively. CONCLUSIONS: Anisotropy in MEC has a greater reduction effect on lesion volume than on tissue temperature during RFCA; this effect tends to be restrained at positions with more uniform fiber distributions and can be enhanced where significant variation in fiber architecture occurred.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Anisotropy , Atrial Fibrillation/surgery , Catheter Ablation/methods , Computer Simulation , Electric Conductivity , Humans , Vena Cava, Superior/surgery
5.
Int J Hyperthermia ; 37(1): 37-48, 2020.
Article in English | MEDLINE | ID: mdl-31918588

ABSTRACT

Purpose: In cardiac radiofrequency (RF) ablation, RF energy is often used to create a series of transmural lesions for blocking accessory conduction pathways. Electrode-tissue contact force (CF) is one of the key determinants of lesion formation during RF ablation. Low electrode-tissue CF is associated with ineffective RF lesion formation, whereas excessive CF may increase the risk of steam pop and perforation. By using finite element analysis, we studied lesion size and features at different values of electrode-tissue CF in cardiac RF ablation.Materials and methods: A computer-model-coupled electrode-tissue CF field, RF electric field, and thermal field were developed to study temperature distribution and lesion dimensions in cardiac tissue subjected to CF of 2, 5, 10, 20, 30, and 40 g with identical RF voltage and duration.Results: Increasing CF was associated with an increase in lesion depth, width, and cross-section area. The lesion cross-section area exhibited a linear increase, and the lesion width was significantly greater than lesion depth under the identical ablation condition. The relationship between CF value and lesion size is a power function: Lesion Size = a × CFb (Lesion Depth = 3.17 × CF0.14 and Lesion Width = 5.17 × CF0.14).Conclusions: This study confirmed that CF is a major determinant of RF lesion size and that electrode-tissue CF affects the amount of power dissipated in tissue. At a constant RF voltage and application time, RF lesion size increases as CF increases.


Subject(s)
Computer Simulation/standards , Electrodes/standards , Heart/radiation effects , Radiofrequency Ablation/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...