1.
Health Phys ; 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38683685

ABSTRACT

ABSTRACT: Boron neutron capture therapy (BNCT) is an ideal binary targeted radiotherapy for treating refractory tumors. An accelerator-based BNCT (AB-BNCT) neutron source has attracted more and more attention due to its advantages such as higher neutron yield in the keV energy region, less gamma radiation, and higher safety. In addition to 10B, neutrons also react with other elements in the treatment room during BNCT to produce many activation products. Due to the long half-life of some activation products, there will be residual radiation after the end of treatment and the shutdown of the accelerator, which has adverse effects on radiation workers. Therefore, the ambient dose equivalent rate in the treatment room needs to be evaluated. The AB-BNCT neutron source model proposed by Li is studied in this paper. Based on the Monte Carlo method, the Geant4 platform was used to simulate the dose induced by radionuclides near the Beam Shaping Assembly (BSA) of the source. It is concluded that the concrete wall contributed the most to the radiation dose. The dose rate of 2.45 µSv h-1 after 13 min of shutdown meets the dose rate limit of 2.5 µSv h-1, at which point it is safe for workers to enter the treatment room area.

2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(1): 133-140, 2023 Feb 25.
Article in Chinese | MEDLINE | ID: mdl-36854558

ABSTRACT

To investigate the γ pass rate limit of plan verification equipment for volumetric modulated arc therapy (VMAT) plan verification and its sensitivity on the opening and closing errors of multi-leaf collimator (MLC), 50 cases of nasopharyngeal carcinoma VMAT plan with clockwise and counterclockwise full arcs were randomly selected. Eight kinds of MLC opening and closing errors were introduced in 10 cases of them, and 80 plans with errors were generated. Firstly, the plan verification was conducted in the form of field-by-field measurement and true composite measurement. The γ analysis with the criteria of 3% dose difference, distance to agreement of 2 mm, 10% dose threshold, and absolute dose global normalized conditions were performed for these fields. Then gradient analysis was used to investigate the sensitivity of field-by-field measurement and true composite measurement on MLC opening and closing errors, and the receiver operating characteristic curve (ROC) was used to investigate the optimal threshold of γ pass rate for identifying errors. Tolerance limits and action limits for γ pass rates were calculated using statistical process control (SPC) method for another 40 cases. The error identification ability using the tolerance limit calculated by SPC method and the universal tolerance limit (95%) were compared with using the optimal threshold of ROC. The results show that for the true composite measurement, the clockwise arc and the counterclockwise arc, the descent gradients of the γ passing rate with per millimeter MLC opening error are 10.61%, 7.62% and 6.66%, respectively, and the descent gradients with per millimeter MLC closing error are 9.75%, 7.36% and 6.37%, respectively. The optimal thresholds obtained by the ROC method are 99.35%, 97.95% and 98.25%, respectively, and the tolerance limits obtained by the SPC method are 98.98%, 97.74% and 98.62%, respectively. The tolerance limit calculated by SPC method is close to the optimal threshold of ROC, both of which could identify all errors of ±2 mm, while the universal tolerance limit can only partially identify them, indicating that the universal tolerance limit is not sensitive on some large errors. Therefore, considering the factors such as ease of use and accuracy, it is suggested to use the true composite measurement in clinical practice, and to formulate tolerance limits and action limits suitable for the actual process of the institution based on the SPC method. In conclusion, it is expected that the results of this study can provide some references for institutions to optimize the radiotherapy plan verification process, set appropriate pass rate limit, and promote the standardization of plan verification.


Subject(s)
Nasopharyngeal Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Immune Tolerance , Nasopharyngeal Carcinoma , ROC Curve , Nasopharyngeal Neoplasms/radiotherapy
3.
Technol Cancer Res Treat ; 21: 15330338221114499, 2022.
Article in English | MEDLINE | ID: mdl-36112945

ABSTRACT

Purpose: To compare the sensitivity of ArcCHECK (AC), portal dosimetry (PD), and an in-house logfile-based system (LF) to multileaf collimators (MLC) aperture errors and the ability to identify these errors. Methods and Materials: For 12 retrospective original head and neck volumetric modulated arc therapy (VMAT) plans, MLC aperture errors of ± 0.4mm, ± 1.2mm, ± 2mm, and ± 3mm were introduced for each plan, resulting in 96 plans with errors. AC, PD, and LF were used for the gamma evaluation at 3%/3mm, 3%/2mm, and 2%/2mm criteria. Gradient analysis was used to evaluate the sensitivity to MLC aperture errors. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve was used to evaluate the ability to identify MLC aperture errors and dose errors, and the optimal cut-off value to identify the error was obtained. Results: The gamma pass rate (%GP) of LF had the smallest descent gradient as the MLC error increases in any case. The descent gradient of PD was larger than AC, except for the case at the 2%/2mm criteria. For the 3%/3mm criteria, the MLC aperture errors that can be perfectly identified by AC, PD, and LF were ± 3mm, ± 2mm, and ± 1.2mm, respectively, and the average percent dose error (%DEs) of dose metrics in targets that can be perfectly identified were 4% to 5%, 3% to 4%, and 2% to 3%, respectively. For the 3%/2mm criteria, the errors that AC, PD, and LF can perfectly identify were the same as the 3%/3mm criteria. For the 2%/2mm criteria, AC can perfectly identify the MLC error of ± 2mm and the %DE of 3% to 4%. PD and LF can identify the MLC error of ± 1.2mm and the %DE of 2% to 3%. Conclusion: Different patient-specific quality assurance (PSQA) systems have different sensitivity and recognition abilities to MLC aperture errors. Institutions should formulate their own customized %GP limits based on their PSQA process through ROC or other methods.


Subject(s)
Radiotherapy, Intensity-Modulated , Gamma Rays , Humans , Radiometry , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies