1.
MAGMA ; 36(6): 933-943, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37566311

ABSTRACT

OBJECTIVE: To enhance RF safety when implantable medical devices are located within the body coil but outside the imaging region by using a secondary resonator (SR) to reduce electric fields, the corresponding specific absorption rate (SAR), and temperature change during MRI. MATERIALS AND METHODS: This study was conducted using numerical simulations with an American Society for Testing and Materials (ASTM) phantom and adult human models of Ella and Duke from Virtual Family Models, along with corresponding experimental results of temperature change obtained using the ASTM phantom. The circular SR was designed with an inner diameter of 150 mm and a width of 6 mm. Experimental measurements were carried out using a 3 T Medical Implant Test System (MITS) body coil, electromagnetic (EM) field mapping probes, and an ASTM phantom. RESULTS: The magnitudes of B1+ (|B1+|) and SAR1g were reduced by 15.2% and 5.85% within the volume of interest (VoI) of an ASTM phantom, when a SR that generates opposing electromagnetic fields was utilized. Likewise, the Δ|B1+| and ΔSAR1g were reduced by up to 56.7% and 57.5% within the VoI of an Ella model containing a copper rod when an opposing SR was used. CONCLUSION: A novel method employing the designed SR, which generates opposing magnetic fields to partially shield a sample, has been proposed to mitigate the risk of induced-RF heating at the VoI through numerical simulations and corresponding experiments under various conditions at 3.0 T.


Subject(s)
Electromagnetic Fields , Prostheses and Implants , Humans , Magnetic Fields , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Radio Waves
2.
Magn Reson Med ; 87(3): 1515-1528, 2022 03.
Article in English | MEDLINE | ID: mdl-34775615

ABSTRACT

PURPOSE: There is increasing use of open-bore vertical MR systems that consist of two planar RF coils. A recent study showed that the RF-induced heating of a neuromodulation device was much lower in the open-bore system at the brain and the chest imaging landmarks. This study focused on the hip and knee implants and compared the specific absorption rate (SAR) distribution in human models in a 1.2T open-bore coil with that of a 1.5T conventional birdcage coil. METHODS: Computational modeling results were compared against the measurement values using a saline phantom. The differences in RF exposure were examined between a 1.2T open-bore coil and a 1.5T conventional birdcage coil using SAR in an anatomical human model. RESULTS: Modeling setups were validated. The body placed closed to the coil elements led to high SAR values in the birdcage system compared with the open-bore system. CONCLUSION: Our computational modeling showed that the 1.2T planar system demonstrated a lower intensity of SAR distribution adjacent to hip and knee implants compared with the 1.5T conventional birdcage system.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Heating , Humans , Phantoms, Imaging , Prostheses and Implants
3.
IEEE Electromagn Compat Mag ; 11(3): 49-54, 2022 Dec 12.
Article in English | MEDLINE | ID: mdl-36699954

ABSTRACT

It has been shown that the presence of a hand holding a wireless handset (cell phone) can influence antenna efficiency and the measurement of specific absorption rate (SAR) and electromagnetic compatibility. Head phantoms, used in handset compliance testing to estimate SAR in the head, have achieved low cost and multi-frequency use. Head phantoms typically consist of a thin plastic shell, open on the top, holding a tissue simulating fluid. The specific simulant fluid used is determined by the radio frequency of the test. IEC 62209-1 has recipes, using safe nontoxic materials, for all the required frequency bands. Thus, head phantoms can be reused at different frequencies simply by changing the tissue simulating fluid. However, standards have not adopted the use of hand phantoms because SAR limits in limbs are less restrictive than the head, the tissue depth in a hand is insufficient to make accurate measurements with current electric field probes, and the cost of a solid hand phantom is limited to a single frequency band. Our goal was to determine whether 3D printing techniques would allow the construction of a hand phantom with the same utility as existing head phantoms. We developed this phantom based on computer simulations to determine how much human anatomy needed to be included in the phantom to obtain results consistent with actual use. Electric field scans of a handset alone, and held by the hand phantom, were performed. Comparison of handset scans using the phantom and human subjects was planned, but not performed due to Covid-19 restrictions and subsequent changes in priorities. We feel a fluid-filled 3D printed hand phantom is viable and practical. The 3D print files are available on GitHub.

4.
IEEE Trans Biomed Eng ; 62(4): 1063-9, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25347873

ABSTRACT

Materials with high dielectric constant (HDC) have been used in high field MRI to decrease specific absorption rate (SAR), increase magnetic field intensity, and increase signal-to-noise ratio. In previous studies, the HDC materials were placed inside the RF coil decreasing the space available. This study describes an alternative approach that considers an HDC-based sleeve placed outside the RF coil. The effects of an HDC on the electromagnetic (EM) field were studied using numerical simulations with a coil unloaded and loaded with a human head model. In addition, experimental EM measurements at 128 MHz were performed inside a custom-made head coil, fitted with a distilled water sleeve. The numerical simulations showed up to 40% decrease in maximum 10 g-avg. SAR on the surface of the head model with an HDC material of barium titanate. Experimental measurements also showed up to 20% decrease of maximum electric field using an HDC material of distilled water. The proposed method can be incorporated in the design of high field transmit RF coils.


Subject(s)
Electromagnetic Fields , Head/physiology , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Barium Compounds , Computer Simulation , Humans , Image Processing, Computer-Assisted , Signal-To-Noise Ratio , Titanium
5.
Biomed Eng Online ; 12: 71, 2013 Jul 11.
Article in English | MEDLINE | ID: mdl-23845013

ABSTRACT

BACKGROUND: The use of radiofrequency identification (RFID) in healthcare is increasing and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have documented that RFID can interfere with medical devices. The majority of past studies have concentrated on implantable medical devices such as implantable pacemakers and implantable cardioverter defibrillators (ICDs). This study examined EMC between RFID systems and non-implantable medical devices. METHODS: Medical devices were exposed to 19 different RFID readers and one RFID active tag. The RFID systems used covered 5 different frequency bands: 125-134 kHz (low frequency (LF)); 13.56 MHz (high frequency (HF)); 433 MHz; 915 MHz (ultra high frequency (UHF])) and 2.4 GHz. We tested three syringe pumps, three infusion pumps, four automatic external defibrillators (AEDs), and one ventilator. The testing procedure is modified from American National Standards Institute (ANSI) C63.18, Recommended Practice for an On-Site, Ad Hoc Test Method for Estimating Radiated Electromagnetic Immunity of Medical Devices to Specific Radio-Frequency Transmitters. RESULTS: For syringe pumps, we observed electromagnetic interference (EMI) during 13 of 60 experiments (22%) at a maximum distance of 59 cm. For infusion pumps, we observed EMI during 10 of 60 experiments (17%) at a maximum distance of 136 cm. For AEDs, we observed EMI during 18 of 75 experiments (24%) at a maximum distance of 51 cm. The majority of the EMI observed was classified as probably clinically significant or left the device inoperable. No EMI was observed for all medical devices tested during exposure to 433 MHz (two readers, one active tag) or 2.4 GHz RFID (two readers). CONCLUSION: Testing confirms that RFID has the ability to interfere with critical medical equipment. Hospital staff should be aware of the potential for medical device EMI caused by RFID systems and should be encouraged to perform on-site RF immunity tests prior to RFID system deployment or prior to placing new medical devices in an RFID environment. The methods presented in this paper are time-consuming and burdensome and suggest the need for standard test methods for assessing the immunity of medical devices to RFID systems.


Subject(s)
Defibrillators , Electromagnetic Phenomena , Infusion Pumps , Radio Frequency Identification Device , Radio Waves , Syringes , Ventilators, Mechanical , Equipment Safety
6.
Biomed Eng Online ; 10: 94, 2011 Oct 21.
Article in English | MEDLINE | ID: mdl-22014169

ABSTRACT

BACKGROUND: Over the last decade, the number of neurostimulator systems implanted in patients has been rapidly growing. Nearly 50, 000 neurostimulators are implanted worldwide annually. The most common type of implantable neurostimulators is indicated for pain relief. At the same time, commercial use of other electromagnetic technologies is expanding, making electromagnetic interference (EMI) of neurostimulator function an issue of concern. Typically reported sources of neurostimulator EMI include security systems, metal detectors and wireless equipment. When near such sources, patients with implanted neurostimulators have reported adverse events such as shock, pain, and increased stimulation. In recent in vitro studies, radio frequency identification (RFID) technology has been shown to inhibit the stimulation pulse of an implantable neurostimulator system during low frequency exposure at close distances. This could potentially be due to induced electrical currents inside the implantable neurostimulator leads that are caused by magnetic field coupling from the low frequency identification system. METHODS: To systematically address the concerns posed by EMI, we developed a test platform to assess the interference from coupled magnetic fields on implantable neurostimulator systems. To measure interference, we recorded the output of one implantable neurostimulator, programmed for best therapy threshold settings, when in close proximity to an operating low frequency RFID emitter. The output contained electrical potentials from the neurostimulator system and those induced by EMI from the RFID emitter. We also recorded the output of the same neurostimulator system programmed for best therapy threshold settings without RFID interference. Using the Spatially Extended Nonlinear Node (SENN) model, we compared threshold factors of spinal cord fiber excitation for both recorded outputs. RESULTS: The electric current induced by low frequency RFID emitter was not significant to have a noticeable effect on electrical stimulation. CONCLUSIONS: We demonstrated a method for analyzing effects of coupled magnetic field interference on implantable neurostimulator system and its electrodes which could be used by device manufacturers during the design and testing phases of the development process.


Subject(s)
Electric Stimulation Therapy/instrumentation , Electromagnetic Phenomena , Implantable Neurostimulators , Magnetic Fields , Radio Frequency Identification Device/methods , Equipment Safety , Humans , Radio Frequency Identification Device/standards
7.
Biomed Eng Online ; 10: 50, 2011 Jun 09.
Article in English | MEDLINE | ID: mdl-21658266

ABSTRACT

BACKGROUND: The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. METHODS: Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. RESULTS: The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. CONCLUSIONS: The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.


Subject(s)
Electromagnetic Phenomena , Implantable Neurostimulators , Radio Frequency Identification Device/methods , Electric Stimulation Therapy/instrumentation , Electromagnetic Fields , Humans , Radio Frequency Identification Device/standards , United States , United States Food and Drug Administration
8.
Phys Med Biol ; 55(2): N23-38, 2010 Jan 21.
Article in English | MEDLINE | ID: mdl-20019402

ABSTRACT

The objective of this study was to develop anatomically correct whole body human models of an adult male (34 years old), an adult female (26 years old) and two children (an 11-year-old girl and a six-year-old boy) for the optimized evaluation of electromagnetic exposure. These four models are referred to as the Virtual Family. They are based on high resolution magnetic resonance (MR) images of healthy volunteers. More than 80 different tissue types were distinguished during the segmentation. To improve the accuracy and the effectiveness of the segmentation, a novel semi-automated tool was used to analyze and segment the data. All tissues and organs were reconstructed as three-dimensional (3D) unstructured triangulated surface objects, yielding high precision images of individual features of the body. This greatly enhances the meshing flexibility and the accuracy with respect to thin tissue layers and small organs in comparison with the traditional voxel-based representation of anatomical models. Conformal computational techniques were also applied. The techniques and tools developed in this study can be used to more effectively develop future models and further improve the accuracy of the models for various applications. For research purposes, the four models are provided for free to the scientific community.


Subject(s)
Computer Simulation , Models, Anatomic , Radiometry/methods , Access to Information , Adult , Automation , Child , Elasticity , Electromagnetic Fields , Family , Female , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male