Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Luminescence ; 21(2): 81-9, 2006.
Article in English | MEDLINE | ID: mdl-16416484

ABSTRACT

Cathodic electrochemiluminescence (ECL) behaviours of the acetonitrile, acetonitrile-1,10-phenanthroline (phen) and acetonitrile-ternary Eu(III) complex systems at a gold electrode were studied. One very weak cathodic ECL-2 at -3.5 V was observed in 0.1 mol/L tetrabutylammonium tetrafluoroborate (TBABF(4)) acetonitrile solution. When 10 mmol/L tetrabutylammonium peroxydisulphate [(TBA)(2)S(2)O(8)] was added to 0.1 mol/L TBABF(4) acetonitrile solution, another cathodic ECL-1 at -2.7 V appeared and the potential for ECL-2 was shifted from -3.5 to -3.1 V. Furthermore, ECL-2 intensity was enhanced about 20-fold. When 1 x 10(-4) mol/L phen was added to 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution, the ECL intensities of ECL-1 and ECL-2 were enhanced about 20-fold compared with those of 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution. The maximum emission peaks of ECL-1 and ECL-2 in the three systems mentioned above appeared at about 530 nm. The products obtained by electrolysing 0.1 mol/L TBABF(4) acetonitrile solution at -3.5 V for 20 min were analysed by Fourier Transform Infrared (FTIR) spectra and gas chromatography-mass spectrometry (GC-MS) and the emitter of ECL-1 and ECL-2 was identified as excited state polyacetonitrile. When ternary Eu(III) complexes were presented in 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution, another maximum emission peak with a narrow band centred at about 610 nm appeared in ECL-1 in addition to the maximum emission peaks at about 530 nm for ECL-1 and ECL-2. The emitter of ECL emission at 610 nm was identified as the excited states Eu(III)*. The mechanisms for cathodic ECL behaviours of the acetonitrile, acetonitrile-phen and acetonitrile-ternary Eu(III) complex systems at a gold electrode have been proposed. The extremely sharp emission bands for ternary Eu(III) complexes may have analytical potential.


Subject(s)
Acetonitriles/chemistry , Europium/chemistry , Gold/chemistry , Luminescence , Luminescent Measurements/methods , Organometallic Compounds/chemistry , Phenanthrolines/chemistry , Electrochemistry/methods , Electrodes , Free Radicals/chemistry , Molecular Structure , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...