1.
Front Surg ; 11: 1418679, 2024.
Article in English | MEDLINE | ID: mdl-38983589

ABSTRACT

Objective: The development of surgical microscope-associated cameras has given rise to a new operating style embodied by hybrid microsurgical and exoscopic operative systems. These platforms utilize specialized camera systems to visualize cranial neuroanatomy at various depths. Our study aims to understand how different camera settings in a novel hybrid exoscope system influence image quality in the context of neurosurgical procedures. Methods: We built an image database using captured cadaveric dissection images obtained with a prototype version of a hybrid (microsurgical/exoscopic) operative platform. We performed comprehensive 4K-resolution image capture using 76 camera settings across three magnification levels and two working distances. Computer algorithms such as structural similarity (SSIM) and mean squared error (MSE) were used to measure image distortion across different camera settings. We utilized a Laplacian filter to compute the overall sharpness of the acquired images. Additionally, a monocular depth estimation deep learning model was used to examine the image's capability to visualize the depth of deeper structures accurately. Results: A total of 1,368 high-resolution pictures were captured. The SSIM index ranged from 0.63 to 0.85. The MSE was nearly zero for all image batches. It was determined that the exoscope could accurately detect both the sharpness and depth based on the Laplacian filter and depth maps, respectively. Our findings demonstrate that users can utilize the full range of camera settings available on the exoscope, including adjustments to aperture, color saturation, contrast, sharpness, and brilliance, without introducing significant image distortions relative to the standard mode. Conclusion: The evolution of the camera incorporated into a surgical microscope enables exoscopic visualization during cranial base surgery. Our result should encourage surgeons to take full advantage of the exoscope's extensive range of camera settings to match their personal preferences or specific clinical requirements of the surgical scenario. This places the exoscope as an invaluable asset in contemporary surgical practice, merging high-definition imaging with ergonomic design and adaptable operability.

3.
Front Surg ; 6: 41, 2019.
Article in English | MEDLINE | ID: mdl-31380388

ABSTRACT

5-Aminolevulinic acid (5-ALA) induced fluorescence to augment surgical resection for high grade glioma has become a standard of care. Protoporphyrin IX (PpIX) visibility is however subject to the variability of the single tumor expression and to the interobserver interpretation. We therefore hypothesized that in different glioma cell lines with variable 5-ALA induced fluorescence, the signal can be pharmacologically increased. We therefore analyzed in three different GBM cell lines, with different expression of epidermal growth factor receptor (EGFR), the variability of 5-ALA induced PpIX fluorescence after the pharmacological blockade at different steps of PpIX breakdown and influencing the outbound transport of PpIX. Using flow cytometry, fluorescence microplate reader, and confocal microscopy the PpIX fluorescence was analyzed after exposure to tin protoporphyrin IX (SnPP), deferoxamine (DFO), and genistein. We furthermore constructed a microscope (Qp9-microscope) being able to measure quantitatively the concentration of PpIX. These values were compared with the extraction of PpIX in tumor biopsy taken during the GBM surgery. Although all three cell lines showed an increase to 5-ALA induced fluorescence their baseline activity was different. Treatment with either SnPP, DFO and genistein was able to increase 5-ALA induced fluorescence. Qp9-microscopy of tumor sample produced a color coded PpIX concentration map which was overlaid on the tumor image. The PpIX extraction from tumor sample analyzed using the plate reader gave lower values of the concentration, as compared to the expected values of the Qp9-microscope, however still in the same decimal range of µg/mL. This may be due to homogenization of the values during extraction and cell disaggregation. In conclusion pharmacological augmentation in GBM cell lines of PpIX signal is possible. A quantitative PpIX map for surgery is feasible and may help refine surgical excision. Further correlations of tumor tissue samples and Qp9-microscopy is needed, prior to develop an intraoperative surgical adjunct to the already existing 5-ALA induced surgery.

4.
Acta Neurochir (Wien) ; 153(11): 2181-7, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21894496

ABSTRACT

In cerebral arterioveneous malformations (AVMs) detailed intraoperative identification of feeding arteries, nidal vessels and draining veins is crucial for surgery. Intraoperative imaging techniques like indocyanine green videoangiography (ICG-VAG) provide information about vessel architecture and patency, but do not allow time-dependent analysis of intravascular blood flow. Here we report on our first experiences with analytical indocyanine green videoangiography (aICG-VAG) using FLOW 800 software as a useful tool for assessing the time-dependent intraoperative blood flow during surgical removal of cerebral AVMs. Microsope-integrated colour-encoded aICG-VAG was used for the surgical treatment of a 38-year-old woman diagnosed with an incidental AVM, Spetzler Martin grade I, of the left frontal lobe and of a 26-year-old man suffering from seizures caused by a symptomatic AVM, Spetzler Martin grade III, of the right temporal lobe. Analytical ICG-VAG visualization was intraoperatively correlated with in situ micro-Doppler investigation, as well as preoperative and postoperative digital subtraction angiography (DSA). Analytical ICG-VAG is fast, easy to handle and integrates intuitively into surgical procedures. It allows colour-encoded visualization of blood flow distribution with high temporal and spatial resolution. Superficial major and minor feeding arteries can be clearly separated from the nidus and draining veins. Effects of stepwise vessel obliteration on velocity and direction of AVM blood flow can be objectified. High quality of visualization, however, is limited to the site of surgery. Colour-encoded aICG-VAG with FLOW 800 enables intraoperative real-time analysis of arterial and venous vessel architecture and might, therefore, increase efficacy and safety of neurovascular surgery in a selected subset of superficial AVMs.


Subject(s)
Cerebral Angiography/methods , Indocyanine Green , Intracranial Arteriovenous Malformations/diagnostic imaging , Intracranial Arteriovenous Malformations/surgery , Monitoring, Intraoperative/methods , Video-Assisted Surgery/methods , Adult , Coloring Agents , Female , Humans , Intracranial Arteriovenous Malformations/pathology , Male