Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Clin Nucl Med ; 45(12): 965-966, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32804760

ABSTRACT

We describe the results of F-FDG PET/CT of 3 patients referred to our institution during the single day of Monday, March 23, 2020, for an initial assessment of cancer extension or for the therapeutic evaluation of chemotherapy of neoplastic pathology, with no obvious infectious or respiratory symptoms at the time of examination. A retrospective review of the recent clinical history of patients in association with the typical pulmonary images on CT scan suggested the diagnosis of COVID-19. The characteristic aspects of COVID-19 infection should be recognized on F-FDG PET/CT, even if patients are asymptomatic or minimally symptomatic.


Subject(s)
Betacoronavirus , Coronavirus Infections/diagnostic imaging , Neoplasms/complications , Pneumonia, Viral/diagnostic imaging , COVID-19 , Coronavirus Infections/complications , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/complications , Positron Emission Tomography Computed Tomography , Retrospective Studies , SARS-CoV-2
2.
Eur J Nucl Med Mol Imaging ; 47(10): 2453-2460, 2020 09.
Article in English | MEDLINE | ID: mdl-32556400

ABSTRACT

PURPOSE: The aim of this series of cases is to show the aspects of ventilation/perfusion single-photon emission computed tomography combined with computed tomography (V/Q SPECT/CT) in patients hospitalized for COVID-19 pneumonia, with the worsening of respiratory symptoms raising the suspicion of a pulmonary embolism. Patients did not benefit from CT angiography for various reasons: a contraindication, unavailability of the CT angiography, or a low clinical probability for pulmonary embolism. METHODS: We retrospectively describe the results of the V/Q SPECT/CT of five patients hospitalized for COVID-19 pneumonia in the nuclear medicine departments of the Centre Cardiologique du Nord and of the Delafontaine hospital in Saint-Denis (Ile-de-France, France) between April 2, 2020, and April 10, 2020. These patients had persistent dyspnea or chest pain suggesting pulmonary embolism. RESULTS: The V/Q SPECT/CT allowed to diagnose a pulmonary embolism in one of these five patients. We also noted several characteristics of the perfusion and ventilation depending on the lung lesions on the CT scan. The areas affected by COVID-19 were most often responsible for ventilatory anomalies with a relatively preserved perfusion. In more advanced cases of pneumonia, with alveolar fillings, the perfusion was also reduced or absent in accordance with large ventilation defects. In addition, the healthy parenchyma appeared to benefit from an uptake in ventilation and perfusion. CONCLUSION: V/Q SPECT/CT can play a role in the management of patients hospitalized for COVID-19 for the diagnosis of embolic complications with meticulous hygienic precautions. The different characteristics of the ventilatory and perfusion anomalies related to COVID-19 pneumonia will be confirmed with the next cases. In addition, in this pandemic context and facing a significant infectious risk, the utility of ventilation will also have to be specified.


Subject(s)
Coronavirus Infections/diagnostic imaging , Lung/diagnostic imaging , Pneumonia, Viral/diagnostic imaging , Single Photon Emission Computed Tomography Computed Tomography , Adult , Aged , Blood Coagulation , COVID-19 , Disease Progression , Dyspnea/complications , Female , France , Hospitalization , Humans , Male , Middle Aged , Pandemics , Probability , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/virology , Retrospective Studies , Ventilation-Perfusion Ratio
3.
J Nucl Cardiol ; 27(3): 737-747, 2020 06.
Article in English | MEDLINE | ID: mdl-30478657

ABSTRACT

BACKGROUND: We studied the impact of technetium-99m (99mTc) in the thallium-201 (201Tl) energy window (70 keV) to determine if CZT cardiac cameras allow us to perform simultaneous dual-isotope acquisition for myocardial perfusion imaging. METHODS: We included 117 consecutive patients. We injected 0.7 MBq/kg of 201Tl at stress, performed the first scan (image T1), then injected at rest 2 MBq/kg of 99mTc-tetrofosmin and immediately acquired a second scan with reconstruction in the energy window of thallium (image T2). A corrected thallium image was created by the subtraction of 99mTc downscattered photons (image TS). We compared spectra, image quality, and semiquantitative scores on T1, T2, and TS images. RESULTS: Though T2 images were of worse quality, TS images were of equal quality compared to T1 images in most cases. Scores show an underestimation of abnormalities in 20% of patients on T2 images and in 10% on TS images. CONCLUSIONS: Despite the improved energy resolution of CZT cameras, downscatter of technetium in the 201Tl window leads to an underestimation of the pathological territory in 10% to 20% of cases. It does not allow us to use simultaneous dual-isotope acquisition in clinical practice without additional tools for scatter correction.


Subject(s)
Cadmium , Myocardial Perfusion Imaging/methods , Technetium Tc 99m Sestamibi , Tellurium , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon/methods , Zinc , Aged , Body Mass Index , Exercise Test , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Observer Variation , Organophosphorus Compounds , Organotechnetium Compounds , Reproducibility of Results , Scattering, Radiation
4.
J Nucl Cardiol ; 25(1): 120-130, 2018 02.
Article in English | MEDLINE | ID: mdl-27506702

ABSTRACT

The aim of this study was to assess the prognostic value of normal ultra-low-dose exercise MPI with a CZT camera. METHODS: 1901 consecutive patients without known CAD referred for exercise MPI with 1.8 MBq/kg (0.05 mCi) of Tc99m sestamibi or tetrofosmin and a CZT camera were included prospectively. Patients with an abnormal scan requiring an additional resting image (230) or a submaximal exercise test (271) were excluded. The 1400 remaining patients were followed for 39 months. The primary end-point was cardiac events (cardiac death, nonfatal myocardial infarction, and revascularization). The secondary end-point was noncardiac death. RESULTS: The mean injected activity was 145 ± 37 MBq (3.9 ± 1 mCi), the mean acquisition duration was 10 ± 0.7 minutes, and the mean effective dose was 0.91 ± 0.13 mSv. 1288 patients (92%) achieved full follow-up. We observed 22 cardiac events and 16 noncardiac deaths. The annualized rates were equivalent to 0.55% for cardiac events and 0.37% for noncardiac mortality. CONCLUSIONS: Normal ultra-low-dose exercise MPI with a CZT camera has a high negative predictive value. The effective dose was less than 1 mSv, and the study thus allays concerns about radiation burden.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Exercise Test/methods , Myocardial Perfusion Imaging/methods , Aged , Cadmium , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Technetium Tc 99m Sestamibi , Tellurium , Treatment Outcome , Zinc
5.
Clin Nucl Med ; 42(7): 569-570, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28481795

ABSTRACT

Fusariosis is an opportunistic infection, caused by a filamentous fungus, found on plants and in soil. The treatment of disseminated pattern, seen in immunocompromised patients with severe neutropenia, is difficult because of antifungal therapy resistance. A 12-year-old girl, who was diagnosed with B-cell acute lymphoblastic leukemia, developed multiple widespread skin papules and subcutaneous nodules, at day 20 of consolidation therapy. Histological examination with cultures of skin tissue revealed Fusarium species. Treatment was started with intravenous liposomal amphotericin B and voriconazole. To assess treatment response, FDG PET/CT performed at baseline, at 2 and 4 months, showed a partial response.


Subject(s)
Antifungal Agents/therapeutic use , Fluorodeoxyglucose F18 , Fusariosis/diagnostic imaging , Fusariosis/drug therapy , Positron Emission Tomography Computed Tomography , Amphotericin B/pharmacology , Amphotericin B/therapeutic use , Antifungal Agents/pharmacology , Child , Female , Fusarium/drug effects , Fusarium/physiology , Humans , Skin/microbiology , Skin/pathology , Treatment Outcome , Voriconazole/pharmacology , Voriconazole/therapeutic use
6.
Clin Nucl Med ; 40(11): 888-9, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26284774

ABSTRACT

A 26-year-old man with chronic terminal renal insufficiency under dialysis was referred in our institution for a checkup before kidney transplantation to ensure the absence of malignant neoplasm. The patient had a biological secondary hyperparathyroidism with highly elevated serum parathormon, and treatment with parathyroid surgery was planned before the kidney transplant. Whole-body FDG PET/CT showed no apparent malignant neoplasm, but increased metabolism of the 4 parathyroid gland and the other pitfalls of advanced secondary hyperparathyroidism on chronic renal insufficiency: pseudotumoral calcification in soft tissues, diffuse hypermetabolic bone dystrophy, and osteolytic lesion of pelvic and peripheral skeleton corresponding to brown tumors.


Subject(s)
Calcinosis/diagnostic imaging , Fluorodeoxyglucose F18 , Hyperparathyroidism, Secondary/diagnostic imaging , Positron-Emission Tomography , Renal Insufficiency/diagnostic imaging , Tomography, X-Ray Computed , Adult , Bone and Bones/diagnostic imaging , Calcinosis/complications , Humans , Hyperparathyroidism, Secondary/complications , Male , Multimodal Imaging , Parathyroid Glands/diagnostic imaging , Radiopharmaceuticals , Renal Insufficiency/complications
7.
Clin Nucl Med ; 40(10): 808-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26204208

ABSTRACT

A 17-year-old adolescent girl was admitted with chronic arthralgia, Raynaud phenomenon, pericarditis, and evidences of chronic diffuse inflammation. F-FDG PET/CT scan was performed to search systemic vasculitis and showed diffuse moderate uptake in the kidneys. We suggested the existence of a nephritis, but the ultrasonography result was normal, and no treatment was introduced. Another F-FDG PET/CT scan was performed 7 months later to explore abdominal pain. It showed again diffuse intense uptake in both kidneys. A proteinuria was highlighted, and renal biopsy allowed to diagnose IgG4-related disease.


Subject(s)
Fluorodeoxyglucose F18 , Immunoglobulin G/immunology , Multimodal Imaging , Nephritis, Interstitial/diagnostic imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Adolescent , Female , Humans , Nephritis, Interstitial/immunology , Radiopharmaceuticals
8.
Clin Nucl Med ; 37(8): e211-2, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22785531

ABSTRACT

We report our first experience of brain DaTSCAN SPECT imaging using cadmium-zinc-telluride gamma camera (CZT-GC) in 2 cases: a 64-year-old patient suffering from essential tremor and a 73-year-old patient presenting with atypical bilateral extrapyramidal syndrome. In both cases, 2 different acquisitions were performed and compared, using a double-head Anger-GC, followed immediately by a second acquisition on CZT-GC. There were no significant visual differences between images generated by different GC. Our first result suggests that DaTSCAN SPECT is feasible on CZT-GC, allowing both injected dose and acquisition time reductions without compromising image quality. This experience needs to be evaluated in larger series.


Subject(s)
Cadmium , Gamma Cameras , Tellurium , Tomography, Emission-Computed, Single-Photon/instrumentation , Tomography, Emission-Computed, Single-Photon/methods , Zinc , Aged , Humans , Male , Middle Aged , Tropanes
9.
Nucl Med Commun ; 33(5): 464-9, 2012 May.
Article in English | MEDLINE | ID: mdl-22240935

ABSTRACT

OBJECTIVES: Thallium-201 is efficient for myocardial perfusion imaging, but leads to relatively high radiation exposure in patients. The purpose of this study was to compare the efficiency of low-dose thallium-201 imaging with cadmium-zinc-telluride (CZT) cameras with regular-dose thallium-201 imaging with conventional cameras. METHODS: We prospectively studied 137 consecutive patients referred for stress myocardial perfusion imaging who had previously had a myocardial single-photon emission computed tomography with thallium-201. We injected at stress a low dose of thallium-201 (1.1 MBq/kg, 28 µCi/kg), performed a 5-7 min scan with a CZT camera (GE DNM 530c), and assessed redistribution imaging when the initial images were abnormal. We compared the CZT scan with the conventional dual-head tomographic camera scan taken previously with a regular dose of thallium-201. RESULTS: The average delay between both scans was 22 months. The stress dose was 88 ± 16 (2.38 ± 0.43 mCi) versus 125 ± 13 MBq (3.38 ± 0.34 mCi; a 30% reduction). The time for camera acquisition was 6 versus 13 min (a 54% reduction). The myocardial counts were increased two-fold with CZT (mean: 446 Kcounts). The quality of CZT images was better in 69% of the cases. There were 59 artifacts with conventional cameras and 29 artifacts with CZT (P<0.01). The diagnostic agreement was calculated in patients without clinical or angiographic changes between both scans (115 patients) and was high (97%). The effective dose at stress was less than 12 mSv. High myocardial counting allowed for further decrease in the injected activity, leading to an effective dose as low as 8 mSv. CONCLUSION: With reduced activities of thallium-201 and low effective doses, the CZT camera provides reliable, high-quality imaging.


Subject(s)
Myocardial Perfusion Imaging/instrumentation , Thallium Radioisotopes/administration & dosage , Aged , Cadmium , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Reproducibility of Results , Tellurium , Zinc
10.
Clin Nucl Med ; 36(11): e178-9, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21975418

ABSTRACT

A 70-year-old man underwent a thallium-201 brain SPECT in the work-up and characterization of a frontotemporal mass. SPECT images were performed on cadmium zinc telluride system during only 5 minutes and after the injection of only 2 mCi. Images demonstrated high thallium uptake in frontotemporal areas considered as a potential malignant tumor. Surgical removal confirmed the diagnosis of malignant glioblastoma. The thallium SPECT fast acquisition imaging on cadmium zinc telluride systems is feasible with reduced injected dose. This method allows a significantly decrease of patient radiation exposure without compromising the image quality. This initial experience needs to be confirmed and optimized in larger clinical studies.


Subject(s)
Brain/diagnostic imaging , Brain/pathology , Cadmium , Tellurium , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon , Zinc , Aged , Glioblastoma/diagnostic imaging , Glioblastoma/pathology , Glioblastoma/radiotherapy , Glioblastoma/surgery , Humans , Male
11.
Clin Nucl Med ; 36(9): 776-80, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21825848

ABSTRACT

PURPOSE OF THE REPORT: Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in myocardial perfusion imaging. However, they had not been yet validated with thallium-201. This study compares the clinical performances of the CZT ultrafast camera GE DNM 530c with a conventional SPECT camera (CC) using thallium-201. MATERIALS AND METHODS: We prospectively studied with thallium-201 a total of 153 consecutive patients referred for myocardial perfusion imaging at exercise (3-4 mCi) then redistribution (with 1 mCi reinjection). Sequential acquisitions were performed first with a conventional dual-head tomographic Anger camera (CC) in 10 to 15 minutes and then with a CZT camera (CZT) in 5 minutes, in prone position. RESULTS: In all, 9 patients were excluded: 1 for mispositioning, 3 for camera failure, 3 for delayed acquisition after exercise, 1 for nonacceptance of redistribution, 1 for motion. Acquisition was more comfortable with CZT for all patients. Global counts rate was higher with CZT than with CC (3.6±0.57 KCts/s vs. 1.14±0.16). CZT has a 5-fold increased myocardial counts rate compared with CC (448±69 Kcts in 5 minutes vs. 209±40 Kcts in 12.5±1.8 minutes). Quality of CZT images was considered as better in 40%, equal in 56%, and worse in 4% of cases; we found less artifacts with CZT; diagnostic conclusions were the same in 140 of 144 cases (97%); discordances were 2 artifacts with CC and 2 small ischemia (less than 2 segments) missed by CZT. CONCLUSIONS: This new dedicated cardiac CZT camera allows with thallium-201 five minutes acquisitions with an increased image quality and a reliable diagnosis quality.


Subject(s)
Cadmium , Gamma Cameras , Myocardial Perfusion Imaging/instrumentation , Tellurium , Thallium Radioisotopes , Tomography, Emission-Computed, Single-Photon/instrumentation , Zinc , Adult , Aged , Aged, 80 and over , Artifacts , Female , Gamma Cameras/standards , Humans , Male , Middle Aged , Tomography, Emission-Computed, Single-Photon/standards
12.
Nucl Med Commun ; 30(1): 62-7, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19306515

ABSTRACT

OBJECTIVES: Septal perfusion abnormalities are frequently observed in patients with left bundle branch block (LBBB). The aim of this study was to compare myocardial perfusion imaging obtained from ungated and diastolic thallium gated single-photon emission computed tomography (SPECT) images in patients with LBBB. METHODS: Stress/rest SPECT was performed in 70 patients with LBBB [38 with coronary artery disease (CAD) (G1), 32 without (G2)] and 19 control participants (G3). Diastolic images were obtained as the sum of four diastolic bins. Perfusion was assessed by summed stress, rest, and difference scores for both diastolic and ungated images. RESULTS: In G1, there was no difference between diastolic and ungated perfusion scores. In G2, summed stress score and summed rest score were increased in diastolic versus ungated imaging, and perfusion defect extent was increased on diastolic versus ungated images at stress (diastole: 6.2 +/- 9.9% vs. ungated: 5.1 +/- 9.70/%, P = 0.01) and rest (diastole: 4.3 +/- 9.3% vs. ungated: 2.8 +/- 9.50%, P = 0.0014), with an increased extent of reversible defect (diastole: 3.4 4.7% vs. ungated: 2.3 3.7%, P = 0.01). In G2, diastolic images failed to correct septal perfusion abnormalities. The number of normal SPECT did not increase with diastolic versus ungated imaging (24 and 180% in G1, 66 and 53% in G2, respectively). Otherwise, a significant association between left ventricular dysfunction and CAD was found, stress ejection fraction being decreased in 20 patients (53%) in G1 and seven patients (22%) in G2 (CHI2 = 6.93, P < 0.01). CONCLUSION: In patients with LBBB, diastolic imaging did not provide additional information to ungated perfusion imaging, but left ventricular dysfunction was associated with CAD.


Subject(s)
Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/physiopathology , Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography/methods , Diastole , Myocardial Perfusion Imaging/methods , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...