1.
Acta Ortop Mex ; 22(4): 247-53, 2008.
Article in Spanish | MEDLINE | ID: mdl-18979988

ABSTRACT

INTRODUCTION: This medical and engineering work explains the process carried out to build a four-barred polycentric knee mechanism using a mechanical actuator for modular prosthetics. Imitation of the knee performance was the main goal, as well as to cover the basic needs of amputated patients with a low production cost. MATERIALS AND METHODS: The polycentric knee mechanism was developed in three stages. The first one was the design and building of the four-barred mechanism using materials as stainless steel 304 and aluminum 6,061 which both have high reliability, corrosion resistance and a relatively easy modeling capability. The total mass was of 700 g. Autocad was used for design and effort analysis was done by using ANSYS. At the end of the first stage, it was observed that its density did not allow mass optimization and no assistant actuator was available for the walking movement. In the second stage, mechanism mass estimation was done by using Alumold 400; this material brings lower density than stainless steel keeping strength and fatigue resistance higher than aluminum 6061. The better ergonomic device was built; a mechanical actuator based on a spring was implemented and tested on two female patients, one geriatric and one 16 years old. The third stage will be described in a future publication, the device mass was optimized by using poly-tetra-fluor-ethylene enhanced with carbon and carbon fiber. Also, the mechanical actuator was complemented with reo-magnetic liquid addition and an electronic control. RESULTS AND DISCUSSION: At the end of this research, an external polycentric knee mechanism was developed, by observing movement stages, velocities, ergonomics, shapes, sizes and significant weights of Mexican patients. Effort analysis by finite element was done and it was determined that the mechanism was capable of modifying its center of rotation according to the knee flexion angle making it a polycentric mechanisms. Also, it was tested on two patients, both females, one 16 and one 75 years old.


Subject(s)
Amputees , Knee Joint , Prostheses and Implants , Adolescent , Aged , Biomechanical Phenomena , Female , Humans , Prosthesis Design
2.
Rev. mex. ortop. traumatol ; 13(1): 53-4, ene.-feb. 1999. graf
Article in Spanish | LILACS | ID: lil-254702

ABSTRACT

El manejo de las fracturas supracondíleas de codo en niño, es controversial y complicado, tanto por la severidad de la lesión, como la capacidad de afectar estructuras vasculares y nerviosas. Por lo que es importante elegir un tratamiento correcto. La reducción cerrada e inmovilización ofrece buenos resultados en las fracturas tipo I y II de la clasificación de Holmberg. La reducción abierta y la osteosíntesis con clavillos de Kirschner es el método recomendado de los tipos III, IV y V por permitir en una mejor reducción. Este es un estudio retrospectivo, observacional y longitudinal de 107 niños con fractura supracondílea que ingresaron a nuestro hospital en el periodo de marzo de 1994 a marzo de 1997. Se excluyeron los tipos I y II por tratarse conservadoramente. Correspondieron 68 (77 por ciento) al sexo masculino y 29 (23 por ciento) al femenino; el lado derecho se presenta en 42 (37 por ciento) pacientes y 65 (61 por ciento) al izquierdo; 82 (76.6 por ciento) correspondieron al tipo III, 21 (19.6 por ciento) al tipo IV y 4(3.7 por ciento) al tipo V. Se encontró que el 90 por ciento de los pacientes tuvieron buenos resultados, 8 por ciento regulares y dos por ciento malos. Como complicaciones tuvimos dos necrosis cutáneas e infección, cuatro pacientes presentaron limitación a la flexión de codo y dos pacientes con consolidación en varo, atribuibles a una reducción inadecuada. Recomendamos la reducción abierta en las fracturas tipo III, IV y V porque siempre encontramos un componente rotacional, que debe corregirse


Subject(s)
Humans , Animals , Male , Female , Child, Preschool , Fracture Fixation, Internal/methods , Humeral Fractures/surgery , Humeral Fractures/classification , Humeral Fractures/diagnosis , Prospective Studies , Longitudinal Studies
3.
Rev. mex. ortop. traumatol ; 12(1): 77-8, ene.-feb. 1998.
Article in Spanish | LILACS | ID: lil-248274

ABSTRACT

Se estudiaron 34 artroplastías de este tipo en el Servicio de Ortopedia del Hospital Juárez de México, la evaluación de los pacientes se hizo según los lineamientos de la Sociedad Americana de Rodilla. En todos los casos se resecó el ligamento cruzado posterior sin observar inestabilidad anterioposterior, los resultados del estudio en 32 pacientes fueron muy buenos en un 32.4 por ciento, buenos un 52.9 por ciento y malos en un 5.8 por ciento presentando complicaciones como necrosis cutáneo en un caso e infección en otro


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Arthroplasty , Posterior Cruciate Ligament , Orthopedic Fixation Devices , Knee Prosthesis/classification
4.
Rev. mex. ortop. traumatol ; 11(4): 262-4, jul.-ago. 1997. ilus
Article in Spanish | LILACS | ID: lil-227155

ABSTRACT

En el Hospital Juárez de México, de enero de 1994 al mes de junio de 1995, se efectuaron 10 osteotomías humerales rotadora en 10 pacientes por luxación recidivante de hombro, con lesión de Hill-Sach, que no fue diagnosticada por el método convencional de radiografía simple, sino por tomografía axial computarizada. Los 9 pacientes del sexo masculino y uno femenino, de 19 a 30 años de edad, con edad promedio de 24 años. Presentaron un promedio de seis luxaciones por paciente. La lesión de Hill-Sach fue confirmada transoperatoriamente. El tratamiento de la luxación recidivante de hombro con lesión de Hill-Sach fue descrito por primera vez por B. G. Weber en 1964. Al efectuar una osteotomía humeral rotacional en forma experimental; de 1967 a 1981, efectuó un promedio de 207 osteotomías con buenos resultados. La osteotomía se llevó a cabo en el tercio proximal del húmero con una rotación externa de 20 a 25 grados. Se fijó con una placa de media caña de seis orificios, más plicatura del tendón subescapular. Los pacientes se inmovilizaron con un vendaje elástico por tres semanas para continuar con un cabestrillo y efectuar movimiento ligero durante otras tres semana; al notar datos radiografícos de consolidación, se inició la rehabilitación forzada. Los resultados con respecto a estabilidad, fuerza y movimiento fueron buens, sólo se tuvo un caso de retardo de consolidación, el cual prolongado el tiempo de inmovilización, llegó a la consolidación. No se reportaron casos de infección, ni de intolerancia al material de osteosintesis. La disminución de la rotación externa del brazo fue de 10 grados aproximadamente


Subject(s)
Humans , Male , Female , Adult , Osteotomy , Tomography , Shoulder Dislocation/surgery , Shoulder Dislocation/complications
SELECTION OF CITATIONS