Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Strength Cond Res ; 37(7): 1404-1410, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37347944

ABSTRACT

ABSTRACT: Rial-Vázquez, J, Nine, I, Guerrero-Moreno, JM, Rúa-Alonso, M, Fariñas, J, Márquez, G, Giráldez-García, MA, Méndez-Bouza, KY, López-Pillado, H, Coutado-Sánchez, E, Losada-Rodríguez, A, and Iglesias-Soler, E. Face masks at the gym: physiological responses and mechanical performance are not compromised by wearing surgical or filtering facepiece 2 masks in healthy subjects. J Strength Cond Res 37(7): 1404-1410, 2023-This study explored the effects of wearing 2 types of face masks on mechanical performance and physiological responses during high-intensity resistance exercise. Twelve healthy men performed 3 workout protocols in a randomized order: wearing a surgical or filtering facepiece 2 (FFP2) mask or without a mask. Each workout consisted of 3 sets of 10 repetitions of bench press (BP) and parallel squat (SQ) with a 12 repetition maximum load, including 2 minutes of recovery between sets and exercises. Mechanical performance was evaluated through the mean propulsive velocity and the number of repetitions completed during each session. Physiological responses were the oxygen saturation (SpO2), blood lactate concentration, heart rate (HR), and HR variability. Perceived exertion was recorded after each set, and The Beck Anxiety Inventory scale was completed at the end of each workout. The number of repetitions completed and the session mean propulsive velocity {(BP [m·s-1]: surgical: 0.35 ± 0.05; FFP2: 0.36 ± 0.04; nonmask: 0.38 ± 0.06) and (SQ: surgical: 0.43 ± 0.05; FFP2: 0.40 ± 0.07; nonmask: 0.41 ± 0.05)} were similar between conditions (p > 0.05). Heart rate recorded during sessions was similar across conditions: surgical: 119 ± 14, FFP2: 117 ± 13, and nonmask: 118 ± 10 bpm (p = 0.919). Face masks had no effect on SpO2, blood lactate concentration, HR variability, perceived exertion, and anxiety values (p > 0.05). Face masks do not compromise strength performance, physiological parameters, and perceived comfort of young and healthy individuals during a high-intensity resistance training session.


Subject(s)
Fitness Centers , Humans , Male , Exercise/physiology , Healthy Volunteers , Lactic Acid , Masks
2.
J Sports Sci ; 37(22): 2596-2603, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31354059

ABSTRACT

This study aimed to compare the goodness of fit and the reliability of different regression models for fitting the force-velocity relationship (FV) of bench press (BP) and squat (SQ). Additionally, the reliability of the position on FV of the velocity (V1RM) and the force performed with the 1RM (F1RM) was explored. Nine rugby players and 12 judokas participated in this study. The FV of BP and SQ were obtained twice by a protocol performed until the 1RM. Individual FV were fitted by linear (LM), quadratic polynomial (PM), and exponential models (EM). Adjusted coefficients of determination of LM and PM (medians higher than 0.919) were higher than for EM. The reliability was higher for LM in comparison with PM. The reliability of V1RM was not acceptable (CV% = 19 and 18% for BP and SQ). High reliability was observed for F1RM (CV% = 3 and 2% for BP and SQ) and for the ratio between F1RM and the force-axis intercept of FV (CV% = 2 and 4% for BP and SQ). The reliability of the relative values of F1RM around 92 and 87% of F0 for BP and SQ suggests the use of these values for monitoring resistance training programmes.


Subject(s)
Linear Models , Models, Statistical , Resistance Training/methods , Resistance Training/statistics & numerical data , Weight Lifting/physiology , Weight Lifting/statistics & numerical data , Adult , Biomechanical Phenomena , Cross-Sectional Studies , Female , Football/physiology , Humans , Male , Martial Arts/physiology , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...