Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Mater Interfaces ; 2(4): 1052-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20359239

ABSTRACT

A glass substrate, coated with a Parylene film, was coated with ZnO by three different methods: ultrasound, microwave, and microwave-plasma irradiation. These coating modes are simple, efficient, and environmentally friendly one-step processes. The structure of the coated products was characterized and compared using methods such as XRD, HR-SEM, EDS, RBS, and optical spectroscopy. Coating by ZnO nanoparticles was achieved for all three approaches. The products were found to differ in their particle sizes, coating thickness, and depth of penetration. All of the ZnO-Parylene-glass composites demonstrated a significant antibacterial activity against Escherichia coli (Gram negative) and Staphylococcus aureus (Gram positive) strains.


Subject(s)
Anti-Infective Agents/pharmacology , Coated Materials, Biocompatible/chemistry , Glass/chemistry , Microwaves , Polymers/chemistry , Xylenes/chemistry , Zinc Oxide/chemistry , Anti-Infective Agents/chemistry , Escherichia coli/metabolism , Materials Testing , Microbial Sensitivity Tests , Models, Chemical , Staphylococcus aureus/metabolism , X-Ray Diffraction
2.
Vet Comp Orthop Traumatol ; 21(3): 202-10, 2008.
Article in English | MEDLINE | ID: mdl-18536845

ABSTRACT

OBJECTIVES: Titanium implants have a tendency for high bone-implant bonding, and, in comparison to stainless steel implants are more difficult to remove. The current study was carried out to evaluate, i) the release strength of three selected anodized titanium surfaces with increased nanohardness and low roughness, and ii) bone-implant bonding in vivo. These modified surfaces were intended to give improved anchorage while facilitating easier removal of temporary implants. MATERIAL AND METHODS: The new surfaces were referenced to a stainless steel implant and a standard titanium implant surface (TiMAX). In a sheep limb model, healing period was 3 months. Bone-implant bonding was evaluated either biomechanically or histologically. RESULTS: The new surface anodized screws demonstrated similar or slightly higher bone-implant-contact (BIC) and torque release forces than the titanium reference. The BIC of the stainless steel implants was significant lower than two of the anodized surfaces (p = 0.04), but differences between stainless steel and all titanium implants in torque release forces were not significant (p = 0.06). CONCLUSION: The new anodized titanium surfaces showed good bone-implant bonding despite a smooth surface and increased nanohardness. However, they failed to facilitate implant removal at 3 months.


Subject(s)
Device Removal/veterinary , Osseointegration/physiology , Titanium , Wound Healing/physiology , Animals , Biomechanical Phenomena , Device Removal/adverse effects , Implants, Experimental , Materials Testing , Sheep/injuries , Sheep/surgery , Stress, Mechanical , Surface Properties , Titanium/chemistry , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...