Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 33(12): 1588-1593, 2022 12.
Article in English | MEDLINE | ID: mdl-35998804

ABSTRACT

PURPOSE: To assess the ability of the Percutaneous Renal Ablation Complexity (P-RAC) scoring system to predict procedural complexity or adverse events (AEs) in adult patients undergoing percutaneous thermal ablation of renal tumors. MATERIALS AND METHODS: A retrospective review of 240 consecutive adult patients who underwent percutaneous thermal renal ablation from 2004 to 2018 was conducted. The P-RAC score was calculated for each renal tumor and procedural complexity recorded. A correlation coefficient was calculated for the P-RAC score and both the number of probes used and procedural duration. Receiver operating characteristic curves assessed the score's ability to predict the use of adjunctive techniques and/or major AEs, classified according to the Society of Interventional Radiology guidelines. RESULTS: For the entire cohort, there was a weak correlation between P-RAC scores and both the number of probes used (r = 0.31; P < .001) and procedural duration (r = 0.18; P = .03). When evaluating only patients treated with microwave ablation (MWA), no correlation between P-RAC scores and either the number of probes (P = .7) used or procedural duration (P = .4) was found. The area under the curve (AUC) for the P-RAC score to predict the use of adjunctive techniques was 0.55 and 0.53 for the entire cohort and MWA group, respectively. The AUC for the P-RAC score to predict major AEs was 0.70, 0.71, and 0.73 for the entire cohort, MWA group, and cryoablation group, respectively. CONCLUSIONS: The P-RAC scoring system is limited in its ability to predict percutaneous thermal renal tumor ablation procedural complexity, especially in patients treated with MWA. The scoring system may have a role in identifying patients at risk of major AEs.


Subject(s)
Carcinoma, Renal Cell , Catheter Ablation , Cryosurgery , Kidney Neoplasms , Adult , Humans , Cryosurgery/adverse effects , Cryosurgery/methods , Carcinoma, Renal Cell/surgery , Microwaves/adverse effects , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Kidney Neoplasms/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Retrospective Studies , Treatment Outcome
2.
J Vasc Interv Radiol ; 31(11): 1874-1885, 2020 11.
Article in English | MEDLINE | ID: mdl-33129433

ABSTRACT

PURPOSE: To assess the feasibility of inducing vascular occlusion by application of radiofrequency (RF) energy via conductive endovascular wires or baskets. MATERIALS AND METHODS: A retrievable nitinol basket and stainless steel guidewire with a platinum tip were evaluated as conductors for endovascular application of RF energy. Tissue-mimicking thermochromic gel phantoms that change color with heating were cast with 2-, 5-, and 7-mm-diameter lumens and filled with 37 oC saline. After ablation, the phantoms were sectioned, and the thermal footprints were evaluated. Six castrated male domestic swine underwent endovascular ablation using the basket in iliac arteries and guidewires in renal arteries. Post-procedural angiography was performed, and postmortem arterial segments were resected for histopathologic analysis. RESULTS: In the phantom, the depth of thermal change in the 5- and 7-mm lumens averaged 6.3 and 6.0 mm along the basket, respectively, and in the 2- and 5-mm lumens, the depth of thermal change averaged 1.9 and 0.5 mm along the wire, respectively. In the swine, RF energy delivery led to angiographic occlusion at 12 of 13 sites. Thermal injury and occlusion were similar at the proximal, middle, and distal basket treatment zone, whereas injury and occlusion decreased from the proximal to the distal end of the 5-cm wire treatment zone. CONCLUSIONS: Endovascular delivery of RF energy via a conductive basket in medium-sized arteries or a guidewire in small arteries led to acute angiographic and histologic occlusion. The potential to induce stasis might be useful in settings where rapid occlusion is desirable.


Subject(s)
Endovascular Procedures/instrumentation , Iliac Artery/surgery , Radiofrequency Ablation/instrumentation , Renal Artery/surgery , Alloys , Animals , Electric Conductivity , Equipment Design , Feasibility Studies , Hot Temperature , Iliac Artery/pathology , Male , Materials Testing , Models, Animal , Orchiectomy , Platinum , Renal Artery/pathology , Stainless Steel , Sus scrofa
SELECTION OF CITATIONS
SEARCH DETAIL
...