Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
3.
J Clin Neurophysiol ; 33(1): e1-4, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26375660

ABSTRACT

INTRODUCTION: Voltage-gated potassium channel-complex antibodies (VGKC-cAbs) encephalitis, a treatable autoantibody encephalopathy, has been previously reported to clinically mimic sporadic Creutzfeldt-Jakob disease. Among available clinical clues to distinguish them, periodic sharp wave complexes, a typical finding in sporadic Creutzfeldt-Jakob disease, have never been reported in association with VGKC-cAbs encephalitis. CASE PRESENTATION: A 76-year-old man was transferred to a tertiary neurology center with a clinical history of 6-month weight loss, cognitive disturbance, and nonspecific generalized weakness. He had two seizures the month before transfer and then evolved to severe encephalopathy, requiring mechanical ventilation. Periodic sharp wave complexes every 1 to 2 seconds over slowed background were found on EEG, and MRI showed cerebellar and bifrontal cortical T2/FLAIR/DWI hypersignal without restricted diffusion on ADC mapping. Pancorporal positron emission tomography scan was negative. An immunotherapy trial did not improve the patient condition. Therefore, he died after life support withdrawal. Brain autopsy revealed mononuclear neocortex infiltrate without significant spongiosis, and the anti-VGKC test showed a seropositivity of 336 pmol/L (normal, 0-31), 3 month after the patient deceased. CONCLUSIONS: This is the first reported case of VGKC-cAbs encephalitis associated with periodic sharp wave complexes on EEG, which further confuse the differential diagnosis with sporadic Creutzfeldt-Jakob disease. However, the cortical DWI hypersignal without restriction seems to remain a way to discriminate these two entities appropriately, when present. These clues are of paramount importance because VGKC-cAbs encephalitis is a treatable disease.


Subject(s)
Autoimmune Diseases of the Nervous System/immunology , Brain Waves/immunology , Creutzfeldt-Jakob Syndrome/diagnosis , Creutzfeldt-Jakob Syndrome/physiopathology , Encephalitis/immunology , Potassium Channels, Voltage-Gated/immunology , Autoantibodies/immunology , Channelopathies , Diagnosis, Differential , Electrocardiography/methods , Humans
4.
J Oncol Pharm Pract ; 20(6): 426-32, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24395542

ABSTRACT

OBJECTIVES: The main objective was to evaluate the impact of two methods aiming at reducing hazardous drug environmental contamination: the centralization of the priming of IV tubing in the pharmacy and the use of a closed-system transfer device. The secondary objective was to evaluate the satisfaction of pharmacy technicians using a survey. METHODS: Sites in the hematology-oncology satellite pharmacy and care unit were analyzed for the presence of cyclophosphamide, ifosfamide and methotrexate before and after the centralization of the priming of IV tubing in the pharmacy and before and after using a closed-system transfer device. The limits of detection for cyclophosphamide, ifosfamide and methotrexate were, respectively, of 0.0015 ng/cm(2), 0.0012 ng/cm(2) and 0.0060 ng/cm(2). The pharmacy technician satisfaction was evaluated using a questionnaire. RESULTS: A total of 225 samples was quantified. After the centralization of priming in the pharmacy, no significant difference was found in the proportion of positive samples for cyclophosphamide, ifosfamide and methotrexate. Traces of cyclophosphamide found on the floor in patient care areas was significantly reduced (median[min-max] 0.08[0.06-0.09]ng/cm(2) vs. 0.03[0.02-0.05], p < 0.0001). After using a closed-system transfer device, a significant difference was found for the proportion of cyclophosphamide positive samples (15/45(33%) vs. 0/45(0%), p < 0.0001), but no significant difference was found for ifosfamide (12/45(27%) vs. 5/45(11%), p = 0.059) and methotrexate (1/45(2%) vs. 2/45(4%), p = 0.557). Pharmacy technicians raised issues following the centralization of priming (e.g. workload) and the use of closed-system transfer devices (e.g. spills, particles, workload and handling difficulties). CONCLUSION: The centralization of the priming of IV tubing in the pharmacy reduced floor contamination in patient care areas without increasing surface contamination in the pharmacy. Closed-system transfer devices reduced contamination in pharmacy, but handling issues were raised by pharmacy technicians.


Subject(s)
Antineoplastic Agents/analysis , Drug Compounding/methods , Occupational Exposure/prevention & control , Pharmacy Service, Hospital/methods , Cyclophosphamide/analysis , Drug Compounding/instrumentation , Environmental Monitoring/methods , Equipment Contamination/prevention & control , Humans , Ifosfamide/analysis , Infusions, Intravenous/instrumentation , Methotrexate/analysis , Occupational Exposure/analysis , Pharmacy Technicians/psychology , Prospective Studies , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...