Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Interv Card Electrophysiol ; 55(2): 233-237, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31177353

ABSTRACT

PURPOSE: Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no study comparing the level of exposure of physicians during different electrophysiology procedures. We aimed to measure and compare cardiologists' exposure to radiation during different electrophysiology procedures. METHODS: The study population comprised all electrophysiology procedures performed over a 6-month period in a large referral centre. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on the operator's left arm. RESULTS: In total, 150 electrophysiology procedures were analyzed. Compared with electrophysiology studies (reference category), physician radiation exposure was 3-fold greater during ablation of atrial fibrillation, 9-fold greater during ablation of atrioventricular nodal reentrant tachycardia (AVNRT)/atrioventricular reentrant tachycardia (AVNT), and 10-fold greater during ablation of atrial flutter (p < 0.001). Physician exposure was mainly related to X-ray time (R2 = 0.28). CONCLUSIONS: Our study showed significant differences in cardiologists' exposure to ionizing radiation depending on the type of electrophysiology procedure. Atrial flutter and AVNRT/AVNT ablations are the procedures in which operators are most exposed to ionizing radiation.


Subject(s)
Cardiologists , Electrophysiologic Techniques, Cardiac , Occupational Exposure , Radiation Exposure , France , Humans , Radiometry , Risk Factors
2.
J Radiol Prot ; 39(2): 489-497, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30913548

ABSTRACT

Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to 'classical' implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on operator's chest. In total, 169 PM/ICD implantations were analysed, 19 of which included CRT. Compared with 'classical' implantation, cardiologist radiation exposure was 9-fold greater during CRT procedures (p < 0.001). Physician exposure was related to dose-area product (R2 = 0.21 during 'classical' implantations and R2 = 0.57 during CRT procedures). Our study shows that cardiologists' exposure to radiation during CRT implantation was 9-fold greater than during procedures without CRT.


Subject(s)
Cardiac Resynchronization Therapy , Cardiology , Defibrillators, Implantable , Occupational Exposure/analysis , Pacemaker, Artificial , Prosthesis Implantation , Radiation Exposure/analysis , Aged , Aged, 80 and over , Cardiac Resynchronization Therapy/adverse effects , Epidemiologic Studies , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Implantation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...