Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
G Ital Nefrol ; 41(2)2024 Apr 29.
Article in Italian | MEDLINE | ID: mdl-38695232

ABSTRACT

Introduction. The Triveneto Peritoneal Dialysis (PD) Network aims to bring together doctors and nurses who deal with PD in a collaborative network in which to exchange mutual knowledge and optimize the use of this method of replacing renal function. A topic of particular interest was the management of peritoneal catheter exit-site infection, given the recent publication of the new guidelines of the International Society of Peritoneal Dialysis (ISPD). Materials and methods. The survey concerned the criteria for carrying out nasal swab and exit-site, management of exuberant granulation tissue "Proud Flesh", treatment of exit-site infection (ESI), use of silver dressings, the role of subcutaneous tunnel ultrasound and cuff shaving. Results. All PD centers in the North-East Italy area have joined the survey with at least one operator per centre. There was a wide variability between the indications for performing the exit-site swab. In the presence of ESI, the prevalent approach is that of oral systemic empiric therapy associated (20.0%) or less (28.9%) with topical therapy, and then adapting it in a targeted manner to the culture examination. Discussion. From the discussion of the survey emerged the importance of the ESI as an outcome indicator, which allows us to verify whether our clinical practice is in line with the reference standards. It is essential to know and base our activity on what is indicated in national and international guidelines and to document the events that occur in the patient population of each dialysis unit.


Subject(s)
Catheter-Related Infections , Peritoneal Dialysis , Practice Guidelines as Topic , Humans , Peritoneal Dialysis/instrumentation , Italy , Catheter-Related Infections/prevention & control , Catheter-Related Infections/etiology , Catheters, Indwelling
2.
Nephrology (Carlton) ; 10(3): 270-3, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15958040

ABSTRACT

Aspergillus peritonitis is a rare disease in continuous peritoneal dialysis. It is a severe form of peritonitis, which is frequently lethal. We report a case of Aspergillus fumigatus peritonitis in a female patient on automated peritoneal dialysis (APD), who was successfully treated with intravenous amphotericin B and the removal of the peritoneal catheter. As delayed treatment has an increased mortality rate, it is mandatory to remove the catheter and to start intravenous treatment with amphotericin B empirically.


Subject(s)
Aspergillosis/drug therapy , Aspergillus fumigatus , Kidney Failure, Chronic/therapy , Peritoneal Dialysis, Continuous Ambulatory/adverse effects , Peritonitis/drug therapy , Aged , Amphotericin B/administration & dosage , Amphotericin B/adverse effects , Antifungal Agents/administration & dosage , Antifungal Agents/adverse effects , Drug Therapy, Combination , Female , Humans , Itraconazole/administration & dosage , Itraconazole/adverse effects , Kidney Failure, Chronic/complications , Peritonitis/microbiology
3.
Kidney Int ; 67(1): 301-13, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15610256

ABSTRACT

BACKGROUND: In suspended cells, low-frequency current only passes through extracellular fluids, while current at higher frequencies passes through extra- and intracellular fluids. Cells in soft tissues are in contact with each other, which causes tissue anisotropy, meaning that impedance changes along different cell directions, with part of low-frequency current also passing through cells. Hence, equivalent information on body impedance change is expected at all frequencies, which we proved in a dynamic condition of fluid removal with hemodialysis. METHODS: We performed whole-body impedance spectroscopy (496 frequencies from 4 to 1024 kHz, SEAC SFB3 analyzer; Brisbane, Australia) before and during fluid removal (0, 60, 120, 180 min, 2.5 kg) in 67 hemodialysis patients. With increasing current frequency, resistance (R) decreases and reactance (Xc) moves along the Cole's semicircle on the R-Xc plane. RESULTS: The Cole's semicircles progressively enlarged and moved to the right on the R-Xc plane following fluid removal (increase in both R and Xc values at any given frequency). Xc values at 5 kHz (expected values close to 0 Ohm) were 70% of the maximun Xc, indicating an intracellular current flows at low frequencies. The correlation coefficient between R at 50 kHz (standard frequency) and R at other frequencies ranged from 0.96 to 0.99, and the correlation coefficient between Xc at 50 kHz and Xc at other frequencies at any time point ranged from 0.65 to 0.99. CONCLUSION: From high Xc values at low frequency, tissue anisotropy is inferred. Intra- and extracellular current flow causes equivalence of information based on functions of R and Xc measurements made at 50 kHz versus other frequencies.


Subject(s)
Body Composition , Electric Impedance , Renal Dialysis , Aged , Aged, 80 and over , Body Fluid Compartments , Cross-Sectional Studies , Data Interpretation, Statistical , Female , Guidelines as Topic , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...