Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Rev Med Pharmacol Sci ; 8(3): 103-6, 2004.
Article in English | MEDLINE | ID: mdl-15368792

ABSTRACT

A new method of orotracheal intubation in mice is described. After intraperitoneal induction of anaesthesia, 36 male animals, belonging to common laboratory strains, have been intubated with the aid of a straight, small bore arthroscope, connected to a video-camera. After the insertion of a guide wire of appropriate size across the vocal cords, a polyethylene (PE) cannula has been introduced over it as an endotracheal tube. Success rate has been 100% both in first intubations and in re-intubations; all procedures have been performed in a mean time of about 3 min. Post-mortem examination of mice did not show any significant damage to upper airway mucosae related to the technique.


Subject(s)
Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Video Recording/instrumentation , Animals , Animals, Laboratory , Endoscopes/trends , Equipment Design , Intubation, Intratracheal/economics , Italy , Male , Mice , Mice, Inbred C57BL , Mice, Inbred Strains , Time Factors , Video Recording/methods