Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Mater Sci Eng C Mater Biol Appl ; 41: 78-82, 2014 Aug 01.
Article in English | MEDLINE | ID: mdl-24907740

ABSTRACT

Magnetostrictive biosensors specific to Salmonella typhimurium were prepared by immobilizing antibody or phage as biorecognition elements onto the magnetostrictive sensor platform. The sensors were stored at temperatures of 25 °C (room temperature), 45 °C and 65 °C, respectively, and the ability to bind S. typhimurium was detected by testing the resonant frequency shift using a HP network analyzer after exposure to 1 mL of 1×10(9) cfu/mL of S. typhimurium at a predetermined schedule. The binding of S. typhimurium to biosensors was confirmed by Scanning Electron Microscopy (SEM). The results showed that there existed an initial sudden drop in the average density of S. typhimurium bound to the biosensor surface versus duration at different temperatures for the two kinds of recognition elements, and the binding ability to S. typhimurium of phage-immobilized biosensors was much better than that of antibody-immobilized biosensors, with longevity longer than 30 days at all tested temperatures, though decreasing gradually over the testing period. While the longevity of antibody-immobilized biosensors was only about 30, 8 and 5 days at room temperature (25 °C), 45 °C and 65 °C, respectively. Meanwhile, the activation energy of the two kinds of biosensors was investigated, and it was found that phage immobilized sensors showed much higher activation energy than antibody immobilized sensors, which resulted in less dependency on temperature and thus having much better thermal stability than antibody immobilized sensors.


Subject(s)
Antibodies/immunology , Bacteriophages/metabolism , Biosensing Techniques , Magnetics , Salmonella typhimurium/isolation & purification , Alloys/chemistry , Antibodies, Immobilized/immunology , Temperature
2.
J Microbiol Methods ; 70(1): 112-8, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17490768

ABSTRACT

In this article, we report the results of an investigation into the performance of a wireless, magnetoelastic biosensor designed to selectively detect Salmonella typhimurium in a mixed microbial population. The Langmuir-Blodgett (LB) monolayer technique was employed for antibody (specific to Salmonella sp.) immobilization on rectangular shaped strip magnetoelastic sensors (2 x 0.4 x 0.015 mm). Bacterial binding to the antibody on the sensor surface changes the resonance parameters, and these changes were quantified as a shift in the sensor's resonance frequency. Response of the sensors to increasing concentrations (5 x 10(1) to 5 x 10(8) cfu/ml) of S. typhimurium in a mixture of extraneous foodborne pathogens (Escherichia coli O157:H7 and Listeria monocytogenes) was studied. A detection limit of 5 x 10(3) cfu/ml and a sensitivity of 139 Hz/decade were observed for the 2 x 0.4 x 0.015 mm sensors. Binding kinetics studies have shown that the dissociation constant (K(d)) and the binding valencies for water samples spiked with S. typhimurium was 435 cfu/ml and 2.33 respectively. The presence of extraneous microorganisms in the mixture did not produce an appreciable change in the biosensor's dose response behavior.


Subject(s)
Bacteriological Techniques/methods , Biosensing Techniques/methods , Salmonella typhimurium/isolation & purification , Surface Plasmon Resonance/methods , Antibodies, Bacterial/metabolism , Escherichia coli O157/isolation & purification , Kinetics , Listeria monocytogenes/isolation & purification , Sensitivity and Specificity
3.
Biosens Bioelectron ; 22(7): 1474-9, 2007 Feb 15.
Article in English | MEDLINE | ID: mdl-16930986

ABSTRACT

Mass-sensitive, magnetoelastic resonance sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted by the sensor in response to an applied, time varying, magnetic field. This magnetostrictive platform has a unique advantage over conventional sensor platforms in that measurement is wireless and remote. A biosensor for the detection of Salmonella typhimurium was constructed by immobilizing a polyclonal antibody (the bio-molecular recognition element) onto the surface of a magnetostrictive platform. The biosensor was then exposed to solutions containing S. typhimurium bacteria. Binding between the antibody and antigen (bacteria) occurred and the additional mass of the bound bacteria caused a shift in the sensor's resonant frequency. Sensors with different physical dimensions were exposed to different concentrations of S. typhimurium ranging from 10(2) to 10(9)CFU/ml. Detection limits of 5x10(3) CFU/ml, 10(5) CFU/ml and 10(7) CFU/ml were obtained for sensors with the size of 2 mmx0.4 mmx15 microm, 5 mmx1 mmx15 microm and 25 mmx5 mmx15 microm, respectively. Good agreement between the measured number of bound bacterial cells (as measured by scanning electron microscopy (SEM)) and frequency shifts was obtained.


Subject(s)
Antibodies , Biosensing Techniques/instrumentation , Magnetics/instrumentation , Salmonella Infections/diagnosis , Salmonella typhimurium/isolation & purification , Animals , Rabbits , Salmonella Infections/immunology , Salmonella typhimurium/immunology
4.
J Xray Sci Technol ; 7(2): 198-210, 1997 Jan 01.
Article in English | MEDLINE | ID: mdl-21307550

ABSTRACT

In this study, the electric field dependence on the charge collection process of CdZnTe detectors, at different x-ray tube settings, within the x-ray diagnostic energy range, is investigated. In addition, the detector contrast at different applied bias voltages and x-ray tube settings have been experimentally determined. The experimental results suggest that an efficient charge collection process is obtained by increasing the applied bias voltage. Once the applied bias voltage is sufficiently high, charge collection becomes complete and the detector operates in the saturation region. This is a prerequisite for high contrast and spatial resolution. As a result, the detector contrast is enhanced significantly. Therefore, CdZnTe detectors appear to be potential candidates for digital radiographic applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...