Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Intensive Care ; 12(1): 1, 2022 Jan 04.
Article in English | MEDLINE | ID: mdl-34981245

ABSTRACT

BACKGROUND: Ventilator-associated pneumonia (VAP) causes increased mortality, prolonged hospital stay and increased healthcare costs. Prevention of VAP in intensive care units (ICUs) is currently based on several measures, and application of noble metal coating on medical devices has been shown to inhibit the bacterial adherence of microorganisms to the surface. The objective of this study was to evaluate the potential benefit of noble metal coating of endotracheal tubes for the prevention of VAP. METHODS: This was a multi-center, randomized, controlled, double-blind, prospective study including ventilated patients from nine ICUs from four hospital sites in Belgium. Patients were randomly intubated with identical appearing noble metal alloy (NMA) coated (NMA-coated group) or non-coated (control group) endotracheal tubes (ETT). Primary endpoint was the incidence of VAP. Secondary endpoints were the proportion of antibiotic days during ICU stay and tracheal colonization by pathogenic bacteria. RESULTS: In total, 323 patients were enrolled, 168 in the NMA-coated group and 155 in the control group. During ventilation, VAP occurred in 11 patients (6.5%) in the NMA-coated group and in 18 patients (11.6%) in the control group (p = 0.11). A higher delay in VAP occurrence was observed in the NMA-coated group compared with the control group by Cox proportional hazards regression analysis (HR 0.41, 95% CI 0.19-0.88, p = 0.02). The number of antibiotic days was 58.8% of the 1,928 ICU days in the NMA-coated group and 65.4% of the 1774 ICU days in the control group (p = 0.06). Regarding tracheal colonization, bacteria occurred in 38 of 126 patients in the NMA-coated group (30.2%) and in 37 of 109 patients in the control group (33.9%) (p = 0.57). CONCLUSIONS: This study provides preliminary evidence to support the benefit of noble metal coating in the prevention of VAP. A confirmatory study in a larger population would be valuable. TRIAL REGISTRATION: Clinical trial number: NCT04242706 ( http://www.clinicaltrials.gov ).

2.
Crit Care Res Pract ; 2022: 5509081, 2022.
Article in English | MEDLINE | ID: mdl-36590829

ABSTRACT

Introduction: The global burden of stroke is high and mechanical thrombectomy is the cornerstone of the treatment. Incidences of acute non-neurological-complications are poorly described. Improve knowledge about these complications may allow to better prevent, detect and/or manage them. The aim is to identify risk markers of death or poor evolution. Method: We conducted a retrospective single-center study to analyzed the incidence of non-neurologicalcomplications after mechanical thrombectomy in acute ischemic stroke. Patients who had experienced a stroke and undergone thrombectomy were identified using a registry in which we prospectively collected data from each patient admitted to our hospital with a diagnosis of stroke. Quantitative and qualitative variables were analyses. The association between studied variables and hospital death was assessed using simple logistic regression models. Result: 361 patients were reviewed but 16 were excluded due to a lack of medical information. Between 2012 and 2019, 345 patients were included. The median admission NIHSS score was 15. Seven percent of the patients died in the ICU. The following independent risk markers of death in the ICU were identified by logistic regression: respiratory complication, hypotension, infectious complication, and hyperglycemia. Conclusion: In this large retrospective study of stroke, respiratory complications and pulmonary infections represented the most important non-neurological adverse events encountered in the ICU and associated with a risk of death.

3.
Case Rep Crit Care ; 2020: 6962591, 2020.
Article in English | MEDLINE | ID: mdl-33145113

ABSTRACT

Metformin is an oral antidiabetic largely prescribed in the treatment of type II diabetes. Overdose is associated with life-threatening lactic acidosis. We report the case of the highest metformin concentration ever described secondary to a voluntary suicidal intake. The patient developed a severe lactic acidosis and hemodynamic shock successfully treated with high-flow hemofiltration. Time to start extrarenal epuration is capital to avoid poor evolution.

SELECTION OF CITATIONS
SEARCH DETAIL
...