Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Pharmaceuticals (Basel) ; 15(3)2022 Mar 05.
Article in English | MEDLINE | ID: mdl-35337113

ABSTRACT

The glycan profile is a critical quality attribute for pharmaceutical monoclonal antibodies due to the potential physiological impact of the glycan composition when used as a drug product. Monoclonal antibody reference standards are useful as system suitability samples for glycan profile testing. The development of future glycan profiling techniques could be better evaluated by testing well-characterized reference standards. The USP has introduced monoclonal antibody reference standards (i.e., USP mAb 001 RS, USP mAb 002 RS, and USP mAb 003 RS) with the glycan profiles reported herein that can be used to assess the analytical testing of monoclonal antibody glycan profiles. Comparison of the USP reference standards to other available reference standards (NISTmAb) is presented. The glycan profile of the USP monoclonal antibody reference standards covers a range of glycan species that complements other available reference standards. The USP mAb reference standards are a valuable tool that can be used to verify the glycan structure and provide the system suitability of analytical methods.

2.
Anal Biochem ; 612: 113896, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32818506

ABSTRACT

Biologics manufacturers must continually monitor the attachment of carbohydrates, called glycans, to their products, because any variability can impact safety and efficacy. To help the industry meet this challenge, the United States Pharmacopeial Convention (USP) offers glycan reference standards and validated methods for glycoprofiling using high-performance liquid chromatography (HPLC). The industry has recently adopted more advanced technologies for glycan analysis, including ultra-high performance liquid chromatography (UHPLC) and mass spectrometry. In this study, we confirm that USP's glycan reference standards are compatible with UHPLC by demonstrating comparable peak separation and glycan identification to HPLC methods. The improved resolving power and shorter run-times of UHPLC also allowed us to identify many of the minor glycan components present in USP's glycan reference standards. These more comprehensively characterized glycan reference standards will enable manufacturers to assess the micro-heterogeneity that can negatively impact the safety and efficacy of biological products.


Subject(s)
Chromatography, High Pressure Liquid/methods , Chromatography, High Pressure Liquid/standards , Polysaccharides/analysis , Antibodies, Monoclonal/analysis , Glycosylation , Mass Spectrometry , Reference Standards
3.
Anal Biochem ; 592: 113577, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31926146

ABSTRACT

Recombinant influenza Virus-Like Particle (VLP) vaccines are promising vaccine candidates to prevent influenza, contain two major viral antigenic glycoproteins, Hemagglutinin (HA) and Neuraminidase (NA), on the surface of recombinant VLPs. Accurate quantitation of the mass of these antigenic proteins is important to ensure the product quality and proper dosing. Currently, Single Radial Immunodiffusion (SRID) is a recognized assay for determination of the HA immuno-reactive concentration (potency) in vaccine products, based on immuno-reactivity of HA with strain-specific antisera. The SRID assay, however, requires availability of strain-specific and properly calibrated reagents, which can be time-consuming to generate and calibrate. In addition, the assay is not suitable for quantitation of low abundant proteins, such as NA. In order to accelerate the overall production cycle, we have developed and optimized a high-resolution (HR) LC-MS method for absolute quantitation of both HA and NA protein concentrations in influenza VLP vaccine candidates. In this work, we present the method development, optimization and verification of its suitability for the intended purpose, as a prerequisite for its potential application in Quality Control, by assessing specificity, precision and accuracy, detection characteristics, and dynamic linear range. The method can be also used for other HA/NA containing preparations including in-process samples, purified proteins, whole virus preparations, nano-particle and egg-based vaccine preparations, or for calibration of SRID reference antigens.


Subject(s)
Chromatography, Liquid/methods , Hemagglutinin Glycoproteins, Influenza Virus/analysis , Influenza A virus/chemistry , Neuraminidase/analysis , Tandem Mass Spectrometry/methods , Antibodies, Viral/chemistry , Antigens, Viral/analysis , Humans , Influenza Vaccines , Vaccines, Virus-Like Particle
5.
Rapid Commun Mass Spectrom ; 19(19): 2762-6, 2005.
Article in English | MEDLINE | ID: mdl-16134212

ABSTRACT

Direct analysis of laser capture microdissected malignant and normal endometrial epithelium using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (MS) was able to detect a number of proteins that are overexpressed in malignant epithelial cells. A total of 16 physiologic and malignant endometrial samples were laser capture microdissected, including four proliferative and four secretory endometria, and eight endometrioid adenocarcinomas. Two of these proteins, at 10,834 and 10,843 Da, likely correspond to calgranulin A and chaperonin 10, two proteins that had previously been identified in endometrioid adenocarcinoma in whole tissue homogenate by MS analysis. Direct analysis by MALDI-MS not only confirms that these proteins are overexpressed in endometrial carcinoma, but also localizes them to the epithelial cells, the expected cancer site.


Subject(s)
Biomarkers, Tumor/analysis , Endometrial Neoplasms/metabolism , Epithelium/metabolism , Microdissection/methods , Neoplasm Proteins/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Endometrial Neoplasms/diagnosis , Endometrial Neoplasms/pathology , Endometrial Neoplasms/surgery , Epithelium/pathology , Epithelium/surgery , Female , Humans
6.
J Proteome Res ; 4(2): 377-86, 2005.
Article in English | MEDLINE | ID: mdl-15822913

ABSTRACT

A total of nine potential markers for endometrial cancer (EmCa) have been discovered and identified from endometrial tissue homogenates using a combination of differentially labeled tags, iTRAQ and cICAT, with multidimensional liquid chromatography and tandem mass spectrometry. The tissues were snap frozen in liquid nitrogen within 15-20 min after devitalization. Samples for proteomic analysis were treated with protease inhibitors before processing. Marker proteins that were overexpressed in EmCa are chaperonin 10, pyruvate kinase M1 or M2 isozyme, calgizzarin, heterogeneous nuclear ribonucleoprotein D0, macrophage migratory inhibitory factor, and polymeric immunoglobulin receptor precursor; those that were underexpressed are alpha-1-antitrypsin precursor, creatine kinase B, and transgelin. The chaperonin 10 result confirms our earlier observation of overexpression in EmCa tissues using surface-enhanced laser desorption/ionization mass spectrometry, verified by Western analysis and immunohistochemistry [Yang, E. C. C. et al. J. Proteome Res. 2004, 3, 636-643]. Pyruvate kinase was observed to be overexpressed using both iTRAQ and cICAT labeling. All nine markers have been found to be associated with various forms of cancer. A panel of these plus other markers may confer sufficient selectivity for diagnosing and screening of EmCa. The use of cICAT led to identification of a higher proportion of lower-abundance signaling proteins; conversely, iTRAQ resulted in a higher percentage of the more abundant ribosomal proteins and transcription factors.


Subject(s)
Chromatography, Liquid/methods , Endometrial Neoplasms/metabolism , Mass Spectrometry/methods , Feasibility Studies , Female , Humans , Sensitivity and Specificity
7.
Proteomics ; 5(7): 1953-66, 2005 May.
Article in English | MEDLINE | ID: mdl-15816004

ABSTRACT

Surface-enhanced laser desorption/ionization-mass spectrometry (SELDI-MS) has conventionally been practiced on linear time of flight (TOF) which has low mass accuracy and resolution. Here we demonstrate in an examination of both malignant and nonmalignant endometrial tissue homogenates that high mass accuracy and resolution in the MS stage are crucial. Using a commercially available quadrupole/TOF (QqTOF), we were able to resolve two potential cancer markers, subsequently identified off-line as chaperonin 10 and calgranulin A, that differ by 8 Da in mass. Two off-line protein identification protocols were developed: the first was based on size-exclusion chromatography (SEC), sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), protein extraction, trypsin digestion, and matrix-assisted laser desorption/ionization-tandem MS (MALDI-MS/MS); the second on SEC and shotgun nano-liquid chromatography (nanoLC)-MS/MS. Analyses on a cohort of 44 endometrial homogenates showed 22 out of 23 nonmalignant samples had nondetectable to very low abundance of chaperonin 10 and calgranulin A; 17 of the 21 malignant samples had detectable to abundant levels of both proteins. Immunohistochemical staining of a tissue microarray of 32 samples showed that approximately half of malignant endometrial tissues exhibited positive staining for calgranulin A in the malignant epithelium, while 9 out of 10 benign tissues exhibited negative epithelial staining. In addition, macrophages/granulocytes in malignant as well as nonmalignant tissues showed positive staining. No immunostaining occurred in stroma or myometrium. Calgranulin A, in combination with chaperonin 10 and other proteins, may eventually constitute a panel of markers to permit diagnosis and screening of endometrial cancer.


Subject(s)
Biomarkers, Tumor , Calgranulin A/metabolism , Chaperonin 10/metabolism , Endometrial Neoplasms/metabolism , Calgranulin A/chemistry , Chaperonin 10/chemistry , Endometrial Neoplasms/chemistry , Female , Humans , Immunohistochemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
8.
Proteomics ; 5(1): 270-81, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15602768

ABSTRACT

Proteomic analyses of the proliferative and secretory phases of the human endometrium were carried out to identify proteins and discover differentially expressed proteins using isotope-coded affinity tags, three stages of chromatographic separation and online tandem mass spectrometry (MS/MS). From an initial list of 346 proteins identified by ProICAT, manual inspection of MS/MS spectra and confirmatory searches pared the list down to 119 positively identified proteins. Only five of the proteins showed consistent differential expression. The utility of some of these proteins as indicators of true differential expression in the endometrium is open to discussion. The two proteins with unquestionable differential expressions in the secretory endometrium are: glutamate NMDA receptor subunit zeta 1 precursor and FRAT1. Some of the proteins that show no differential expression have previously been examined in gene-expression studies with similar conclusions.


Subject(s)
Endometrium/cytology , Endometrium/metabolism , Proteome/biosynthesis , Adaptor Proteins, Signal Transducing , Chromatography, Liquid , Female , Humans , Intracellular Signaling Peptides and Proteins , Protein Precursors/biosynthesis , Protein Subunits/biosynthesis , Proto-Oncogene Proteins/biosynthesis , Receptors, N-Methyl-D-Aspartate/biosynthesis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
9.
J Proteome Res ; 3(3): 636-43, 2004.
Article in English | MEDLINE | ID: mdl-15253447

ABSTRACT

Endometrial carcinoma is a common malignancy in women, being exceeded in incidence only by that of breast, lung, and colorectal cancers. At present, no serum tumor markers are available for the monitoring of endometrial carcinoma patients, and patients with recurrent disease are detected only following the development of symptoms or abnormalities in imaging assessments. Similarly, no screening tools are available for endometrial carcinoma. Protein profiling by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) has proven to be a sensitive and fast method of analysis for small proteins or peptides to yield specific biomarkers. In this study, a variety of normal and malignant endometrial tissue samples were fractionated and analyzed by SELDI-TOF MS (SELDI is a version of MALDI utilizing protein "chips"). A number of proteins displayed differential expression in malignant endometrial tissues. One of the prominent proteins fractionated by weak cation exchange chromatography and displaying enhanced expression in these malignant tissues was identified as chaperonin 10. The increased expression of chaperonin 10 in malignant endometrial tissues was further confirmed by parallel Western blot and immunohistochemistry analyses.


Subject(s)
Biomarkers, Tumor/chemistry , Chaperonin 10/metabolism , Endometrial Neoplasms/metabolism , Gene Expression Regulation, Neoplastic/genetics , Proteome , Biomarkers, Tumor/blood , Female , Humans , Immunohistochemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
10.
J Am Chem Soc ; 126(25): 7975-80, 2004 Jun 30.
Article in English | MEDLINE | ID: mdl-15212547

ABSTRACT

Despite reports to the contrary, doubly charged lead monohydrate is a stable species against both proton and charge transfers. [Pb(H(2)O)](2+) has been observed as a minor product in the ligand-exchange reaction of [Pb(CH(3)CN)](2+) with H(2)O after collisional activation. Density functional theory has been used to examine reaction profiles of [Pb(H(2)O)(n)](2+) where n = 1, 2, and 3.

SELECTION OF CITATIONS
SEARCH DETAIL
...