J Indian Prosthodont Soc ; 21(1): 45-49, 2021.
Article in English | MEDLINE | ID: mdl-33835067

ABSTRACT

Aim: To compare the rise in temperature using trephines over conventional ones during bone site preparation. Setting and Design: An-vitro, evaluative study. Materials and Methods: Twenty implant sites were prepared using pilot drill up to depth of 10 mm on bovine femoral bone. In first part, no irrigation was used. Five sites were prepared using conventional drill of 2.8 mm, and other five were prepared with help of trephine drills. On completion of each drill, infrared thermometer was used to measure temperature on both the drill tip and the shaft. The same procedure was repeated with bone immersed in saline. Statistical Analysis Used: Student t test was used to evaluate the significance of difference. Result: Study showed that the temperature rise at drill tip was significantly higher for trephine drill (52.98 ± 1.67 °C) than conventional drills (48.20 ± 0.67 °C), however the temperature difference in trephine and conventional drills was statistically insignificant. Conclusion: The temperature increase was more distributed in conventional drills than trephine. Copious irrigation is thus mandatory for trephine drills. Intermittent drilling is preferred with conventional drills.


Subject(s)
Osteotomy , Temperature , Animals , Body Temperature , Bone and Bones , Cattle , Humans , Osteotomy/instrumentation , Thermometers
2.
J Indian Prosthodont Soc ; 14(1): 110-4, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24605007

ABSTRACT

The functional surfaces of the porcelain fused to metal fixed partial dentures are often abraded to adjust occlusion, such restorations are often found to fail in service. This study was therefore conducted to study the effect of surface abrasion on flexural strength of glazed porcelain fused to metal samples. It was also the aim of this study to find the effect of re-glazing on flexural strength of abraded samples. A total of ninety glazed porcelain fused to metal bar samples of the dimension 15 mm × 2 mm × 1.5 mm were fabricated. These samples were then divided into three groups (30 samples each) according to the surface treatments: group A-glazed (control); group B-abraded and group C-abraded and then re-glazed (self-glazed). Flexural strength was measured by using three point bend test on universal testing machine (texture analyser) with a cross-head speed of 0.6 mm/min. Peak force at the time of failure for all the samples was recorded. Statistical analysis found that mean flexural strength was highest for group A-80.65 ± 12.81 MPa; as compared to group B-74.18 ± 10.74 MPa and group C-77.85 ± 9.39 MPa. Student's t test indicated that the difference in the flexural strength between groups A and B was significant while it was non-significant between groups B and C and also between groups A and C. The 'f' test indicated that the difference between the groups was non-significant. This study therefore showed that there is a marked decrease in the flexural strength of the porcelain fused to metal restorations after occlusal abrasion. The study also found that reglazing of these restorations may not restore their flexural strength significantly.

SELECTION OF CITATIONS
SEARCH DETAIL
...