Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Front Optoelectron ; 13(1): 50-72, 2020 Mar.
Article in English | MEDLINE | ID: mdl-36641586

ABSTRACT

The field of topological photonic crystals has attracted growing interest since the inception of optical analog of quantum Hall effect proposed in 2008. Photonic band structures embraced topological phases of matter, have spawned a novel platform for studying topological phase transitions and designing topological optical devices. Here, we present a brief review of topological photonic crystals based on different material platforms, including all-dielectric systems, metallic materials, optical resonators, coupled waveguide systems, and other platforms. Furthermore, this review summarizes recent progress on topological photonic crystals, such as higherorder topological photonic crystals, non-Hermitian photonic crystals, and nonlinear photonic crystals. These studies indicate that topological photonic crystals as versatile platforms have enormous potential applications in maneuvering the flow of light.

2.
Adv Mater ; 32(27): e1903639, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31830340

ABSTRACT

The exploration of quantum-inspired symmetries in optical and photonic systems has witnessed immense research interest both fundamentally and technologically in a wide range of subject areas in physics and engineering. One of the principal emerging fields in this context is non-Hermitian physics based on parity-time symmetry, originally proposed in the studies pertaining to quantum mechanics and quantum field theory and recently ramified into a diverse set of areas, particularly in optics and photonics. The intriguing physical effects enabled by non-Hermitian physics and PT symmetry have enhanced significant application prospects and engineering of novel materials. In addition, there has been increasing research interest in many emerging directions beyond optics and photonics. Here, the state-of-the art developments in the field of complex non-Hermitian physics based on PT symmetry in various physical settings are brought together, and key concepts, a background, and a detailed perspective on new emerging directions are described. It can be anticipated that this trendy field of interest will be indispensable in providing new perspectives in maneuvering the flow of light in the diverse physical platforms in optics, photonics, condensed matter, optoelectronics, and beyond, and will offer distinctive application prospects in novel functional materials.

3.
Opt Express ; 26(19): 24307-24317, 2018 Sep 17.
Article in English | MEDLINE | ID: mdl-30469552

ABSTRACT

Two-dimensional (2D) coupled resonant optical waveguide (CROW), exhibiting topological edge states, provides an efficient platform for designing integrated topological photonic devices. In this paper, we propose an experimentally feasible design of 2D honeycomb CROW photonic structure. The characteristic optical system possesses two-fold and three-fold Dirac points at different positions in the Brillouin zone. The effective gauge fields implemented by the intrinsic pseudo-spin-orbit interaction open up topologically nontrivial bandgaps through the Dirac points. Spatial lattice geometries allow destructive wave interference, leading to a dispersionless, near-flat energy band in the vicinity of the three-fold Dirac point in the telecommunication frequency regime. This nontrivial structure with a near-flat band yields topologically protected edge states. These characteristics underpin the fundamental importance as well as the potential applications in various optical devices. Based on the honeycomb CROW lattice, we design the shape-independent topological cavity and the beam splitter, which demonstrate the relevance for a wide range of photonic applications.

4.
J Vasc Surg ; 65(6): 1793-1801, 2017 06.
Article in English | MEDLINE | ID: mdl-27693031

ABSTRACT

OBJECTIVE: Prosthetic grafts used for lower extremity revascularization and dialysis access fail because of hyperplastic stenosis and thrombosis. Graft surveillance is advocated to monitor function; however, graft failure can occur between episodic examinations. An innovative sensor with wireless, microchip technology allows automated surveillance with assessment of graft function using a "cloud"-based algorithm. We performed proof-of-concept experiments with in vitro and in vivo models to assess the feasibility such a real-time graft surveillance system. METHODS: A self-monitoring graft system was evaluated consisting of a prosthetic conduit of expanded polytetrafluoroethylene and a sensor unit, and a microsensor, microelectronics, battery, and remote processor with a monitor. The sensor unit was integrated on the extraluminal surface of expanded polytetrafluoroethylene grafts without compromise to the lumen of the conduit. The grafts were tested in vitro in a pulsatile, recirculating flow system under physiologic flow parameters. The hemodynamic parameters were varied to assess the ability to obtain wireless signal acquisition reflecting real-time flow properties in vitro. Segments of custom tubing with reduced diameters were inserted into the model to mimic stenosis proximal and distal to the grafts. After characterization of the initial data, the self-monitoring grafts were implanted in an ovine carotid model to assess proof of concept in vivo with 30-day follow-up of signal acquisition as well as arteriographic and histologic analysis. RESULTS: In vitro flow data demonstrated the device was able to determine factors related to prosthetic graft function under varied hemodynamic flow conditions. Wireless signal acquisition using Bluetooth technology (Bluetooth SIG, Inc, Kirkland, Wash) allowed remote data analysis reflecting graft flow parameters through changes in microsensor voltage and frequency. Waveform analysis was applied to construct an algorithm using proprietary software and determine a parameter for graft flow characteristics. This algorithm allowed determination of the degree of stenosis and location of stenosis location (proximal or distal) for display on a remote monitor in real time. Subsequent in vivo experiments confirmed the ability of the system to generate signal acquisition through skin and soft tissue under biologic conditions with no arteriographic stenosis and a favorable healing response at 30-day harvest. CONCLUSIONS: Initial in vitro and in vivo experiments demonstrate the ability for a self-monitoring graft system to remotely monitor hemodynamic parameters reflecting graft function using wireless data transmission. This automated system shows promise to deliver real-time data that can be analyzed by cloud-based algorithms alerting the clinician of a change in graft function or development of stenosis for further diagnostic study or intervention before graft failure.


Subject(s)
Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Carotid Arteries/surgery , Hemodynamics , Remote Sensing Technology/instrumentation , Transducers , Algorithms , Animals , Blood Vessel Prosthesis Implantation/adverse effects , Carotid Arteries/pathology , Carotid Arteries/physiopathology , Cloud Computing , Feasibility Studies , Materials Testing , Miniaturization , Models, Animal , Polytetrafluoroethylene , Prosthesis Design , Sheep, Domestic , Signal Processing, Computer-Assisted , Time Factors , Wound Healing
5.
Philos Trans A Math Phys Eng Sci ; 370(1967): 2474-88, 2012 May 28.
Article in English | MEDLINE | ID: mdl-22509067

ABSTRACT

Field-effect transistors (FETs) are solid-state electrical devices featuring current sources, current drains and semiconductor channels through which charge carriers migrate. FETs can be inexpensive, detect analyte without label, exhibit exponential responses to surface potential changes mediated by analyte binding, require limited sample preparation and operate in real time. ImmunoFETs for protein sensing deploy bioaffinity elements on their channels (antibodies), analyte binding to which modulates immunoFET electrical properties. Historically, immunoFETs were assessed infeasible owing to ion shielding in physiological environments. We demonstrate reliable immunoFET sensing of chemokines by relatively ion-impermeable III-nitride immunoHFETs (heterojunction FETs) in physiological buffers. Data show that the specificity of detection follows the specificity of the antibodies used as receptors, allowing us to discriminate between individual highly related protein species (human and murine CXCL9) as well as mixed samples of analytes (native and biotinylated CXCL9). These capabilities demonstrate that immunoHFETs can be feasible, contrary to classical FET-sensing assessment. FET protein sensors may lead to point-of-care diagnostics that are faster and cheaper than immunoassay in clinical, biotechnological and environmental applications.


Subject(s)
Semiconductors , Animals , Antibody Specificity , Chemokine CXCL9/immunology , Feasibility Studies , Humans , Mice
6.
J R Soc Interface ; 6(37): 719-33, 2009 Aug 06.
Article in English | MEDLINE | ID: mdl-18986962

ABSTRACT

Proteins on biomicroelectromechanical systems (BioMEMS) confer specific molecular functionalities. In planar FET sensors (field-effect transistors, a class of devices whose protein-sensing capabilities we demonstrated in physiological buffers), interfacial proteins are analyte receptors, determining sensor molecular recognition specificity. Receptors are bound to the FET through a polymeric interface, and gross disruption of interfaces that removes a large percentage of receptors or inactivates large fractions of them diminishes sensor sensitivity. Sensitivity is also determined by the distance between the bound analyte and the semiconductor. Consequently, differential properties of surface polymers are design parameters for FET sensors. We compare thickness, surface roughness, adhesion, friction and wear properties of silane polymer layers bound to oxides (SiO(2) and Al(2)O(3), as on AlGaN HFETs). We compare those properties of the film-substrate pairs after an additional deposition of biotin and streptavidin. Adhesion between protein and device and interfacial friction properties affect FET reliability because these parameters affect wear resistance of interfaces to abrasive insult in vivo. Adhesion/friction determines the extent of stickage between the interface and tissue and interfacial resistance to mechanical damage. We document systematic, consistent differences in thickness and wear resistance of silane films that can be correlated with film chemistry and deposition procedures, providing guidance for rational interfacial design for planar AlGaN HFET sensors.


Subject(s)
Aluminum/chemistry , Nanostructures/chemistry , Proteins/chemistry , Silanes/chemistry , Silicon Dioxide/chemistry , Adhesiveness , Friction , Molecular Structure , Surface Properties , Transistors, Electronic
7.
Biosens Bioelectron ; 24(4): 505-11, 2008 Dec 01.
Article in English | MEDLINE | ID: mdl-18632260

ABSTRACT

Electrochemical detection of protein binding at physiological salt concentration by planar field effect transistor platforms has yet to be documented convincingly. Here we report detection of streptavidin and clinically relevant levels of biotinylated monokine induced by interferon gamma (MIG) at physiological salt concentrations with AlGaN heterojunction field effect transistors (HFETs). The AlGaN HFETs are functionalized with a silane linker and analyte-specific affinity elements. Polarity of sensor responses is as expected from n-type HFETs to negatively and positively charged analytes. Sensitivity of the HFET sensors increases when salt concentration decreases, and the devices also exhibit dose-dependent responses to analyte. Detection of clinically relevant MIG concentrations at physiological salt levels demonstrates the potential for AlGaN devices to be used in development of in vivo biosensors.


Subject(s)
Biosensing Techniques/instrumentation , Chemokine CXCL9/analysis , Electrochemistry/instrumentation , Immunoassay/instrumentation , Protein Interaction Mapping/instrumentation , Streptavidin/analysis , Transistors, Electronic , Biosensing Techniques/methods , Chemokine CXCL9/chemistry , Electrochemistry/methods , Equipment Design , Equipment Failure Analysis , Hydrogen-Ion Concentration , Immunoassay/methods , Microelectrodes , Protein Interaction Mapping/methods , Reproducibility of Results , Sensitivity and Specificity , Streptavidin/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...