1.
Indian J Endocrinol Metab ; 21(4): 600-617, 2017.
Article in English | MEDLINE | ID: mdl-28670547

ABSTRACT

Health-care professionals in India frequently manage injection or infusion therapies in persons with diabetes (PWD). Patients taking insulin should know the importance of proper needle size, correct injection process, complication avoidance, and all other aspects of injection technique from the first visit onward. To assist health-care practitioners in their clinical practice, Forum for Injection Technique and Therapy Expert Recommendations, India, has updated the practical advice and made it more comprehensive evidence-based best practice information. Adherence to these updated recommendations, learning, and translating them into clinical practice should lead to effective therapies, improved outcomes, and lower costs for PWD.

2.
Diabetes Ther ; 8(3): 659-672, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28289892

ABSTRACT

INTRODUCTION: Using the Indian and rest of world (ROW) injection technique questionnaire (ITQ) data, we address key insulin injection complications. METHODS: In 2015 we conducted an ITQ survey throughout India involving 1011 patients. Indian values were compared with those from 41 other countries participating in the ITQ, known here as ROW. RESULTS: More than a quarter of Indian insulin users described lesions consistent with lipohypertrophy (LH) at their injection sites and approximately 1 in 5 were found to have LH by the examining nurse (using visual inspection and palpation). Just over half of Indian injectors report having pain on injection. Of these, 4 out of 5 report having painful injections only several times a month or year (i.e., not with every injection). Doctors and diabetes educators in India (as opposed to nurses) have a larger role in teaching patients how to inject than they do in ROW. Despite this specialized approach, a very high percentage of patients report that they have not been trained (at least cannot remember being trained) in a wide range of essential injection topics. Only about 30% of Indian injectors get their sites checked at least annually, with nearly a third only having sites checked when they specifically complained and nearly 4 out of 10 never having had their sites checked. CONCLUSION: Indian HCPs can clearly do a better job covering all the vital topics essential to proper injection habits.

3.
Diabetes Ther ; 8(3): 637-657, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28289893

ABSTRACT

INTRODUCTION: It was estimated that 3.2 million Indians with diabetes injected insulin in 2010, but little is known about the techniques used. METHODS: In 2015 we conducted an injection technique questionnaire (ITQ) survey throughout India involving 1011 patients. Indian values were compared with those from 41 other countries participating in the ITQ, known here as rest of world (ROW). RESULTS: Mean HbA1c was 8.6. BMI values in India were 1.5-3 units lower than in ROW depending on patient group, meaning the risk of intramuscular (IM) injections is high in India. The mean total daily dose (TDD) of insulin was lower in every category of Indian patient than in ROW, perhaps reflecting the lower BMI. Needle reuse, whether with pens or syringes, is much higher in India than ROW and so is the number of times the needle is used. The majority (56.8%) of Indian insulin users performed only 2 injections/day as opposed to ROW where 45% of patients performed at least 4 injections/day. Indian patients inject insulin in the thighs more often than patients in ROW, a site where IM injections are more risky. Many patients do not have proper access to sharps containers or have other risk factors that could lead to blood-borne pathogen spread. More than 60% of used sharps in India go into the rubbish, with nearly 12% not even having the minimum protection of a cap. DISCUSSION: The shortest needles are very common in India; however, the level of needle reuse is high. Multiple daily injections therapy is not as common in India as ROW. More focus needs to be given to dwell times under the skin, reconstitution of cloudy insulins, skinfolds, and safe sharps disposal.