1.
J Clin Med ; 13(1)2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38202032

ABSTRACT

Introduction: Cranial CT scans are associated with radiation exposure to the eye lens, which is a particularly radiosensitive organ. Children are more vulnerable to radiation than adults. Therefore, it is essential to use the available dose reduction techniques to minimize radiation exposure. According to the European Consensus on patient contact shielding by the IRCP from 2021, shielding is not recommended in most body areas anymore. This study aims to evaluate whether bismuth shielding as well as its combination with other dose-saving technologies could still be useful. Methods: Cranial CT scans of a pediatric anthropomorphic phantom were performed on two up-to-date MDCT scanners. Eye lens dose measurements were performed using thermoluminescent dosimeters. Furthermore, the impact of BS and of the additional placement of standoff foam between the patient and BS on image quality was also assessed. Results: Bismuth shielding showed a significant lens dose reduction in both CT scanners (GE: 41.50 ± 4.04%, p < 0.001; Siemens: 29.75 ± 6.55%, p = 0.00). When combined with AEC, the dose was lowered even more (GE: 60.75 ± 3.30%, p < 0.001; Siemens: 41.25 ± 8.02%, p = 0.00). The highest eye dose reduction was achieved using BS + AEC + OBTCM (GE: 71.25 ± 2.98%, p < 0.001; Siemens: 58.75 ± 5.85%, p < 0.001). BS caused increased image noise in the orbital region, which could be mitigated by foam placement. Eye shielding had no effect on the image noise in the cranium. Conclusions: The use of BS in cranial CT can lead to a significant dose reduction, which can be further enhanced by its combination with other modern dose reduction methods. BS causes increase in image noise in the orbital region but not in the cranium. The additional use of standoff foam reduces image noise in the orbital region.

2.
J Thorac Imaging ; 37(5): 323-330, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35797627

ABSTRACT

PURPOSE: Computed tomography pulmonary angiography (CT-PA) is frequently used in the diagnostic workup of pulmonary embolism (PE), even in highly radiosensitive patient populations. This study aims to assess CT-PA with reduced z -axis coverage (compared with a standard scan range covering the entire lung) for its sensitivity for detecting PE and its potential to reduce the radiation dose. MATERIALS AND METHODS: We retrospectively analyzed 602 consecutive CT-PA scans with definite or possible PE reported. A reduced scan range was defined based on the topogram, where the cranial slice was set at the top of the aortic arch and the caudal slice at the top of the lower hemidiaphragm. Locations of emboli in relation to the reduced scan range were recorded. RESULTS: We included 513 CT-PA scans with definite acute PE in statistical analysis. Patients' median age was 66 (52 to 77) years, 46% were female. Median dose length product was 270.8 (111.3 to 503.9) mGy*cm. Comparing the original and reduced scan ranges, the mean scan length was significantly reduced by 48.0±8.6% (26.8±3.0 vs. 13.9±2.6 cm, P <0.001). Single emboli outside the reduced range in addition to emboli within were found in 15 scans (2.9%), while only 1 scan (0.2%) had an embolus outside the reduced range and none within it. The resulting sensitivity of CT-PA with reduced scan range was 99.81% (95% confidence interval: 98.74%-99.99%) for detecting any PE. CONCLUSION: A reduced scan length in CT-PA, as defined above, would substantially decrease radiation dose while maintaining diagnostic accuracy for detecting PE.


Subject(s)
Angiography , Pulmonary Embolism , Aged , Angiography/methods , Computed Tomography Angiography , Female , Humans , Lung , Male , Pulmonary Embolism/diagnostic imaging , Radiation Dosage , Retrospective Studies , Tomography, X-Ray Computed/methods
3.
PLoS One ; 12(6): e0178747, 2017.
Article in English | MEDLINE | ID: mdl-28570626

ABSTRACT

OBJECTIVES: To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. METHODS: Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. RESULTS: Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). CONCLUSIONS: Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications.


Subject(s)
Ankle/diagnostic imaging , Cone-Beam Computed Tomography/methods , Multidetector Computed Tomography/methods , Phantoms, Imaging , Radiation Dosage , Wrist/diagnostic imaging , Child , Humans
4.
Phys Med Biol ; 50(4): 643-54, 2005 Feb 21.
Article in English | MEDLINE | ID: mdl-15773625

ABSTRACT

A system for dosimetric verification of intensity-modulated radiotherapy (IMRT) treatment plans using absolute calibrated radiographic films is presented. At our institution this verification procedure is performed for all IMRT treatment plans prior to patient irradiation. Therefore clinical treatment plans are transferred to a phantom and recalculated. Composite treatment plans are irradiated to a single film. Film density to absolute dose conversion is performed automatically based on a single calibration film. A software application encompassing film calibration, 2D registration of measurement and calculated distributions, image fusion, and a number of visual and quantitative evaluation utilities was developed. The main topic of this paper is a performance analysis for this quality assurance procedure, with regard to the specification of tolerance levels for quantitative evaluations. Spatial and dosimetric precision and accuracy were determined for the entire procedure, comprising all possible sources of error. The overall dosimetric and spatial measurement uncertainties obtained thereby were 1.9% and 0.8 mm respectively. Based on these results, we specified 5% dose difference and 3 mm distance-to-agreement as our tolerance levels for patient-specific quality assurance for IMRT treatments.


Subject(s)
Equipment Failure Analysis/methods , Film Dosimetry/instrumentation , Quality Assurance, Health Care/methods , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Conformal/methods , Benchmarking/methods , Benchmarking/standards , Equipment Failure Analysis/standards , Film Dosimetry/methods , Film Dosimetry/standards , Quality Assurance, Health Care/standards , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/standards , Reproducibility of Results , Sensitivity and Specificity
5.
Phys Med Biol ; 48(9): 1123-32, 2003 May 07.
Article in English | MEDLINE | ID: mdl-12765326

ABSTRACT

Mechanical stability and precise adjustment of rotation axes, collimator and room lasers are essential for the success of radiotherapy and particularly stereotactic radiosurgery with a linear accelerator. Quality assurance procedures, at present mainly based on visual tests and radiographic film evaluations, should desirably be little time consuming and highly accurate. We present a method based on segmentation and analysis of digital images acquired with an electronic portal imaging device (EPID) that meets these objectives. The method can be employed for routine quality assurance with a square field formed by the built-in collimator jaws as well as with a circular field using an external drill hole collimator. A number of tests, performed to evaluate accuracy and reproducibility of the algorithm, yielded very satisfying results. Studies performed over a period of 18 months prove the applicability of the inspected accelerator for stereotactic radiosurgery.


Subject(s)
Algorithms , Particle Accelerators/instrumentation , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/instrumentation , Robotics/methods , Calibration , Equipment Design , Equipment Failure Analysis , Feedback , Lasers , Particle Accelerators/standards , Quality Control , Radiographic Image Enhancement/instrumentation , Radiographic Image Enhancement/methods , Radiotherapy/methods , Radiotherapy/standards , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Reproducibility of Results , Rotation , Sensitivity and Specificity
6.
Breast J ; 8(5): 320-2, 2002.
Article in English | MEDLINE | ID: mdl-12199765

ABSTRACT

A case of radiation-induced sarcoma of the chest wall is reported. Twenty-seven years 11 months after orthovoltage radiotherapy of the right breast a 69-year-old woman developed a radiation-induced osteosarcoma of the right thoracic wall. Initial diagnosis has been T-cell lymphoma of the skin. The right breast was irradiated with tangential fields and a total dose of 40 Gy, 2 Gy/day, 5 days a week. Orthovoltage treatment was performed in two courses of 20 Gy, 3 months apart. The clinical appearance of the secondary sarcoma was a diffuse infiltrated area in the irradiated breast which seemed to be fixed to the chest wall. Magnetic resonance imaging (MRI) demonstrated a mass in the right anterior thoracic wall which destroyed the fourth to the sixth rib. The tumor infiltrated the thoracic wall, including subcutaneous tissue and pericardium, as well as extending into the subphrenic space. Biopsy of the lesion revealed a poorly differentiated osteosarcoma. The patient's general condition precluded surgical or chemotherapeutic intervention; she died due to a cerebral stroke 6 months later. This case fulfilled all criteria for radiation-induced sarcoma, as there was a prior history of radiotherapy, latency period of several years, development of sarcoma within the irradiated field, and histologic confirmation of sarcoma.


Subject(s)
Bone Neoplasms/diagnosis , Breast Neoplasms/radiotherapy , Lymphoma, T-Cell/radiotherapy , Neoplasms, Radiation-Induced/diagnosis , Osteosarcoma/diagnosis , Aged , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/pathology , Diagnosis, Differential , Fatal Outcome , Female , Humans , Magnetic Resonance Imaging , Neoplasms, Radiation-Induced/diagnostic imaging , Neoplasms, Radiation-Induced/pathology , Osteosarcoma/diagnostic imaging , Osteosarcoma/pathology , Radionuclide Imaging , Thoracic Wall , Tomography, X-Ray Computed