Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurosci Methods ; 373: 109561, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35301006

ABSTRACT

BACKGROUND: Intracranial hypertension (HI) is associated with worse neurological outcomes and higher mortality. Although there are several experimental models of HI, in this article we present a reproducible, reversible, and reliable model of intracranial hypertension, with continuous multimodal monitoring. NEW METHOD: A reversible intracranial hypertension model in swine with multimodal monitoring including intracranial pressure, arterial blood pressure, heart rate variation, brain tissue oxygenation, and electroencephalogram is developed to understand the relationship of ICP and EEG. By inflating and deflating a balloon, located 20 mm anterior to the coronal suture and a 15 mm sagittal suture, we generate intracranial hypertension events and simultaneously measure intracranial pressure and oxygenation in the contralateral hemisphere and the EEG, simulating the usual configuration in humans. RESULTS: We completed 5 experiments and in all of them, we were able to complete at least 6 events of intracranial hypertension in a stable and safe way. For events of 20-40 mmHg of ICP we need an median (IQR) of 4.2 (3.64) ml of saline solution into the Foley balloon, a median (IQR) infusion time of 226 (185) second in each event and for events of 40-50 mmHg of ICP we need a median (IQR) of 5.1 (4.66) ml of saline solution, a median (IQR) infusion time of 280 (48) seconds and a median (IQR). The median (IQR) maintenance time was 352 (77) seconds and 392 (166) seconds for 20-40 mmHg and 40-50 mmHg of ICP, respectively. COMPARISON WITH EXISTING METHOD(S): Existing methods do not include EEG measures and do not present the reversibility of intracranial hypertension. CONCLUSIONS: Our model is fully reproducible, it is capable of generating reversible focal intracranial hypertension through strict control of the injected volume, it is possible to generate different infusion rates of the volume in the balloon, in order to generate different scenarios, the data obtained are sufficient to determine the brain complacency in real time. and useful for understanding the pathophysiology of ICP and the relationship between ICP (CPP) and EEG.


Subject(s)
Intracranial Hypertension , Animals , Brain , Electroencephalography , Heart Rate , Intracranial Hypertension/etiology , Intracranial Pressure/physiology , Swine
2.
Korean J Anesthesiol ; 75(1): 86-96, 2022 02.
Article in English | MEDLINE | ID: mdl-34674515

ABSTRACT

BACKGROUND: To detect an early increase in the inflammatory response might prove to be vital for mitigating the deleterious effects of the disease over time. CASES: A 52-year-old obese man with moderate asthma and hypertension, who developed COVID-19 and had moderate symptoms, used a wearable device to record heart rate variability (HRV) during his illness. He had low parasympathetic tone, which decreased daily until it reached almost 2 standard deviations (SD) below normal values at the end of the second week. His sympathetic tone increased from > 3 SD to > 5 SD. CONCLUSIONS: Conclusions: These findings suggest an altered modulation of the sympathetic and parasympathetic nervous systems in COVID-19, such that the sympathetic tone is augmented and the parasympathetic tone is reduced. Population norms of COVID-19 infections should be further studied over the short-term and using 24 h HRV measurements.


Subject(s)
COVID-19 , Wearable Electronic Devices , Follow-Up Studies , Heart Rate , Humans , Male , Middle Aged , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...