1.
Expert Rev Mol Diagn ; 21(3): 333-342, 2021 03.
Article in English | MEDLINE | ID: mdl-33849372

ABSTRACT

Background: Here we compare the performance of the high-throughput BD COR System (COR) to the Viper LT System (Viper) using the BD Onclarity HPV assay.Research Design and Methods: Remnant clinical specimens, contrived specimens in SurePath (BD) and PreservCyt (Hologic) media, and prospective clinical specimens in BD Cervical Brush Diluent (CBD) were tested. Outcomes included intra-laboratory agreement of Onclarity results on COR and inter-system agreement between COR and Viper.Results: Onclarity reproducibility on COR resulted in standard deviation and correlation of variation of Ct values ranging from 0.14 to 1.98 and 0.49% to 2.15%, respectively, for contrived specimens, and 0.9-3.08 and 2.89-9.21%, respectively, for clinical specimens. In the COR and Viper clinical agreement study, OPA for Onclarity ranged from 97.1%-98.9%, depending on the collection media type. PPA values for pooled, HPV(+) specimens at low positive (C95), and moderate positive (3XC95) target concentrations were ≥95.0% and 100%, respectively; PPA values associated with HPV 16, 18, 31, 45, 33/58, 52, 35/39/68, 51, and 56/59/66, individually, ranged from 93.8%-100%.Conclusions: Onclarity performance on COR is equivalent to Viper, and is accurate and reproducible for detection of all high-risk HPV genotypes, with a throughput of 330 results from a single 8-hour shift.


Subject(s)
Papillomavirus Infections , Uterine Cervical Neoplasms , Female , Humans , Papillomaviridae/genetics , Papillomavirus Infections/diagnosis , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Uterine Cervical Neoplasms/diagnosis
2.
Am J Clin Pathol ; 142(1): 43-50, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24926084

ABSTRACT

OBJECTIVES: To compare the performance of the BD Onclarity HPV Assay (BD Diagnostics, Sparks, MD) in BD SurePath liquid-based cytology media with that of Hybrid Capture 2 (HC2, Qiagen, Germantown, MD) samples co-collected in specimen transport medium in an adjudicated patient cohort. METHODS: The performance of the BD Onclarity HPV Assay using BD SurePath media was compared with that of HC2 samples co-collected in specimen transport medium using 541 archived samples from a multicenter US clinical trial with histologically adjudicated cervical biopsy specimens. RESULTS: The sensitivity for cervical intraepithelial neoplasia (CIN) 2 positivity (n - 104) was 90.4% (95% confidence interval [CI], 83-95) and 93.3% (95% CI, 87-97) and specificity was 76.9% (95% CI, 73-81) and 77.8% (95% CI, 74-82) for the BD assay and HC2, respectively. Nine cases of CIN 2+ had results discordant with the high-risk HPV assay. All were found to have been correctly classified with the BD assay using a novel WAVE denaturing high-performance liquid chromatography double-stranded DNA sequencing method. CONCLUSIONS: The clinical performance of The BD Onclarity HPV Assay with respect to histology end points was similar to HC2. Moreover, discordant analysis revealed improved performance of the BD assay with respect to ability to provide extended genotyping information and lack of cross-reactivity with low-risk HPV types associated with cellular abnormalities. The relative risks for CIN 3 disease for HPV 31 and HPV 33/58 (combined) were comparable to that of HPV 18 in this population, suggesting that these genotypes may warrant monitoring in future studies.


Subject(s)
Cervix Uteri/virology , Papillomaviridae/isolation & purification , Papillomavirus Infections/diagnosis , Reagent Kits, Diagnostic/standards , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Neoplasms/diagnosis , Adult , DNA, Viral/analysis , DNA, Viral/genetics , Female , Humans , Papillomaviridae/genetics , Papillomavirus Infections/virology , Pregnancy , Sensitivity and Specificity , Uterine Cervical Neoplasms/virology , Uterine Cervical Dysplasia/virology
3.
J Clin Microbiol ; 51(8): 2702-6, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23678069

ABSTRACT

We evaluated the effect of storage at 2 to 8°C on the stability of human genomic and human papillomavirus (HPV) DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media. DNA retained the ability to be extracted and PCR amplified for more than 2.5 years in both medium types. Prior inability to detect DNA in archived specimens may have been due to failure of the extraction method to isolate DNA from fixed cells.


Subject(s)
Cytological Techniques/methods , DNA, Viral/isolation & purification , Papillomaviridae/isolation & purification , Specimen Handling/methods , Virology/methods , Culture Media/chemistry , DNA, Viral/genetics , Humans , Papillomaviridae/genetics , Refrigeration , Time Factors
4.
J Clin Microbiol ; 49(8): 3029-32, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21632892

ABSTRACT

Using archived specimens, we evaluated a new automated real-time PCR assay (BD Diagnostics) that detects all carcinogenic human papillomaviruses (HPV) and provides HPV genotyping for seven of them, including HPV16 and HPV18, the two most carcinogenic HPV genotypes. We found comparable results with Hybrid Capture 2 (HC2) for detection of carcinogenic HPV (n = 473) and with Linear Array and Line Blot Assay (n = 371) for detection of individual HPV genotypes.


Subject(s)
Molecular Diagnostic Techniques/methods , Papillomaviridae/classification , Papillomaviridae/isolation & purification , Papillomavirus Infections/virology , Real-Time Polymerase Chain Reaction/methods , Virology/methods , Adult , DNA, Viral/genetics , Female , Genotype , Humans , Papillomaviridae/genetics , Papillomaviridae/pathogenicity
SELECTION OF CITATIONS
SEARCH DETAIL