Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
1.
Clin Orthop Relat Res ; 481(8): 1464-1470, 2023 08 01.
Article in English | MEDLINE | ID: mdl-36853879

ABSTRACT

BACKGROUND: The severity of glenohumeral osteoarthritis (OA) as demonstrated by preoperative radiographs and patient-reported pain plays an important role in the indication for anatomic total shoulder arthroplasty (aTSA). In hip and knee research, data about the effect of the severity of preoperative radiographic OA on the outcome of total joint arthroplasty have been mixed. For shoulder replacement, we are unsure of the effects of radiographic severity on outcomes. QUESTIONS/PURPOSES: This study investigated whether the preoperative radiographic severity of glenohumeral OA is associated with improvement in pain and function after aTSA. We asked, (1) does the severity of glenohumeral OA correlate with improvement in patient-reported outcomes after TSA (delta American Shoulder and Elbow Surgeons score [postoperative-preoperative], delta Single Assessment Numeric Evaluation, delta Simple Shoulder Test, and delta VAS)? (2) Is having mild osteoarthritis associated with not meeting the minimum clinically important differences in preoperative and postoperative American Shoulder and Elbow Surgeons scores? METHODS: An institutional query of patients who underwent aTSA for OA was performed between January 2015 and December 2018. A total of 1035 patients were eligible; however, only patients with adequate preoperative radiographs and patient-reported outcome measures collected preoperatively and at a minimum of 2 years postoperatively were included. Patients with proximal humerus fractures, inflammatory arthropathy, cuff tear arthropathy, prior ipsilateral rotator cuff repair, brachial plexus injury or neuromuscular disorder, workers compensation, periprosthetic joint infection, or revision surgery within 2 years were excluded. Patient characteristics, comorbidities, and prior shoulder surgery were recorded. The severity of OA was classified based on the modified Samilson-Prieto and Walch classification. The association between Samilson-Prieto grade and patient-reported outcome measures (American Shoulder and Elbow Surgeons Score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and VAS score) was evaluated. Radiographic characteristics, patient demographics, comorbidities, and prior surgery were also evaluated for the potential risk of not achieving improvement in the minimum clinically important difference (16.1) with respect to the American Shoulder and Elbow Surgeons score. The American Shoulder and Elbow Surgeons score is scored 0 to 100, with higher scores representing less pain and better function. A total of 206 patients (20% of those eligible) with a mean follow-up of 2.3 years were included. Twenty-three patients had Samilson-Prieto Grade I, 38 had Grade II, 57 had Grade III, and 88 had Grade IV. RESULTS: There were no differences in improvements (delta) between the groups and between patient-reported outcome scores (American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and VAS). Compared with patients with more severe osteoarthritis (Samilson-Prieto Grades II, III, and IV), a higher proportion of patients with less severe osteoarthritis (Grade I) did not exceed the minimum clinical important difference for the American Shoulder and Elbow Surgeons score (22% [five of 23] versus 4% [seven of 183]; odds ratio 0.14 [95% confidence interval 0.04 to 0.520]; p = 0.006). CONCLUSION: The improvement in patient-reported outcome measure scores was similar regardless of radiographic severity after aTSA. Surgeons should use caution when recommending surgery to patients with less severe OA because a higher percentage did not improve, based on the minimum clinically important difference. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Arthroplasty, Replacement, Shoulder , Osteoarthritis , Rotator Cuff Tear Arthropathy , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/adverse effects , Arthroplasty, Replacement, Shoulder/methods , Treatment Outcome , Osteoarthritis/diagnostic imaging , Osteoarthritis/surgery , Osteoarthritis/complications , Pain , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Retrospective Studies , Range of Motion, Articular
2.
Radiology ; 295(2): 307-313, 2020 05.
Article in English | MEDLINE | ID: mdl-32125255

ABSTRACT

Background The risks associated with MRI in individuals who have implanted cardiac devices are thought to arise from the interaction between the implanted device and static, gradient, and radiofrequency magnetic fields. Purpose To determine the relationship between the peak whole-body averaged specific absorption rate (SAR) and change in magnetic field per unit time (dB/dt), maximum specific energy dose, imaging region, and implanted cardiac device characteristics and their function in patients undergoing MRI. Materials and Methods This prospective observational cohort study was conducted from October 16, 2003, to January 22, 2015 (https://ClinicalTrials.gov, NCT01130896). Any individual with an implanted cardiac device who was referred for MRI was included. Clinical MRI protocols without SAR restriction were used. Exclusion criteria were newly implanted leads, abandoned or epicardial leads, and dependence on a pacemaker with an implantable cardioverter defibrillator without asynchronous pacing capability. For each MRI pulse sequence, the calculated whole-body values for SAR, dB/dt, and scan duration were collected. Atrial and ventricular sensing, lead impedance, and capture threshold were evaluated before and immediately after (within 10 minutes) completion of each MRI examination. Generalized estimating equations with Gaussian family, identity link, and an exchangeable working correlation matrix were used for statistical analysis. Results A total of 2028 MRI examinations were performed in 1464 study participants with 2755 device leads (mean age, 67 years ± 15 [standard deviation]; 930 men [64%]). There was no evidence of an association between radiofrequency energy deposition, dB/dt, or scan duration and changes in device parameters. Thoracic MRI was associated with decreased battery voltage immediately after MRI (ß = -0.008 V, P < .001). Additionally, right ventricular (RV) lead length was associated with decreased RV sensing (ß = -0.012 mV, P = .05) and reduced RV capture threshold (ß = -0.002 V, P < .01) immediately after MRI. Conclusion There was no evidence of an association between MRI parameters that characterize patient exposure to radiofrequency energy and changes in device and lead parameters immediately after MRI. Nevertheless, device interrogation before and after MRI remains mandatory due to the potential for device reset and changes in lead or generator parameters. © RSNA, 2020 See also the editorial by Shellock in this issue.


Subject(s)
Defibrillators, Implantable , Magnetic Resonance Imaging/methods , Pacemaker, Artificial , Patient Safety , Aged , Clinical Protocols , Equipment Safety , Female , Humans , Male , Prospective Studies , Radio Waves
3.
IEEE Trans Biomed Eng ; 67(6): 1616-1627, 2020 06.
Article in English | MEDLINE | ID: mdl-31535979

ABSTRACT

OBJECTIVE: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Animals , Catheters , Electrophysiology , Equipment Design , Phantoms, Imaging , Swine
4.
Magn Reson Med ; 83(4): 1368-1379, 2020 04.
Article in English | MEDLINE | ID: mdl-31565818

ABSTRACT

PURPOSE: To evaluate non-contrast-enhanced MRI of acute radio-frequency ablation (RFA) lesions in the left atrium (LA) and pulmonary vein (PV) ostia. The goal is to provide a method for discrimination between necrotic (permanent) lesions and reversible injury, which is associated with recurrence after treatment of atrial fibrillation. METHODS: Fifteen normal swine underwent RFA around the right-superior PV ostia. Electrical pulmonary vein isolation (PVI) was verified by electro-anatomic mapping (EAM) and pacing. MRI was carried out using a 3D respiratory-gated T1 -weighted long inversion time (TWILITE) sequence without contrast agent. Key settings were: inversion time 700 ms, triggering over 2 cardiac cycles, pixel size 1.1 mm3 . Contrast-enhanced imaging and T2 -weighted imaging were carried out for comparison. Six animals were sacrificed on ablation day for TTC-stained gross pathology, 9 animals were sacrificed after 2-3 mo after repeat EAM and MRI. Image intensity ratio (IIR) was used to measure lesion enhancement, and gross pathology was used to validate image enhancement patterns and compare lesion widths. RESULTS: RFA lesions exhibited unambiguous enhancement in acute TWILITE imaging (IIR = 2.34 ± 0.49 at 1.5T), and the enhancement patterns corresponded well with gross pathology. Lesion widths in MRI correlated well with gross pathology (R2 = 0.84), with slight underestimation by 0.9 ± 0.5 mm. Lesion enhancement subsided chronically. CONCLUSION: TWILITE imaging allowed acute detection of permanent RFA lesions in swine LA and PV ostia, without the need for contrast agent. Lesion enhancement pattern showed good correspondence to gross pathology and was well visualized by volume rendering. This method may provide valuable intra- or post-procedural assessment of RFA treatment.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Animals , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Magnetic Resonance Imaging , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Swine
5.
Magn Reson Imaging ; 64: 132-141, 2019 12.
Article in English | MEDLINE | ID: mdl-31247254

ABSTRACT

Magnetic resonance (MR) images with both high resolutions and high signal-to-noise ratios (SNRs) are desired in many clinical and research applications. However, acquiring such images takes a long time, which is both costly and susceptible to motion artifacts. Acquiring MR images with good in-plane resolution and poor through-plane resolution is a common strategy that saves imaging time, preserves SNR, and provides one viewpoint with good resolution in two directions. Unfortunately, this strategy also creates orthogonal viewpoints that have poor resolution in one direction and, for 2D MR acquisition protocols, also creates aliasing artifacts. A deep learning approach called SMORE that carries out both anti-aliasing and super-resolution on these types of acquisitions using no external atlas or exemplars has been previously reported but not extensively validated. This paper reviews the SMORE algorithm and then demonstrates its performance in four applications with the goal to demonstrate its potential for use in both research and clinical scenarios. It is first shown to improve the visualization of brain white matter lesions in FLAIR images acquired from multiple sclerosis patients. Then it is shown to improve the visualization of scarring in cardiac left ventricular remodeling after myocardial infarction. Third, its performance on multi-view images of the tongue is demonstrated and finally it is shown to improve performance in parcellation of the brain ventricular system. Both visual and selected quantitative metrics of resolution enhancement are demonstrated.


Subject(s)
Hydrocephalus, Normal Pressure/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Tongue Neoplasms/diagnostic imaging , Algorithms , Artifacts , Brain/diagnostic imaging , Deep Learning , Heart Ventricles/diagnostic imaging , Humans , Motion , Signal-To-Noise Ratio , Tongue/diagnostic imaging
6.
JACC Clin Electrophysiol ; 5(1): 91-100, 2019 01.
Article in English | MEDLINE | ID: mdl-30678791

ABSTRACT

OBJECTIVES: This study examined radiofrequency catheter ablation (RFCA) lesions within and around scar by cardiac magnetic resonance (CMR) imaging and histology. BACKGROUND: Substrate modification by RFCA is the cornerstone therapy for ventricular arrhythmias. RFCA in scarred myocardium, however, is not well understood. METHODS: We performed electroanatomic mapping and RFCA in the left ventricles of 8 swine with myocardial infarction. Non-contrast-enhanced T1-weighted (T1w) and contrast-enhanced CMR after RFCA were compared with gross pathology and histology. RESULTS: Of 59 lesions, 17 were in normal myocardium (voltage >1.5 mV), 21 in border zone (0.5 to 1.5 mV), and 21 in scar (<0.5 mV). All RFCA lesions were enhanced in T1w CMR, whereas scar was hypointense, allowing discrimination among normal myocardium, scar, and RFCA lesions. With contrast-enhancement, lesions and scar were similarly enhanced and not distinguishable. Lesion width and depth in T1w CMR correlated with necrosis in pathology (both; r2 = 0.94, p < 0.001). CMR lesion volume was significantly different in normal myocardium, border zone, and scar (median: 397 [interquartile range (IQR): 301 to 474] mm3, 121 [IQR: 87 to 201] mm3, 66 [IQR: 33 to 123] mm3, respectively). RFCA force-time integral, impedance, and voltage changes did not correlate with lesion volume in border zone or scar. Histology showed that ablation necrosis extended into fibrotic tissue in 26 lesions and beyond in 14 lesions. In 7 lesions, necrosis expansion was blocked and redirected by fat. CONCLUSIONS: T1w CMR can selectively enhance necrotic tissue in and around scar and may allow determination of the completeness of ablation intra- and post-procedure. Lesion formation in scar is affected by tissue characteristics, with fibrosis and fat acting as thermal insulators.


Subject(s)
Catheter Ablation , Cicatrix , Electrophysiologic Techniques, Cardiac/methods , Heart Ventricles , Magnetic Resonance Imaging/methods , Animals , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/surgery , Cardiac Imaging Techniques/methods , Cicatrix/diagnostic imaging , Cicatrix/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Myocardial Infarction/physiopathology , Myocardial Infarction/surgery , Swine
7.
J Cardiovasc Comput Tomogr ; 12(5): 372-378, 2018.
Article in English | MEDLINE | ID: mdl-29784623

ABSTRACT

BACKGROUND: CT SQUEEZ is a new automated technique to evaluate regional endocardial strain by tracking features on the endocardium from 4D cine CT data. The objective of this study was to measure the range of endocardial regional strain (RSCT) values obtained with CT SQUEEZ in the normal human left ventricle (LV) from standard clinical 4D coronary CTA exams. METHODS: RSCT was measured over the heart cycle in 25 humans with normal LV function using cine CT from three vendors. Mean and standard deviation of RSCT values were computed in 16 AHA LV segments to estimate the range of values expected in the normal LV. RESULTS: Curves describing RSCT vs. time were consistent between subjects. There was a slight gradient of decreasing minimum RSCT value (increased shortening) from the base to the apex of the heart. Mean RSCT values at end-systole were: base = -32% ± 1%, mid = -33% ± 1%, apex = -36% ± 1%. The standard deviation of the minimum systolic RSCT in each segment over all subjects was 5%. The average time to reach maximum shortening was 34% of the RR interval. CONCLUSIONS: Regional strain (RSCT) can be rapidly obtained from standard gated coronary CCTA protocols using 4DCT SQUEEZ processing. We estimate that 95% of normal LV end-systolic RSCT values will fall between -23% and -43%; therefore, we hypothesize that an RSCT value higher than -23% will indicate a hypokinetic segment in the human heart.


Subject(s)
Cineangiography , Computed Tomography Angiography , Coronary Angiography/methods , Four-Dimensional Computed Tomography , Heart Ventricles/diagnostic imaging , Myocardial Contraction , Ventricular Function, Left , Biomechanical Phenomena , Humans , Predictive Value of Tests , Preliminary Data , Radiographic Image Interpretation, Computer-Assisted , Reference Values , Reproducibility of Results , Stress, Mechanical
8.
Magn Reson Med ; 79(2): 879-889, 2018 02.
Article in English | MEDLINE | ID: mdl-28497622

ABSTRACT

PURPOSE: To demonstrate imaging of radiofrequency ablation lesions with non-contrast-enhanced T1 -weighted (T1w) MRI. METHODS: Fifteen swine underwent left ventricular ablation followed by MRI using different preparations: endocardial or epicardial ablation of naïve animal, or endocardial ablation of animal with myocardial infarction. Lesion imaging was performed using free-breathing, non-contrast-enhanced, T1w sequence with long inversion time (TI). Also acquired were T1 maps and delayed contrast-enhanced (DCE) imaging. Hearts were excised for ex vivo imaging, and sliced for gross pathology and histology. RESULTS: All ablations were visibly enhanced in non-contrast-enhanced T1w imaging using TI = 700 ms. T1w enhancement agreed with regions of necrosis in gross pathology and histology. Enhanced lesion cores were surrounded by dark bands containing contraction band necrosis, hematoma, and edema. In animals with myocardial infarction, chronic scar was hypointense in T1w, whereas acute ablations were enhanced, allowing discrimination between chronic scar and acute lesions, unlike DCE. Contrast was sufficient to create 3D volume renderings of lesions after minor postprocessing. CONCLUSIONS: Non-contrast-enhanced T1w imaging with long TI promises to be an effective method for visualizing necrosis within radiofrequency ablation lesions. Enhancement is more specific and stationary than that from DCE. The imaging can be repeated as needed, unlike DCE, and may be especially useful for assessing ablations during or after a procedure. Magn Reson Med 79:879-889, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Magnetic Resonance Imaging/methods , Postoperative Complications/diagnostic imaging , Radiofrequency Ablation/adverse effects , Animals , Computer Simulation , Heart Ventricles/pathology , Pericardium/diagnostic imaging , Pericardium/pathology , Postoperative Complications/pathology , Swine
9.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Article in English | MEDLINE | ID: mdl-27729363

ABSTRACT

BACKGROUND: Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. METHODS AND RESULTS: A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. CONCLUSIONS: A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures.


Subject(s)
Defibrillators , Electric Countershock/instrumentation , Heart Arrest/therapy , Magnetic Resonance Imaging/adverse effects , Resuscitation/instrumentation , Time-to-Treatment , Animals , Disease Models, Animal , Equipment Design , Heart Arrest/diagnostic imaging , Heart Arrest/etiology , Heart Arrest/physiopathology , Humans , Magnetic Resonance Imaging/instrumentation , Materials Testing , Sus scrofa
10.
J Biomech Eng ; 135(4): 044501, 2013 Apr.
Article in English | MEDLINE | ID: mdl-24231903

ABSTRACT

Moment arms represent a muscle's ability to generate a moment about a joint for a given muscle force. The goal of this study was to develop a method to measure muscle moment arms in vivo over a large range of motion using real-time magnetic resonance (MR) imaging. Rectus femoris muscle-tendon lengths and knee joint angles of healthy subjects (N = 4) were measured during dynamic knee joint flexion and extension in a large-bore magnetic resonance imaging (MRI) scanner. Muscle-tendon moment arms were determined at the knee using the tendon-excursion method by differentiating measured muscle-tendon length with respect to joint angle. Rectus femoris moment arms were averaged across a group of healthy subjects and were found to vary similarly during knee joint flexion (mean: 3.0 (SD 0.5) cm, maximum: 3.5 cm) and extension (mean: 2.8 (SD 0.4) cm, maximum: 3.6 cm). These moment arms compare favorably with previously published dynamic tendon-excursion measurements in cadaveric specimens but were relatively smaller than moment arms from center-of-rotation studies. The method presented here provides a new approach to measure muscle-tendon moment arms in vivo and has the potential to be a powerful resource for characterizing musculoskeletal geometry during dynamic joint motion.


Subject(s)
Knee/physiology , Magnetic Resonance Imaging , Movement , Quadriceps Muscle/physiology , Adult , Female , Humans , Range of Motion, Articular , Time Factors
11.
J Nucl Med ; 51 Suppl 1: 38S-50S, 2010 May 01.
Article in English | MEDLINE | ID: mdl-20457794

ABSTRACT

Cardiovascular molecular imaging is a new discipline that integrates scientific advances in both functional imaging and molecular probes to improve our understanding of the molecular basis of the cardiovascular system. These advances are driven by in vivo imaging of molecular processes in animals, usually small animals, and are rapidly moving toward clinical applications. Molecular imaging has the potential to revolutionize the diagnosis and treatment of cardiovascular disease. The 2 key components of all molecular imaging systems are the molecular contrast agents and the imaging system providing spatial and temporal localization of these agents within the body. They must deliver images with the appropriate sensitivity and specificity to drive clinical applications. As work in molecular contrast agents matures and highly sensitive and specific probes are developed, these systems will provide the imaging technologies required for translation into clinical tools. This is the promise of molecular medicine.


Subject(s)
Cardiovascular Diseases/diagnosis , Cardiovascular System/pathology , Acoustics , Animals , Cardiovascular Diseases/pathology , Computer Graphics , Contrast Media/pharmacology , Diagnostic Imaging/methods , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/methods , Models, Biological , Tomography, Optical/methods , Ultrasonography/methods , User-Computer Interface
12.
Magn Reson Med ; 63(4): 1070-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20373408

ABSTRACT

The accurate visualization of interventional devices is crucial for the safety and effectiveness of MRI-guided interventional procedures. In this paper, we introduce an improvement to the visualization of active devices. The key component is a fast, robust method ("CurveFind") that reconstructs the three-dimensional trajectory of the device from projection images in a fraction of a second. CurveFind is an iterative prediction-correction algorithm that acts on a product of orthogonal projection images. By varying step size and search direction, it is robust to signal inhomogeneities. At the touch of a key, the imaged slice is repositioned to contain the relevant section of the device ("SnapTo"), the curve of the device is plotted in a three-dimensional display, and the point on a target slice, which the device will intersect, is displayed. These features have been incorporated into a real-time MRI system. Experiments in vitro and in vivo (in a pig) have produced successful results using a variety of single- and multichannel devices designed to produce both spatially continuous and discrete signals. CurveFind is typically able to reconstruct the device curve, with an average error of approximately 2 mm, even in the case of complex geometries.


Subject(s)
Algorithms , Image Enhancement/instrumentation , Magnetic Resonance Imaging, Interventional/instrumentation , Animals , Biopsy, Needle/instrumentation , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Phantoms, Imaging , Swine , Vascular Diseases/surgery
13.
J Magn Reson Imaging ; 31(4): 1015-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20373448

ABSTRACT

PURPOSE: To enhance real-time magnetic resonance (MR)-guided catheter navigation by overlaying colorized multiphase MR angiography (MRA) and cholangiopancreatography (MRCP) roadmaps in an anatomic context. MATERIALS AND METHODS: Time-resolved MRA and respiratory-gated MRCP were acquired prior to real-time imaging in a pig model. MRA and MRCP data were loaded into a custom real-time MRI reconstruction and visualization workstation where they were displayed as maximum intensity projections (MIPs) in distinct colors. The MIPs were rendered in 3D together with real-time multislice imaging data using alpha blending. Interactive rotation allowed different views of the combined data. RESULTS: Fused display of the previously acquired MIP angiography data with real-time imaging added anatomical context during endovascular interventions in swine. The use of multiple MIPs rendered in different colors facilitated differentiation of vascular structures, improving visual feedback during device navigation. CONCLUSION: Interventional real-time MRI may be enhanced by combining with previously acquired multiphase angiograms. Rendered as 3D MIPs together with 2D slice data, this technique provided useful anatomical context that enhanced MRI-guided interventional applications.


Subject(s)
Cholangiopancreatography, Magnetic Resonance/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging, Interventional/methods , Magnetic Resonance Imaging/methods , Animals , Image Processing, Computer-Assisted/methods , Lung/pathology , Models, Anatomic , Swine , Thrombectomy/methods , Time Factors
14.
J Thorac Cardiovasc Surg ; 139(2): 424-30, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19969312

ABSTRACT

OBJECTIVE: Percutaneous valve replacements are presently being evaluated in clinical trials. As delivery of the valve is catheter based, the safety and efficacy of these procedures may be influenced by the imaging used. To assist the surgeon and improve the success of the operation, we have performed transapical aortic valve replacements using real-time magnetic resonance imaging guidance. METHODS: Twenty-eight swine underwent aortic valve replacement by real-time magnetic resonance imaging on the beating heart. Stentless bioprostheses mounted on balloon-expandable stents were used. Magnetic resonance imaging (1.5 T) was used to identify the critical anatomic landmarks. In addition to anatomic confirmation of adequate placement of the prosthesis, functional assessment of the valve and left ventricle and perfusion were also obtained with magnetic resonance imaging. A series of short-term feasibility experiments were conducted (n = 18) in which the animals were humanely killed after valve placement and assessment by magnetic resonance imaging. Ten additional animals were allowed to survive and had follow-up magnetic resonance imaging scans and confirmatory echocardiography at 1, 3, and 6 months postoperatively. RESULTS: Real-time magnetic resonance imaging provided superior visualization of the landmarks needed. The time to implantation after apical access was 74 +/- 18 seconds. Perfusion scanning demonstrated adequate coronary flow and functional imaging documented preservation of ventricular contractility in all animals after successful deployment. Phase contrast imaging revealed minimal intravalvular or paravalvular leaks. Longer term results demonstrated stability of the implants with preservation of myocardial perfusion and function over time. CONCLUSIONS: Real-time magnetic resonance imaging provides excellent visualization for intraoperative guidance of aortic valve replacement on the beating heart. Additionally, it allows assessment of tissue perfusion and organ function that is not obtainable by conventional imaging alone.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Magnetic Resonance Imaging , Surgery, Computer-Assisted/methods , Animals , Bioprosthesis , Catheterization , Heart Valve Prosthesis , Magnetic Resonance Imaging, Cine , Swine , Treatment Outcome
15.
J Cardiovasc Magn Reson ; 11: 29, 2009 Aug 12.
Article in English | MEDLINE | ID: mdl-19674464

ABSTRACT

BACKGROUND: Catheter visualization and tracking remains a challenge in interventional MR.Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. RESULTS: The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2 degrees C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. CONCLUSION: We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.


Subject(s)
Alloys , Catheterization, Peripheral/instrumentation , Copper , Magnetic Resonance Imaging, Interventional/instrumentation , Polymers , Animals , Aorta/anatomy & histology , Equipment Design , Femoral Artery/anatomy & histology , Materials Testing , Models, Animal , Phantoms, Imaging , Pliability , Subclavian Artery/anatomy & histology , Swine , Temperature , Torque
16.
J Magn Reson Imaging ; 30(2): 461-5, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19629968

ABSTRACT

PURPOSE: To develop an "active" (receiver-coil) clinical-grade guidewire with enhanced visibility for magnetic resonance imaging (MRI) and favorable mechanical characteristics for interventional MRI procedures that require conspicuous intravascular instruments distinguishable from surrounding tissues. MATERIALS AND METHODS: We designed a 0.035-inch guidewire combining two antenna designs on separate channels. A loop antenna visualizes the tip and a dipole antenna visualizes the whole shaft. We compared mechanical characteristics of this guidewire with x-ray alternatives and tested MRI performance at 1.5T in vitro and in vivo in swine. RESULTS: Images reflected tip position within 0.97 +/- 0.42 mm and afforded whole-shaft visibility under expected conditions without sacrificing device size or handling. We report tip stiffness, torquability, and pushability comparable to commercial interventional guidewires. CONCLUSION: Our clinical-grade 0.035-inch active guidewire is conspicuous under MRI and has mechanical performance comparable to x-ray interventional guidewires. This may enable a range of interventional procedures using real-time MRI.


Subject(s)
Cardiovascular Diseases/therapy , Magnetic Resonance Imaging, Interventional/instrumentation , Equipment Design , Humans
17.
Magn Reson Med ; 61(6): 1425-33, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19353673

ABSTRACT

The temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) algorithm for parallel MRI was modified for real-time low latency imaging in interventional procedures using image domain, B(1)-weighted reconstruction. GRAPPA coefficients were calculated in k-space, but applied in the image domain after appropriate transformation. Convolution-like operations in k-space were thus avoided, resulting in improved reconstruction speed. Image domain GRAPPA weights were combined into composite unmixing coefficients using adaptive B(1)-map estimates and optimal noise weighting. Images were reconstructed by pixel-by-pixel multiplication in the image domain, rather than time-consuming convolution operations in k-space. Reconstruction and weight-set calculation computations were parallelized and implemented on a general-purpose multicore architecture. The weight calculation was performed asynchronously to the real-time image reconstruction using a dedicated parallel processing thread. The weight-set coefficients were computed in an adaptive manner with updates linked to changes in the imaging scan plane. In this implementation, reconstruction speed is not dependent on acceleration rate or GRAPPA kernel size.


Subject(s)
Algorithms , Heart/anatomy & histology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Humans , Reproducibility of Results , Sensitivity and Specificity
18.
J Cardiovasc Magn Reson ; 10: 62, 2008 Dec 29.
Article in English | MEDLINE | ID: mdl-19114017

ABSTRACT

The often touted advantages of MR guidance remain largely unrealized for cardiovascular interventional procedures in patients. Many procedures have been simulated in animal models. We argue these opportunities for clinical interventional MR will be met in the near future. This paper reviews technical and clinical considerations and offers advice on how to implement a clinical-grade interventional cardiovascular MR (iCMR) laboratory. We caution that this reflects our personal view of the "state of the art."


Subject(s)
Cardiac Catheterization , Cardiovascular Diseases/pathology , Magnetic Resonance Imaging, Interventional , Angioplasty, Balloon, Coronary , Animals , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiovascular Diseases/physiopathology , Cardiovascular Diseases/therapy , Electrophysiologic Techniques, Cardiac , Embolization, Therapeutic , Equipment Design , Heart Valve Prosthesis Implantation , Hemodynamics , Humans , Magnetic Resonance Imaging, Interventional/adverse effects , Magnetic Resonance Imaging, Interventional/instrumentation , Monitoring, Physiologic , Operating Rooms/organization & administration , Predictive Value of Tests , Stents , Treatment Outcome
19.
Med Image Comput Comput Assist Interv ; 11(Pt 2): 163-70, 2008.
Article in English | MEDLINE | ID: mdl-18982602

ABSTRACT

Real-time parallel MRI reconstruction was demonstrated using a hybrid implementation of the TGRAPPA algorithm. The GRAPPA coefficients were calculated in k-space and applied in the image domain after appropriate transformation, thereby achieving improved speed and excellent image quality. Adaptive B1-weighted combining of the per coil images permitted use of pre-calculated composite image domain weights providing significant decrease in computation. The weight calculation was decoupled from the real-time image reconstruction as a parallel processing thread which was updated in an adaptive manner to speed convergence in the event of interactive change in scan plane. The computation was parallelized and implemented on a general purpose multi-core architecture. Reconstruction speeds of 65-70 frames per second were achieved with a matrix of 192 x 144 with 15 coils.


Subject(s)
Algorithms , Artificial Intelligence , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Pattern Recognition, Automated/methods , User-Computer Interface , Computer Systems , Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
20.
J Magn Reson Imaging ; 28(3): 621-5, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18777543

ABSTRACT

PURPOSE: To compare a free-breathing, nongated, and black-blood real-time delayed enhancement (RT-DE) sequence to the conventional inversion recovery gradient echo (IR-GRE) sequence for delayed enhancement MRI. MATERIALS AND METHODS: Twenty-three patients with suspected myocardial infarct (MI) were examined using both the IR-GRE and RT-DE imaging sequences. The sensitivity and specificity of RT-DE for detecting MI, using IR-GRE as the gold standard, was determined. The contrast-to-noise ratios (CNR) between the two techniques were also compared. RESULTS: RT-DE had a high sensitivity and specificity (94% and 98%, respectively) for identifying MI. The total acquisition time to image the entire left ventricle was significantly shorter using RT-DE than IR-GRE (5.6+/-0.9 versus 11.5+/-1.9 min). RT-DE had a slightly lower infarct-myocardium CNR but a higher infarct-blood CNR than IR-GRE imaging. Compared with IR-GRE, RT-DE accurately measured total infarct sizes. CONCLUSION: RT-DE can be used for delayed enhancement imaging during free-breathing and without cardiac gating.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Respiratory-Gated Imaging Techniques/methods , Aged , Computer Systems , Female , Humans , Male , Reproducibility of Results , Respiratory Mechanics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...