Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters











Publication year range
1.
ACS Omega ; 6(1): 594-605, 2021 Jan 12.
Article in English | MEDLINE | ID: mdl-33458511

ABSTRACT

Cocaine (COC) is one of the most widely consumed illegal drugs around the world. Street COC is commonly adulterated with pharmaceutical compounds that mimic or intensify the COC's sensory effect. Adulteration is performed to increase the profit of criminal organizations and each one has their own way of doing it. Therefore, determining the composition of seized COC samples (chemical profile) provides evidence for the police to track criminal organization networks and their activity patterns. Using filter paper as a substrate, we developed a multiple detection paper-based analytical device (PAD) that combines colorimetric and electrochemical measurements to discriminate COC samples according to adulterant's content. A regular graphite lead modified with a gold film made from Au leaf (graphite/Au) to improve electron transfer was used as a working electrode. Silver and Ag/AgCl were used as auxiliary and reference electrodes, respectively. The colorimetric device was patterned using a laser cutter and coupled to the electrochemical device using a double-sided tape, allowing simultaneous analysis to gather more analytical information about COC samples. Graphite/Au was characterized by scanning and transmission electron microscopies and electrochemical assays. The simultaneous colorimetric and electrochemical analyses combined to principal component analysis improved the analytical characterization of COC trial samples and provided a fast discrimination based on the assembled database.

2.
Talanta ; 223(Pt 2): 121780, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33298285

ABSTRACT

A new composite electrode (G-PSE) was developed from graphite powder and expanded polystyrene (EPS, Styrofoam) by simply dissolving the foam in chloroform, incorporating the graphite particles under mixing and volatilizing the solvent at 80 °C. The resulting rigid black composite can be softened with acetone and so it can easily be molded to any shape, e.g., into a PTFE tube with an electric contact, to build the electrode. A 75% graphite content (w/w) was found appropriate for preparing the G-PSE with a working potential similar to that of carbon paste electrodes, superior mechanical stability and a much faster response to ferrocyanide, close to reversible and similar to that of the much more expensive glassy carbon electrode. Applications of the G-PSE to dipyrone and paracetamol quantification in pharmaceutical formulations were demonstrated. The results accomplished by flow injection analysis with amperometric detection at the G-PSE were successfully validated against standards methods.

3.
ESC Heart Fail ; 7(4): 1744-1752, 2020 08.
Article in English | MEDLINE | ID: mdl-32383349

ABSTRACT

AIMS: Exhaled breath acetone (EBA) has been described as a new biomarker of heart failure (HF) diagnosis. EBA concentration increases according to severity of HF and is associated with poor prognosis, especially in acute decompensated HF. However, there are no data on chronic HF patients. The aim is to evaluate the role of EBA for predicting cardiac and overall mortality in chronic HF patients. METHODS AND RESULTS: In GENIUS-HF cohort, chronic patients were enrolled between August 2012 and December 2014. All patients had left ventricular ejection fraction ≤ 50%, and the diagnosis was established according to Framingham criteria. After consent, patients were submitted to clinical evaluation and exhaled breath collection. EBA identification and quantitative determination were done by spectrophotometry. The clinical characteristics associated with acetone were identified. All participants were followed for 18 months to assess cardiac and overall mortality. Around 700 participants were enrolled in the current analysis. Patients were 55.4 ± 12.2 years old, 67.6% male patients, and 81% New York Heart Association I/II with left ventricular ejection fraction of 32 ± 8.6%. EBA median concentration was 0.6 (0.3-1.2) ug/L. Acetone levels increased with the number of symptoms of HF and were associated with right HF signs/symptoms and liver biochemical changes. EBA at highest quartile (EBA > 1.2ug/L) was associated with a significantly worse prognosis (log rank test, P < 0.001). Cox proportional multivariable regression model revealed that EBA > 1.20ug/L was an independent predictor of cardiac (P = 0.011) and overall (P = 0.010) mortality in our population. CONCLUSIONS: This study shows that EBA levels reflect clinical HF features, especially right HF signs/symptoms. EBA is an independent predictor of cardiac and overall mortality in chronic HF patients.


Subject(s)
Acetone , Heart Failure , Adult , Aged , Exhalation , Female , Heart Failure/diagnosis , Humans , Male , Middle Aged , Stroke Volume , Ventricular Function, Left
4.
Chem Res Toxicol ; 31(5): 332-339, 2018 05 21.
Article in English | MEDLINE | ID: mdl-29707942

ABSTRACT

Air pollution is a major environmental risk for human health. Acetaldehyde is present in tobacco smoke and vehicle exhaust. In this study, we show that [13C2]-acetaldehyde induces DNA modification with the formation of isotopically labeled 1, N2-propano-2'-deoxyguanosine adducts in the brain and lungs of rats exposed to concentrations of acetaldehyde found in the atmosphere of megacities. The adduct, with the addition of two molecules of isotopically labeled acetaldehyde [13C4]-1, N2-propano-dGuo, was detected in the lung and brain tissues of exposed rats by micro-HPLC/MS/MS. Structural confirmation of the products was unequivocally performed by nano-LC/ESI+-HRMS3 analyses. DNA modifications induced by acetaldehyde have been regarded as a key factor in the mechanism of mutagenesis and may be involved in the cancer risks associated with air pollution.


Subject(s)
Acetaldehyde/toxicity , Brain/drug effects , Brain/metabolism , DNA Adducts/biosynthesis , Lung/drug effects , Lung/metabolism , Acetaldehyde/administration & dosage , Acetaldehyde/chemistry , Animals , Carbon Isotopes , DNA Adducts/chemistry , DNA Adducts/isolation & purification , Male , Molecular Structure , Rats , Rats, Wistar
5.
Langmuir ; 31(14): 4351-60, 2015 Apr 14.
Article in English | MEDLINE | ID: mdl-25812035

ABSTRACT

The structure of polytetraruthenated nickel porphyrin was unveiled for the first time by electrochemistry, Raman spectroelectrochemistry, and a hydroxyl radical trapping assay. The electrocatalytic active material, precipitated on the electrode surface after successive cycling of [NiTPyP{Ru(bipy)2Cl}4](4+) species in strong aqueous alkaline solution (pH 13), was found to be a peroxo-bridged coordination polymer. The electropolymerization process involves hydroxyl radicals (as confirmed by the characteristic set of DMPO/(•)OH adduct EPR peaks) as reaction intermediates, electrocatalytically generated in the 0.80-1.10 V range, that induce the formation of Ni-O-O-Ni coordination polymers, as evidenced by Raman spectroelectrochemistry and molecular modeling studies. The film growth is halted above 1.10 V due to the formation of oxygen gas bubbles.

6.
Free Radic Biol Med ; 75 Suppl 1: S41, 2014 Oct.
Article in English | MEDLINE | ID: mdl-26461370

ABSTRACT

Air pollution is a major risk for human health. Acetaldehyde is an environmental pollutant present in tobacco smoke, vehicle exhaust and several food products. Formation of DNA adducts has been regarded as a critical factor in the mechanisms of acetaldehyde mutagenicity and carcinogenesis. Acetaldehyde reacts with 2'-deoxyguanosine in DNA to primarily form N(2)-ethylidene-2'-deoxyguanosine (N(2)-ethylidene-dGuo). The subsequent reaction of N(2)-ethylidene-dGuo with another molecule of acetaldehyde gives rise to 1,N(2)-propano-2´-deoxyguanosine (1,N(2)-propanodGuo). In this study, on-line reverse-phase high-performance liquid chromatography (HPLC) separation with tandem mass spectrometry detection was utilized for the accurate quantification of 1,N(2)-propanodGuo and 1,N(2)-etheno-2'-deoxyguanosine (1,N(2)-edGuo) in tissues of rats exposed to 12 ppb, 33 ppb and 96 ppb acetaldehyde in atmospheric air for 50 days. A significant increase in the levels of 1,N(2)-propanodGuo was observed in lung tissues of rats exposed to 12 ppb (7.8/10(8) dGuo); 33 ppb (8.9/10(8) dGuo) and 96 ppb (11.6/10(8) dGuo) compared to controls (4.2/10(8) dGuo). For comparative purposes, the levels of 1,N(2)-etheno-2'-deoxyguanosine (1,N(2)-edGuo), which is produced from a,b-unsaturated aldehydes formed during the lipid peroxidation process were also measured. Elevated levels of 1,N(2)-edGuo were observed only in lung tissues of animals exposed to 96 ppb acetaldehyde. 1,N(2)-propanodGuo also differed quantitatively in liver but not in brain. The monitoring of 1,N(2)-propanodGuo levels in tissues provides important information on acetaldehyde genotoxicity and may contribute to the elucidation of the mechanisms associated with acetaldehyde exposure and cancer risk. Supported byFAPESP:2011/10048-5, CAPES, INCT Redoxoma:573530/2008-4,NAP Redoxoma: 2011.1.9352.1.8, CEPID Redoxoma:2013/07937-8.

7.
Talanta ; 83(1): 84-92, 2010 Nov 15.
Article in English | MEDLINE | ID: mdl-21035648

ABSTRACT

The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the µg m(-3) range) and their variations with sampling site and time. In this work, a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE), a quick separation technique that requires nothing more than some nanoliters of sample and, when combined with capacitively coupled contactless conductometric detection (C(4)D), is particularly favorable for ionic species that do not absorb in the UV-vis region, like the target analytes formaldehyde, formic acid, acetic acid and ammonium. The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry's constant such as formaldehyde and carboxylic acids, or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8.3 nL s(-1)), while the sample was aspirated through the annular gap of the concentric tubes at 2.5 mL s(-1). A second unit, in all similar to the CMDS, was operated as a capillary membrane diffusion emitter (CMDE), generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS. The fluids of the system were driven with inexpensive aquarium air pumps, and the collected samples were stored in vials cooled by a Peltier element. Complete protocols were developed for the analysis, in air, of NH(3), CH(3)COOH, HCOOH and, with a derivatization setup, CH(2)O, by associating the CMDS collection with the determination by CE-C(4)D. The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot's reaction. Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction, solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW). All techniques and methods of this work are in line with the green analytical chemistry trends.


Subject(s)
Acetic Acid/isolation & purification , Air Pollutants/isolation & purification , Air/analysis , Ammonia/isolation & purification , Formaldehyde/isolation & purification , Formates/isolation & purification , Acetic Acid/analysis , Air Pollutants/analysis , Ammonia/analysis , Electrophoresis, Capillary/methods , Formaldehyde/analysis , Formates/analysis , Gases/analysis , Membranes, Artificial , Polypropylenes/chemistry , Porosity , Sensitivity and Specificity
8.
Talanta ; 82(2): 790-5, 2010 Jul 15.
Article in English | MEDLINE | ID: mdl-20602971

ABSTRACT

A sensitive and robust analytical method for spectrophotometric determination of ethyl xanthate, CH(3)CH(2)OCS(2)(-) at trace concentrations in pulp solutions from froth flotation process is proposed. The analytical method is based on the decomposition of ethyl xanthate, EtX(-), with 2.0 mol L(-1) HCl generating ethanol and carbon disulfide, CS(2). A gas diffusion cell assures that only the volatile compounds diffuse through a PTFE membrane towards an acceptor stream of deionized water, thus avoiding the interferences of non-volatile compounds and suspended particles. The CS(2) is selectively detected by UV absorbance at 206 nm (epsilon=65,000 L mol(-1) cm(-1)). The measured absorbance is directly proportional to EtX(-) concentration present in the sample solutions. The Beer's law is obeyed in a 1x10(-6) to 2x10(-4) mol L(-1) concentration range of ethyl xanthate in the pulp with an excellent correlation coefficient (r=0.999) and a detection limit of 3.1x10(-7) mol L(-1), corresponding to 38 microg L(-1). At flow rates of 200 microL min(-1) of the donor stream and 100 microL min(-1) of the acceptor channel a sampling rate of 15 injections per hour could be achieved with RSD<2.3% (n=10, 300 microL injections of 1x10(-5) mol L(-1) EtX(-)). Two practical applications demonstrate the versatility of the FIA method: (i) evaluation the free EtX(-) concentration during a laboratory study of the EtX(-) adsorption capacity on pulverized sulfide ore (pyrite) and (ii) monitoring of EtX(-) at different stages (from starting load to washing effluents) of a flotation pilot plant processing a Cu-Zn sulfide ore.


Subject(s)
Carbon Disulfide/analysis , Gases/chemistry , Thiones/analysis , Carbon Disulfide/chemistry , Diffusion , Flow Injection Analysis/methods , Spectrophotometry, Ultraviolet/instrumentation , Spectrophotometry, Ultraviolet/methods
9.
Talanta ; 76(2): 271-5, 2008 Jul 15.
Article in English | MEDLINE | ID: mdl-18585276

ABSTRACT

Compared to other volatile carbonylic compounds present in outdoor air, formaldehyde (CH(2)O) is the most toxic, deserving more attention in terms of indoor and outdoor air quality legislation and control. The analytical determination of CH(2)O in air still presents challenges due to the low-level concentration (in the sub-ppb range) and its variation with sampling site and time. Of the many available analytical methods for carbonylic compounds, the most widespread one is the time consuming collection in cartridges impregnated with 2,4-dinitrophenylhydrazine followed by the analysis of the formed hydrazones by HPLC. The present work proposes the use of polypropylene hollow porous capillary fibers to achieve efficient CH(2)O collection. The Oxyphan fiber (designed for blood oxygenation) was chosen for this purpose because it presents good mechanical resistance, high density of very fine pores and high ratio of collection area to volume of the acceptor fluid in the tube, all favorable for the development of air sampling apparatus. The collector device consists of a Teflon pipe inside of which a bundle of polypropylene microporous capillary membranes was introduced. While the acceptor passes at a low flow rate through the capillaries, the sampled air circulates around the fibers, impelled by a low flow membrane pump (of the type used for aquariums ventilation). The coupling of this sampling technique with the selective and quantitative determination of CH(2)O, in the form of hydroxymethanesulfonate (HMS) after derivatization with HSO(3)(-), by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) enabled the development of a complete analytical protocol for the CH(2)O evaluation in air.


Subject(s)
Air Pollutants/analysis , Conductometry/methods , Electrophoresis, Capillary/methods , Formaldehyde/analysis , Equipment Design , Polypropylenes
10.
Talanta ; 72(3): 1017-22, 2007 May 15.
Article in English | MEDLINE | ID: mdl-19071718

ABSTRACT

A simple and sensitive spectrophotometric flow method for determination of low concentrations of the flotation collector O-ethyldithiocarbonate (ethyl xanthate, CH(3)CH(2)-O-CS(2)(-)) in solutions is described. The method is based on ethyl xanthate detection at 301nm in medium of NaOH 50mmolL(-1). By injection of 200muL of sample, the analytical method shows linear response for the ethyl xanthate concentration from 0.5 up to 500mumolL(-1). Successive injections of 4mumolL(-1) ethyl xanthate (n=23) show a coefficient of variation lower than 0.6%, denoting high repeatability. The detection limit is 0.3mumolL(-1). At a flow rate of 2.0mLmin(-1), a frequency of 120injections/h of ethyl xanthate can be attained. By introduction of a tangential dialysis cell in the FIA system, the manual sample filtration step with 0.22mum filter was eliminated and the residual interference of suspended material, was completely overcome even for unfiltered sludge suspension samples, an important advantage that compensates for the frequency reduction to 25injections/h elevation and detection limit elevation to 2mumolL(-1), still outreaching for many applications. Potential applications of the method embrace the at line determination of ethyl xanthate in the ore processing industry, control of the concentration at its optimal level during the flotation process, as well as monitoring of residues in the effluents.

11.
Talanta ; 69(1): 204-9, 2006 Mar 15.
Article in English | MEDLINE | ID: mdl-18970555

ABSTRACT

A chemometric method for analysis of conductometric titration data was introduced to extend its applicability to lower concentrations and more complex acid-base systems. Auxiliary pH measurements were made during the titration to assist the calculation of the distribution of protonable species on base of known or guessed equilibrium constants. Conductivity values of each ionized or ionizable species possibly present in the sample were introduced in a general equation where the only unknown parameters were the total concentrations of (conjugated) bases and of strong electrolytes not involved in acid-base equilibria. All these concentrations were adjusted by a multiparametric nonlinear regression (NLR) method, based on the Levenberg-Marquardt algorithm. This first conductometric titration method with NLR analysis (CT-NLR) was successfully applied to simulated conductometric titration data and to synthetic samples with multiple components at concentrations as low as those found in rainwater (approximately 10 micromol L(-1)). It was possible to resolve and quantify mixtures containing a strong acid, formic acid, acetic acid, ammonium ion, bicarbonate and inert electrolyte with accuracy of 5% or better.

12.
Anal Chim Acta ; 571(2): 218-27, 2006 Jul 07.
Article in English | MEDLINE | ID: mdl-17723442

ABSTRACT

The shortage of ready to use small sized liquid propulsion and switching devices for microfluidic cells (micro-cell) is a bottleneck in the dissemination of micro-flow analysis (mu-FA), now that microfluidic electrochemical cells can be designed and assembled in any laboratory by thermal transfer of laser printed masks and CD-Rs. Microprocessor-controlled electronic pipettors, commercially available with minimum capacity of 10 microL, represent a compromise solution between oversized peristaltic pumps and tiny "on a chip" micropumps and valves. The versatility of the electronic pipette coupled with the mu-cell (13-microm deep longitudinal channel) was demonstrated in three operation modes: SIA like, FIA like and direct injection analysis (DIA). Injections of 100 nL K4Fe(CN)6 (0.1 mol L(-1) KCl) define a linear analytical curve (r=0.999) in the range of 5 x 10(-7) to 1.0 x 10(-3) mol L(-1) for flow amperometry at a gold electrode potentiostated at 0.4V versus Ag/AgCl. Methods for the amperometric mu-flow determination of promethazine (FIA like), dipyrone (SIA like) and chlorpromazine (DIA) in pharmaceutical formulations were developed and applied to real samples. Excellent linearity of analytical curves and high repeatability (R.S.D.<3.0%) at the low picomole range was obtained and all results for real samples were in agreement with reference methods. The results reflect the stability and the reliability of the setups envisioned for the electronic pipette coupled with amperometric mu-cell and the validity of the mu-FA methods.

13.
J Pharm Biomed Anal ; 37(2): 281-6, 2005 Feb 23.
Article in English | MEDLINE | ID: mdl-15708668

ABSTRACT

An original, simple and sensitive flow-injection spectroelectroanalytical method for the determination of chlorpromazine in pure form or in pharmaceutical formulations is described. The method is based on the formation of a stable cationic radical by electro-oxidation in sulfuric acid medium (0.1 mol l(-1)), monitored in situ at lambda=524 nm. The determination of chlorpromazine hydrochloride in pure form or in pharmaceutical formulations was explored, considering the amperometric and the absorptiometric signal. The association of these two signals enhanced the selectivity of the analysis and proved decisive when other electroactive compounds or excipients like ascorbic acid were present in the formulation. The analytical parameters have been evaluated and the results obtained using standard additions are in agreement with the reference methods.


Subject(s)
Antipsychotic Agents/analysis , Chlorpromazine/analysis , Flow Injection Analysis/methods , Antipsychotic Agents/chemistry , Ascorbic Acid/chemistry , Chlorpromazine/chemistry , Electrochemistry , Oxidation-Reduction , Sulfuric Acids/chemistry
14.
Talanta ; 66(1): 118-24, 2005 Mar 31.
Article in English | MEDLINE | ID: mdl-18969970

ABSTRACT

It is demonstrated for the first time that the principal constituents of a shampoo as well as of a liquid soap -three surfactants and water- can be determined directly, simultaneously and quickly in undiluted samples by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy in the middle infrared region, despite the broad absorption bands of the solvent. Two of the surfactants, sodium lauryl ether sulfate (SLES) and cocoamidopropyl betaine (CAPB), are common to both formulations; alkylpolyglucoside (APG) is the third surfactant of the liquid soap and cocodiethanolamide (CDEA), the corresponding ingredient of the shampoo. Absorbance data of the undiluted samples and of the calibration standards was collected in the middle infrared region of the spectrum (800-1600 and 1900-3000cm(-1)). Two methods of multivariate quantification were compared: classical least squares (CLS), where absorbance data measured at 200 wavenumbers was processed, and inverse least squares (ILS), where data at 10 selected wavenumbers was analyzed. A spectra normalization procedure, based on a dominating water band, was examined. Twenty-seven standard mixtures were used for each application, consisting of all combinations at three concentration levels of each surfactant, respectively the lower limit, the expected value and the upper limit accepted in quality control. By favoring wavenumbers where absorption bands of the minor components (APG in the liquid soap and CDEA in the shampoo) are more intense, good results were obtained for 18 simulated samples of shampoo and 18 samples of liquid soap, no matter if calculations were made by CLS or ILS. The relative errors for water (major component, 84-88%) and SLES (7-10%) were always below 2%; for CAPB (2-4%), APG (<2%) and CDEA (<2%), they occasionally reached 5% of the component, an uncertainty of less than 0.07% in terms of the sample weight.

15.
Talanta ; 67(3): 651-7, 2005 Sep 15.
Article in English | MEDLINE | ID: mdl-18970220

ABSTRACT

A simple and reliable FIA-potentiometric system for rapid assays of chloride in certain food samples is described and evaluated. The system is constituted by an aquarium air pump to propel the carrier solution, a manually operated injector, a homemade dialysis flow cell, a solid-state chloride detector (Ag/AgCl), a reference electrode and a multimeter connected to a microcomputer for data acquisition. The dialysis unit enables direct analysis of liquid food samples without any other previous treatment. The principal novelties are the precision (R.S.D. of 1.2% for whole milk) and rapidity (90 determinations/h) of FIA measurements near and below the lower end of the linear (Nernstian) response region of the chloride ion-selective electrode (ISE), with an estimated detection limit (3s) of 0.4mgL(-1) Cl(-) in the sample injected in donor stream. Data of peak potential versus sample chloride concentration (donor stream) was accurately fitted with a quadratic polynomial over the range between 4 and 1000mgL(-1) (r(2)=0.9999) and used as a calibration curve. The method was applied to the determination of chloride in milk and in coconut water samples. The validation of the results was done by comparison with a NIST reference material (milk) or by capillary electrophoresis (coconut water). For all analysis, no significant difference at a 95% confidence level was observed.

16.
Talanta ; 67(4): 791-7, 2005 Oct 15.
Article in English | MEDLINE | ID: mdl-18970241

ABSTRACT

The new electrolytic dissolution in batch of aluminum alloys samples as grains or turns and the determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb and Ti by ICP OES was investigated. In on-line electrodissolution procedures described in the literature, samples were restricted to be in the form of solid blocks or plates with one polished flat face. Here, the sample was loaded in the barrel of a modified disposable syringe (the anodic semi-cell) and pressed with a modified plunger fitted with a platinum disk to establish electrical contact with the analyte. This arrangement was introduced in a beaker containing the electrolyte (1 mol L(-1) HNO(3)) and a platinum wire as the cathode. The resulting solution from electrodissolution (0.6A) was used for the ICP OES determinations. The influence of the aluminum concentration increase on the determination of the elements was evaluated. Electrodissolution of certified reference materials and commercial samples revealed relative errors lower than 10% for the elements Fe, Cu, Mg, Ni, Cr, Zn and Ti (when their content is above 0.1%). Higher inaccuracies (>10%) were observed for Mn and for Fe in B.C.S. 268/1 reference material certified. The proposed method presented a relative standard deviations (R.S.D.) lower or circa 10% to all of the elements (except Pb). In comparison with traditional acid dissolution, the proposed electrodissolution method is relatively fast (about 30 min), it is clean (there is no projection of solution) and simple (heating and fumes exhaust system were not necessary).

17.
Talanta ; 68(2): 429-36, 2005 Dec 15.
Article in English | MEDLINE | ID: mdl-18970340

ABSTRACT

Microfluidic flow cells combined with an interdigitated array (IDA) electrode and/or individually driven interdigitated electrodes were fabricated and characterized for application as detectors for flow injection analysis. The gold electrodes were produced by a process involving heat transfer of a toner mask onto the gold surface of a CD-R and etching of the toner-free gold region by short exposure to iodine-iodide solution. The arrays of electrodes with individual area of 0.01cm(2) (0.10cm of lengthx0.10cm of width and separated by gaps of 0.05 or 0.03cm) were assembled in microfluidic flow cells with 13 or 19mum channel depth. The electrochemical characterization of the cells was made by voltammetry under stationary conditions and the influence of experimental parameters related to geometry of the channels and electrodes were studied by using K(4)Fe(CN)(6) as model system. The obtained results for peaks currents (I(p)) are in excellent agreement with the expected ones for a reversible redox system under stationary thin-layer conditions. Two different configurations of the working electrodes, E(i), auxiliary electrode, A, and reference electrode, R, on the chip were examined: E(i)/R/A and R/E(i)/A, with the first presenting certain uncompensated resistance. This is because the potentiostat actively compensates the iR drop occurring in the electrolyte thin layer between A and R, but not from R to each E(i). This is confirmed by the smaller difference between the cathodic and anodic peak potentials for the second configuration. Evaluation of the microfluidic flow cells combined with (individually driven) interdigitated array electrodes as biamperometric or amperometric detectors for FIA reveals stable and reproducible operation, with peak heights presenting relative standard deviations of less than 2.2%. For electrochemically reversible species, FIA peaks with enhanced current signal were obtained due to redox cycling under flow operation. The versatility of microfluidic flow cells, produced by simple and low-cost technique, associated with the rich information content of electrochemical techniques with arrays of electrodes, opens many future research and application opportunities.

18.
Talanta ; 60(4): 695-705, 2003 Jul 04.
Article in English | MEDLINE | ID: mdl-18969094

ABSTRACT

A simple, robust and fast-responding flow adaptor for mercury drop electrodes (MDEs) is described. An L-shaped PTFE tube with an internal diameter of 0.5 mm is fixed with a silicone ring on the glass capillary of a MDE, in such a way as to direct the outcoming flow onto the mercury drop, from a distance of about 0.5 mm. Any commercial or laboratory-made batch cell, provided with an MDE, serves for the purpose. The level of supporting electrolyte in the cell is maintained constant through a siphon or a lateral draining orifice. The adaptor is compatible with all the different brands and operating modes of the MDEs (free dropping, controlled drop time, renewable static drop, hanging drop or sessile drop). Flow injection experiments were conducted with the following amperometric detection modes: sampled-DC, reverse pulse amperometry (RPA), and anodic stripping voltammetry (ASV). The FIA-RPA peaks presented a R.S.D.<0.8% for 1.0x10(-5) mol l(-1) lead(II) (N=30, V(sample)=100 mul). The response time (0-63% of the signal maximum) to a concentration step is 1.2 s for 500 mul injections of 0.1 mmol l(-1) ascorbic acid in acetate buffer at a flow rate of 1 ml min(-1), which corresponds to a response volume of 20 mul. As an example of practical application, copper(II) was determined in fertilizers by RPA using the standard addition method, at an analytical frequency of 90 injections per h.

SELECTION OF CITATIONS
SEARCH DETAIL