2.
Rev Med Chil ; 146(2): 190-195, 2018 Feb.
Article in Spanish | MEDLINE | ID: mdl-29999155

ABSTRACT

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. AIM: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. MATERIAL AND METHODS: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). RESULTS: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was -0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and -0.9 mmHg (95% CI -1.7 to -0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. CONCLUSIONS: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Subject(s)
Blood Pressure Determination/instrumentation , Blood Pressure Monitors , Hypertension/diagnosis , Blood Pressure Determination/methods , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Reproducibility of Results
3.
Rev. méd. Chile ; 146(2): 190-195, feb. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-961377

ABSTRACT

Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.


Subject(s)
Humans , Male , Female , Middle Aged , Blood Pressure Determination/instrumentation , Blood Pressure Monitors , Hypertension/diagnosis , Blood Pressure Determination/methods , Cross-Sectional Studies , Reproducibility of Results
4.
Blood Press Monit ; 22(6): 375-378, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28945665

ABSTRACT

OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97-190), diastolic BP was 90.9±12.9 mmHg (range: 68-120), and arm circumference was 30.8±4 cm (range: 25-38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.


Subject(s)
Blood Pressure Determination/instrumentation , Blood Pressure , Sphygmomanometers/standards , Adult , Aged , Ambulatory Care Facilities , Arm , Female , Humans , Male , Middle Aged , Self Care/instrumentation