Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Ophthalmol ; 16: 2595-2608, 2022.
Article in English | MEDLINE | ID: mdl-35992568

ABSTRACT

Purpose: To compare the reproducibility of two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness and three-dimensional (3D) neuroretinal rim measurements using spectral domain optical coherence tomography (SDOCT) in normal and glaucoma subjects. Methods: One eye per subject for 27 normal and 40 glaucoma subjects underwent repeat SDOCT RNFL thickness scans and optic nerve volume scans on the same day. From the volume scan, custom software calculated five neuroretinal rim parameters: 3D minimum distance band (MDB) thickness, 3D MDB area, 3D rim volume, 2D rim area, and 2D rim thickness. Within-subject variance (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) were analyzed. Results: MDB thickness and RNFL thickness have similar reproducibility among normal and glaucoma subjects (eg, global MDB thickness CVs of 2.4% and 3.6%, and global RNFL thickness CVs of 1.3% and 2.2%; P > 0.05 for both comparisons). Reproducibility of MDB thickness was lower in glaucoma patients for the superior and inferior quadrants compared to normal subjects (CVs of 9.6% versus 3.4% and 6.9% versus 2.7%; P < 0.05, respectively). There were no statistically significant differences between both groups for RNFL thickness in the four quadrants. For both patient groups and for all regions, MDB thickness had the lowest CVs among all five neuroretinal rim parameters (eg, global MDB thickness CVs of 2.4% and 3.6% versus 3.0% and 18.9% for the other four neuroretinal rim parameters). Conclusion: Global MDB and global RNFL thickness are similarly reproducible among normal and glaucoma subjects, though MDB thickness for the superior and inferior quadrants is less reproducible among glaucoma subjects.

2.
Am J Ophthalmol Case Rep ; 27: 101638, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35813588

ABSTRACT

Purpose: To report two pediatric cases of reticular corneal epithelial edema associated with the use of netarsudil ophthalmic solution 0.02%. Observations: In Case 1, a six-year-old male with glaucoma following cataract surgery was treated with netarsudil for thirteen months and developed diffuse reticular corneal epithelial edema on post-operative day one after undergoing transscleral diode cyclophotocoagulation for persistently elevated intraocular pressures. In Case 2, a three-month-old male with bilateral ocular hypertension developed unilateral inferior reticular corneal epithelial edema five weeks after initiation of netarsudil, which had been discontinued in the fellow eye two weeks prior. In both cases, the reticular epithelial edema resolved following cessation of netarsudil. Conclusions and Importance: Netarsudil-associated reticular corneal epithelial edema can occur in infants and young children.

3.
Curr Opin Ophthalmol ; 33(2): 103-111, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-34864763

ABSTRACT

PURPOSE OF REVIEW: To summarize the literature on three-dimensional (3D) technological advances in ophthalmology, the quantitative methods associated with this, and their improved ability to help detect glaucoma disease progression. RECENT FINDINGS: Improvements in measuring glaucomatous structural changes are the result of dual innovations in optical coherence tomography (OCT) imaging technology and in associated quantitative software. SUMMARY: Compared with two-dimensional (2D) OCT parameters, newer 3D parameters provide more data and fewer artifacts.


Subject(s)
Glaucoma , Ophthalmology , Glaucoma/diagnostic imaging , Humans , Imaging, Three-Dimensional , Technology , Tomography, Optical Coherence
4.
Digit J Ophthalmol ; 28(4): 100-109, 2022.
Article in English | MEDLINE | ID: mdl-36660188

ABSTRACT

Purpose: To determine whether intereye asymmetry of a three-dimensional neuroretinal rim parameter, the minimum distance band, is useful in differentiating normal eyes from those with open-angle glaucoma. Materials and Methods: This is a cross-sectional study of 28 normal subjects and 33 glaucoma subjects. Subjects underwent spectral domain optical coherence tomography imaging of both eyes. From high-density raster scans of the optic nerve head, a custom-designed segmentation algorithm calculated mean minimum distance band neuroretinal rim thickness globally, for four quadrants, and for four sectors. Intereye minimum distance band thickness asymmetry was calculated as the absolute difference in minimum distance band thickness values between the right and left eyes. Results: Increasing global minimum distance band thickness asymmetry was not associated with increasing age or increasing refractive error asymmetry. Glaucoma patients had thinner mean neuroretinal rim thickness values compared to normal patients (209.0 µm vs 306.0 µm [P < 0.001]). Glaucoma subjects had greater intereye thickness asymmetry compared to normal subjects for the global region (51.9 µm vs 17.6 µm [P < 0.001]) as well as for all quadrants and all sectors. For detecting glaucoma, a thickness asymmetry value >28.3 µm in the inferior quadrant yielded the greatest sum of sensitivity (87.9%) and specificity (75.0%). Globally, thickness asymmetry >30.7 µm yielded the greatest sum of sensitivity (66.7%) and specificity (89.3%). Conclusions: This study indicates that intereye neuroretinal rim minimum distance band asymmetry measurements, using high-density spectral domain optical coherence tomography volume scans, may be an objective and quantitative tool for assessing patients suspected of open-angle glaucoma.


Subject(s)
Glaucoma, Open-Angle , Glaucoma , Optic Disk , Humans , Optic Disk/diagnostic imaging , Glaucoma, Open-Angle/diagnosis , Tomography, Optical Coherence/methods , Cross-Sectional Studies , Intraocular Pressure , Retinal Ganglion Cells , Glaucoma/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...