Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Technol Ther ; 17(5): 307-10, 2015 May.
Article in English | MEDLINE | ID: mdl-25622214

ABSTRACT

BACKGROUND: To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). SUBJECTS AND METHODS: For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. RESULTS: Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. CONCLUSIONS: Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.


Subject(s)
Blood Glucose/analysis , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , Fasting/blood , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems/statistics & numerical data , Insulin/administration & dosage , Adolescent , Adult , Data Collection/methods , Dose-Response Relationship, Drug , Feasibility Studies , Female , Humans , Internet , Male , Middle Aged , Surveys and Questionnaires , Time Factors , Young Adult