Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Phys Med Biol ; 58(11): 3755-73, 2013 Jun 07.
Article in English | MEDLINE | ID: mdl-23665924

ABSTRACT

Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in the beam width could be measured with a precision of 0.9 mm. Furthermore, shifts of the lateral beam position could be monitored with a sub-millimetre precision. The presented investigations demonstrate experimentally that the non-invasive measurement and analysis of secondary ion distributions around head-sized homogeneous objects provide information on the actual beam delivery. Beam range, width and position could be monitored with a precision attractive for therapeutic situations.


Subject(s)
Heavy Ion Radiotherapy/instrumentation , Phantoms, Imaging , Humans , Neoplasms/radiotherapy , Polymethyl Methacrylate , Radiotherapy Dosage
2.
Med Phys ; 39(6Part3): 3614-3615, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517381

ABSTRACT

PURPOSE: Due to the high conformity of carbon ion therapy, unpredictable changes in the patient's geometry or deviations from the planned beam properties can result in changes of the dose distribution. PET has been used successfully to monitor the actual dose distribution in the patient. However, it suffers from biological washout processes and low detection efficiency. The purpose of this contribution is to investigate the potential of beam monitoring by detection of prompt secondary ions emerging from a homogeneous phantom, simulating a patient's head. METHODS: Measurements were performed at the Heidelberg Ion-Beam Therapy Center (Germany) using a carbon ion pencil beam irradiated on a cylindrical PMMA phantom (16cm diameter). For registration of the secondary ions, the Timepix detector was used. This pixelated silicon detector allows position-resolved measurements of individual ions (256×256 pixels, 55µm pitch). To track the secondary ions we used several parallel detectors (3D voxel detector). RESULTS: For monitoring of the beam in the phantom, we analyzed the directional distribution of the registered ions. This distribution shows a clear dependence on the initial beam energy, width and position. Detectable were range differences of 1.7mm, as well as vertical and horizontal shifts of the beam position by 1mm. To estimate the clinical potential of this method, we measured the yield of secondary ions emerging from the phantom for a beam energy of 226MeV/u. The differential distribution of secondary ions as a function of the angle from the beam axis for angles between 0 and 90° will be presented. In this setup the total yield in the forward hemisphere was found to be in the order of 10-1 secondary ions per primary carbon ion. CONCLUSIONS: The presented measurements show that tracking of secondary ions provides a promising method for non-invasive monitoring of ion beam parameters for clinical relevant carbon ion fluences. Research with the pixel detectors was carried out in frame of the Medipix Collaboration.

3.
Med Phys ; 39(6Part20): 3861, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517543

ABSTRACT

PURPOSE: Radiation therapy with ion beams provides highly conformal dose distributions. Therefore, monitoring the dose delivery within the patient in a non- invasive way is desired. The clinically available method based on tissue activation measurements with a PET-camera shows limitations due to the low induced activities and biological washout of the activated nuclei. The prompt production of secondary ions is supposed to be less influenced by biological processes. This contribution investigates the feasibility of beam range monitoring in a patient-like geometry containing realistic tissue inhomogeneities. METHODS: The experiments were performed at the Heidelberg Ion-Beam Therapy Center in Germany using carbon ion beams of 213 and 250MeV/u. Static pencil beams (FWHM of 6mm) were applied to the skull base and brain regions of a head phantom containing real bones. The emerging secondary ions were registered by the silicon detector Timepix. It was developed by the Medipix Collaboration and provides 256×256 pixels with 55um pitch. To determine the direction of the particles, a multi-layered detector (3D voxel detector, J.Jakubek etal. JINST6 C12010) was employed. The contribution of K. Gwosch etal. addresses the performance of this method in a homogeneous phantom. RESULTS: In the 3D distributions of the measured secondary ions clear differences between the application of lower and higher energies were observed. This Result was achieved in both brain (homogeneous) and skull base regions (containing inhomogeneities). Differences between the energies could be observed with the detector positioned on the occipital side as well as on the facial side of the head. CONCLUSIONS: We performed the first experiments towards beam range monitoring in a patient-like geometry exploiting tracking of prompt secondary ions with a small detector prototype. Despite the inherent tissue inhomogeneities, we found sensitivity on the beam range in both brain and skull base. Research carried out in frame of the Medipix Collaboration. Research carried out in frame of the Medipix Collaboration.

SELECTION OF CITATIONS
SEARCH DETAIL