Phys Med Biol ; 51(14): 3581-92, 2006 Jul 21.
Article in English | MEDLINE | ID: mdl-16825750

ABSTRACT

Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and long-term drifts in outputs were quantified by fitting empirical mathematical models to the QC measurements. Normally, long-term drifts were well (< or =1%) modelled by either a straight line or a single-exponential function. A drift of 2% occurred in 18 +/- 12 months. The shortest drift times of only 2-3 months were observed for some new accelerators just after the commissioning but they stabilized during the first 2-3 years. The short-term reproducibility and the long-term stability of local constancy checks, carried out with a sealed plane parallel ion chamber, were also estimated by fitting empirical models to the QC measurements. The reproducibility was 0.2-0.5% depending on the positioning practice of a device. Long-term instabilities of about 0.3%/month were observed for some checking devices. The reproducibility of local absorbed dose measurements was estimated to be about 0.5%. The proposed empirical model fitting of QC data facilitates the recognition of erroneous QC measurements and abnormal output behaviour, caused by malfunctions, offering a tool to improve dose control.


Subject(s)
Particle Accelerators , Radiometry/instrumentation , Calibration , Humans , Models, Statistical , Phantoms, Imaging , Photons , Quality Control , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results , Risk , Time Factors
2.
Radiother Oncol ; 74(3): 251-8, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15763305

ABSTRACT

BACKGROUND AND PURPOSE: To investigate the salivary gland function following intensity modulated radiotherapy (IMRT) for head and neck cancer. PATIENTS AND METHODS: Seventeen patients with oropharyngeal (n=11) or nasopharyngeal (n=6) carcinoma located adjacent to the major salivary glands were treated with IMRT with an emphasis to spare the salivary glands from high-dose irradiation and to reduce the risk of postirradiation xerostomy. Three patients had stage 2, 4 stage III, and 10 stage IVA cancer. The total basal and stimulated saliva flow rates were measured before the treatment, and 6 and 12 months after radiotherapy. RESULTS: The median basal saliva flow rate measured before radiation treatment was 0.13 mL/min, and at 6 and 12 months after the completion of IMRT 0.04 mL/min and 0.07 mL/min, respectively. The corresponding median stimulated saliva flow rates were 0.49 mL/min, 0.33 mL/min, and 0.45 mL, respectively. The D50 for an impaired stimulated parotid gland saliva flow rate was 25.5 Gy. Only two (12%) patients developed grade 3 and none grade 4 xerostomia during a median follow-up of 24 months (range, 12-40 months). No patients had locoregional cancer recurrence following IMRT. CONCLUSIONS: The results suggest that much of the salivary gland function can be maintained with IMRT without jeopardizing the local control rate in the treatment of locally advanced oropharynx or nasopharynx carcinoma.


Subject(s)
Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Oropharyngeal Neoplasms/radiotherapy , Radiation Injuries/prevention & control , Salivary Glands/physiology , Salivary Glands/radiation effects , Adult , Aged , Dose-Response Relationship, Radiation , Female , Humans , Male , Middle Aged , Salivation
SELECTION OF CITATIONS
SEARCH DETAIL
...