Nat Nanotechnol ; 19(4): 514-523, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38212522

ABSTRACT

One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.


Subject(s)
Graphite , Nanopores , Rats , Animals , Microelectrodes , Prostheses and Implants , Electric Stimulation
2.
Nat Nanotechnol ; 17(3): 301-309, 2022 03.
Article in English | MEDLINE | ID: mdl-34937934

ABSTRACT

Mapping the entire frequency bandwidth of brain electrophysiological signals is of paramount importance for understanding physiological and pathological states. The ability to record simultaneously DC-shifts, infraslow oscillations (<0.1 Hz), typical local field potentials (0.1-80 Hz) and higher frequencies (80-600 Hz) using the same recording site would particularly benefit preclinical epilepsy research and could provide clinical biomarkers for improved seizure onset zone delineation. However, commonly used metal microelectrode technology suffers from instabilities that hamper the high fidelity of DC-coupled recordings, which are needed to access signals of very low frequency. In this study we used flexible graphene depth neural probes (gDNPs), consisting of a linear array of graphene microtransistors, to concurrently record DC-shifts and high-frequency neuronal activity in awake rodents. We show here that gDNPs can reliably record and map with high spatial resolution seizures, pre-ictal DC-shifts and seizure-associated spreading depolarizations together with higher frequencies through the cortical laminae to the hippocampus in a mouse model of chemically induced seizures. Moreover, we demonstrate the functionality of chronically implanted devices over 10 weeks by recording with high fidelity spontaneous spike-wave discharges and associated infraslow oscillations in a rat model of absence epilepsy. Altogether, our work highlights the suitability of this technology for in vivo electrophysiology research, and in particular epilepsy research, by allowing stable and chronic DC-coupled recordings.


Subject(s)
Epilepsy , Graphite , Animals , Electroencephalography , Mice , Microelectrodes , Rats , Seizures
3.
Front Neurosci ; 15: 615256, 2021.
Article in English | MEDLINE | ID: mdl-33746697

ABSTRACT

Evaluating biocompatibility is a core essential step to introducing a new material as a candidate for brain-machine interfaces. Foreign body reactions often result in glial scars that can impede the performance of the interface. Having a high conductivity and large electrochemical window, graphene is a candidate material for electrical stimulation with retinal prosthesis. In this study, non-functional devices consisting of chemical vapor deposition (CVD) graphene embedded onto polyimide/SU-8 substrates were fabricated for a biocompatibility study. The devices were implanted beneath the retina of blind P23H rats. Implants were monitored by optical coherence tomography (OCT) and eye fundus which indicated a high stability in vivo up to 3 months before histology studies were done. Microglial reconstruction through confocal imaging illustrates that the presence of graphene on polyimide reduced the number of microglial cells in the retina compared to polyimide alone, thereby indicating a high biocompatibility. This study highlights an interesting approach to assess material biocompatibility in a tissue model of central nervous system, the retina, which is easily accessed optically and surgically.

4.
Bioelectrochemistry ; 129: 79-89, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31125924

ABSTRACT

When implantable recording devices for brain or neural electrical activity are designed, the number of available materials for electrodes is quite limited. The material must be biocompatible with respect to ISO10993, its electrochemical properties must remain stable and the response of cells or tissues can be mitigated, especially on the glial scar. This involves electrode characterization pre- implantation and impedance spectroscopy during chronic implantation, in order to evaluate both electrode properties and performance. This study was aimed at a comparison of the long-term behavior of a nanostructured boron-doped diamond (BDD) with a nanostructured Platinum Iridium (PtIr) electrode. Firstly, a batch of cortical grids with bare and modified contacts (2 mm in diameter) was engineered for implantation. Secondly a miniature swine model was developed. This study highlighted the predominant role of electrode surface roughness on the quality of recordings. Rough PtIr contacts and BDD coated ones showed comparable behavior after three-month implantation with a slight increase of the modulus of the impedance and a tissue capsule. Nevertheless, immunohistochemistry analysis did not exhibit either a toxic or irritation reaction. With regard to biocompatibility, promising long term results are shown for both materials.


Subject(s)
Biocompatible Materials/chemistry , Boron/chemistry , Diamond/chemistry , Electrodes, Implanted , Nanostructures/chemistry , Animals , Biocompatible Materials/adverse effects , Boron/adverse effects , Brain/ultrastructure , Diamond/adverse effects , Dielectric Spectroscopy , Electrochemical Techniques , Electrodes, Implanted/adverse effects , Glial Fibrillary Acidic Protein/analysis , Nanostructures/adverse effects , Nanostructures/ultrastructure , Swine , Swine, Miniature
5.
Nat Mater ; 18(3): 280-288, 2019 03.
Article in English | MEDLINE | ID: mdl-30598536

ABSTRACT

Recording infraslow brain signals (<0.1 Hz) with microelectrodes is severely hampered by current microelectrode materials, primarily due to limitations resulting from voltage drift and high electrode impedance. Hence, most recording systems include high-pass filters that solve saturation issues but come hand in hand with loss of physiological and pathological information. In this work, we use flexible epicortical and intracortical arrays of graphene solution-gated field-effect transistors (gSGFETs) to map cortical spreading depression in rats and demonstrate that gSGFETs are able to record, with high fidelity, infraslow signals together with signals in the typical local field potential bandwidth. The wide recording bandwidth results from the direct field-effect coupling of the active transistor, in contrast to standard passive electrodes, as well as from the electrochemical inertness of graphene. Taking advantage of such functionality, we envision broad applications of gSGFET technology for monitoring infraslow brain activity both in research and in the clinic.


Subject(s)
Brain Mapping/instrumentation , Frontal Lobe/physiology , Graphite , Microtechnology/instrumentation , Transistors, Electronic , Animals , Graphite/chemistry , Microelectrodes , Models, Molecular , Molecular Conformation , Rats
6.
Adv Mater ; 29(42)2017 Nov.
Article in English | MEDLINE | ID: mdl-28901588

ABSTRACT

Neural interfaces are becoming a powerful toolkit for clinical interventions requiring stimulation and/or recording of the electrical activity of the nervous system. Active implantable devices offer a promising approach for the treatment of various diseases affecting the central or peripheral nervous systems by electrically stimulating different neuronal structures. All currently used neural interface devices are designed to perform a single function: either record activity or electrically stimulate tissue. Because of their electrical and electrochemical performance and their suitability for integration into flexible devices, graphene-based materials constitute a versatile platform that could help address many of the current challenges in neural interface design. Here, how graphene and other 2D materials possess an array of properties that can enable enhanced functional capabilities for neural interfaces is illustrated. It is emphasized that the technological challenges are similar for all alternative types of materials used in the engineering of neural interface devices, each offering a unique set of advantages and limitations. Graphene and 2D materials can indeed play a commanding role in the efforts toward wider clinical adoption of bioelectronics and electroceuticals.

7.
Mater Sci Eng C Mater Biol Appl ; 69: 77-84, 2016 Dec 01.
Article in English | MEDLINE | ID: mdl-27612691

ABSTRACT

Nanocrystalline Boron doped Diamond proved to be a very attractive material for neural interfacing, especially with the retina, where reduce glia growth is observed with respect to other materials, thus facilitating neuro-stimulation over long terms. In the present study, we integrated diamond microelectrodes on a polyimide substrate and investigated their performances for the development of neural prosthesis. A full description of the microfabrication of the implants is provided and their functionalities are assessed using cyclic voltammetry and electrochemical impedance spectroscopy. A porous structure of the electrode surface was thus revealed and showed promising properties for neural recording or stimulation. Using the flexible implant, we showed that is possible to follow in vivo the evolution of the electric contact between the diamond electrodes and the retina over 4months by using electrochemical impedance spectroscopy. The position of the implant was also monitored by optical coherence tomography to corroborate the information given by the impedance measurements. The results suggest that diamond microelectrodes are very good candidates for retinal prosthesis.


Subject(s)
Biocompatible Materials/chemistry , Boron/chemistry , Diamond/chemistry , Animals , Dielectric Spectroscopy , Disease Models, Animal , Electrochemical Techniques , Electrodes, Implanted , Microelectrodes , Microscopy, Electron, Scanning , Porosity , Rats , Retinitis Pigmentosa/metabolism , Retinitis Pigmentosa/pathology , Tomography, Optical Coherence , Visual Prosthesis
8.
J Neural Eng ; 12(6): 066016, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26468733

ABSTRACT

OBJECTIVE: We quantitatively investigate the biocompatibility of chemical vapour deposited (CVD) nanocrystalline diamond (NCD) after the inclusion of boron, with and without nanostructuring. The nanostructuring method involves a novel approach of growing NCD over carbon nanotubes (CNTs) that act as a 3D scaffold. This nanostructuring of BNCD leads to a material with increased capacitance, and this along with wide electrochemical window makes BNCD an ideal material for neural interface applications, and thus it is essential that their biocompatibility is investigated. APPROACH: Biocompatibility was assessed by observing the interaction of human neural stem cells (hNSCs) with a variety of NCD substrates including un-doped ones, and NCD doped with boron, which are both planar, and nanostructured. hNSCs were chosen due to their sensitivity, and various methods including cell population and confluency were used to quantify biocompatibility. MAIN RESULTS: Boron inclusion into NCD film was shown to have no observable effect on hNSC attachment, proliferation and viability. Furthermore, the biocompatibility of nanostructured boron-doped NCD is increased upon nanostructuring, potentially due to the increased surface area. SIGNIFICANCE: Diamond is an attractive material for supporting the attachment and development of cells as it can show exceptional biocompatibility. When boron is used as a dopant within diamond it becomes a p-type semiconductor, and at high concentrations the diamond becomes quasi-metallic, offering the prospect of a direct electrical device-cell interfacing system.


Subject(s)
Biocompatible Materials , Boron , Cell Proliferation/physiology , Diamond , Nanostructures , Neural Stem Cells/physiology , Biocompatible Materials/chemistry , Boron/chemistry , Cell Culture Techniques/methods , Diamond/chemistry , Embryonic Stem Cells/physiology , Humans , Nanostructures/chemistry
9.
Biomaterials ; 53: 173-83, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25890717

ABSTRACT

The electrode material is a key element in the design of long-term neural implants and neuroprostheses. To date, the ideal electrode material offering high longevity, biocompatibility, low-noise recording and high stimulation capabilities remains to be found. We show that 3D-nanostructured boron doped diamond (BDD), an innovative material consisting in a chemically stable material with a high aspect ratio structure obtained by encapsulation of a carbon nanotube template within two BDD nanolayers, allows neural cell attachment, survival and neurite extension. Further, we developed arrays of 20-µm-diameter 3D-nanostructured BDD microelectrodes for neural interfacing. These microelectrodes exhibited low impedances and low intrinsic recording noise levels. In particular, they allowed the detection of low amplitude (10-20 µV) local-field potentials, single units and multiunit bursts neural activity in both acute whole embryonic hindbrain-spinal cord preparations and long-term hippocampal cell cultures. Also, cyclic voltammetry measurements showed a wide potential window of about 3 V and a charge storage capacity of 10 mC.cm(-2), showing high potentiality of this material for neural stimulation. These results demonstrate the attractiveness of 3D-nanostructured BDD as a novel material for neural interfacing, with potential applications for the design of biocompatible neural implants for the exploration and rehabilitation of the nervous system.


Subject(s)
Boron , Diamond , Microelectrodes , Neural Prostheses , Animals , Biocompatible Materials , Hippocampus/cytology , Mice , Spinal Cord/cytology
10.
Mater Sci Eng C Mater Biol Appl ; 46: 25-31, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25491956

ABSTRACT

Neural interfacing still requires highly stable and biocompatible materials, in particular for in vivo applications. Indeed, most of the currently used materials are degraded and/or encapsulated by the proximal tissue leading to a loss of efficiency. Here, we considered boron doped diamond microelectrodes to address this issue and we evaluated the performances of a diamond microelectrode array. We described the microfabrication process of the device and discuss its functionalities. We characterized its electrochemical performances by cyclic voltammetry and impedance spectroscopy in saline buffer and observed the typical diamond electrode electrochemical properties, wide potential window and low background current, allowing efficient electrochemical detection. The charge storage capacitance and the modulus of the electrochemical impedance were found to remain in the same range as platinum electrodes used for standard commercial devices. Finally we observed a reduced Magnetic Resonance Imaging artifact when the device was implanted on a rat cortex, suggesting that boron doped-diamond is a very promising electrode material allowing functional imaging.


Subject(s)
Biocompatible Materials/chemistry , Cerebral Cortex , Diamond/chemistry , Electrodes, Implanted , Magnetic Resonance Imaging/instrumentation , Neural Prostheses , Animals , Biocompatible Materials/adverse effects , Cerebral Cortex/pathology , Cerebral Cortex/surgery , Diamond/adverse effects , Male , Materials Testing , Microelectrodes , Prosthesis Implantation , Rats , Rats, Wistar
11.
Small ; 8(9): 1345-9, 2012 May 07.
Article in English | MEDLINE | ID: mdl-22383399

ABSTRACT

By applying an external electric field across a micropore via an electrolyte, metal ions in the electrolyte can be reduced locally onto the inner wall of the micropore, which was fabricated in a silica-covered silicon membrane. This maskless metal deposition on the silica surface is a result of the pore membrane polarization in the electric field.