Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Magn Reson ; 237: 182-190, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24252245

ABSTRACT

In ultra-low-field (ULF) NMR/MRI, a common scheme is to magnetize the sample by a polarizing field of up to hundreds of mT, after which the NMR signal, precessing in a field on the order of several µT, is detected with superconducting quantum interference devices (SQUIDs). In our ULF-NMR system, we polarize with up to 50mT and deploy a single-stage DC-SQUID current sensor with an integrated input coil which is connected to a wire-wound Nb gradiometer. We developed this system (white noise 0.50fT/√Hz) for assessing the feasibility of imaging neuronal currents by detecting their effect on the ULF-NMR signal. Magnetoencephalography investigations of evoked brain activity showed neuronal dipole moments below 50nAm. With our instrumentation, we have studied two different approaches for neuronal current imaging. In the so-called DC effect, long-lived neuronal activity shifts the Larmor frequency of the surrounding protons. An alternative strategy is to exploit fast neuronal activity as a tipping pulse. This so-called AC effect requires the proton Larmor frequency to match the frequency of the neuronal activity, which ranges from near-DC to ∼kHz. We emulated neuronal activity by means of a single dipolar source in a physical phantom, consisting of a hollow sphere filled with an aqueous solution of CuSO4 and NaCl. In these phantom studies, with physiologically relevant dipole depths, we determined resolution limits for our set-up for the AC and the DC effect of ∼10µAm and ∼50nAm, respectively. Hence, the DC effect appears to be detectable in vivo by current ULF-NMR technology.


Subject(s)
Magnetic Resonance Imaging/methods , Neurons/physiology , Phantoms, Imaging , Adult , Algorithms , Brain/physiology , Electric Stimulation , Electrodes , Electromagnetic Fields , Humans , Magnetoencephalography , Male , Models, Statistical , Signal-To-Noise Ratio
2.
Magn Reson Imaging ; 29(10): 1365-73, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21907519

ABSTRACT

A number of different methods have been developed in order to detect the spreading of neuronal currents by means of noninvasive imaging techniques. However, all of these are subjected to limitations in the temporal or spatial resolution. A new approach of neuronal current detection is based on the use of low-field nuclear magnetic resonance (LF-NMR) that records brain activity directly. In the following, we describe a phantom study in order to assess the feasibility of neuronal current detection using LF-NMR. In addition to that, necessary preliminary subject studies examining somatosensory evoked neuronal currents are presented. During the phantom study, the influences of two different neuronal time signals on (1)H-NMR signals were observed. The measurements were carried out by using a head phantom with an integrated current dipole to simulate neuronal activity. Two LF-NMR methods based on a DC and an AC (resonant) mechanism were utilized to study the feasibility of detecting both types of magnetic brain signals. Measurements were made inside an extremely magnetically shielded room by using a superconducting quantum interference device magnetometer system. The measurement principles were validated applying currents of higher intensity than those typical of the neuronal currents. Through stepwise reduction of the amplitude of the current dipole strength, the resolution limits of the two measuring procedures were found. The results indicate that it is necessary to improve the signal-to-noise ratio of the measurement system by at least a factor of 38 in order to detect typical human neuronal activity directly by means of LF-NMR. In addition to that, ways of achieving this factor are discussed.


Subject(s)
Brain Mapping/methods , Brain/physiology , Evoked Potentials, Somatosensory/physiology , Magnetic Resonance Spectroscopy/methods , Brain Mapping/instrumentation , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
3.
Biomed Tech (Berl) ; 56(2): 91-7, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21446889

ABSTRACT

Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.


Subject(s)
Algorithms , Brain/physiology , Diagnosis, Computer-Assisted/methods , Evoked Potentials, Somatosensory/physiology , Magnetoencephalography/methods , Adult , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL