Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Pediatr ; 10: 944813, 2022.
Article in English | MEDLINE | ID: mdl-35874565

ABSTRACT

During fetal life some cardiac defects may lead to diminished left heart growth and to the evolution of a form of hypoplastic left heart syndrome (HLHS). In fetuses with an established HLHS, severe restriction or premature closure of the atrial septum leads to left atrial hypertension and remodeling of the pulmonary vasculature, severely worsening an already poor prognosis. Fetal therapy, including invasive fetal cardiac interventions and non-invasive maternal hyperoxygenation, have been introduced to prevent a possible progression of left heart hypoplasia, improve postnatal outcome, or secure fetal survival. The aim of this review is to cover patient selection and possible hemodynamic effects of fetal cardiac procedures and maternal hyperoxygenation in fetuses with an evolving or established hypoplastic left heart syndrome.

2.
Isotopes Environ Health Stud ; 57(1): 35-52, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32972262

ABSTRACT

Micropollutants are frequently detected in groundwater. Thus, the question arises whether they are eliminated by natural attenuation so that pesticide degradation would be observed with increasing residence time in groundwater. Conventional analytical approaches rely on parent compound/metabolite ratios. These are difficult to interpret if metabolites are sorbed or further transformed. Compound-specific stable isotope analysis (CSIA) presents an alternative for identifying degradation based on the analysis of natural isotope abundances in pesticides and their changes during degradation. However, CSIA by gas chromatography-isotope ratio mass spectrometry is challenged by the low concentrations (ng/L) of micropollutants in groundwater. Consequently, large amounts of water need to be sampled requiring enrichment and clean-up steps from interfering matrix effects that must not introduce artefacts in measured isotope values. The aim of this study was to evaluate the accuracy of isotope ratio measurements of the frequently detected micropollutants atrazine, desethylatrazine and 2,6-dichlorobenzamide after enrichment from large water volumes (up to 100 L) by solid-phase extraction with consecutive clean-up by HPLC. Associated artefacts of isotope discrimination were found to depend on numerous factors including organic matter content and extraction volume. This emphasizes the necessity to perform a careful method evaluation of sample preparation and sample pre-treatment prior reliable CSIA.


Subject(s)
Atrazine/analysis , Benzamides/analysis , Chemical Fractionation/methods , Groundwater/chemistry , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Gas Chromatography-Mass Spectrometry/methods , Isotopes/analysis , Limit of Detection , Solid Phase Extraction/methods